Attach the scanning lamp so that its light-emitting portion (open side) is to the left
when viewed from the front of the copier as shown in Figure 2-20.
Figure 2-20 (front view)
Caution:
Do not touch the fluorescent lamp. (Use rint-free paper)
Be sure to adjust the gain and AE whenever you have replaced the fluorescent
lamp. (See P. 2-7.)
•
Make sure that the cut-off of the fluorescent heater is correctly oriented in relation
to the intensity adjustment sensor.
Figure 2-21
Reference:
The fluorescent lamp heater will not operate unless the copier’s heater switch is
turned on.
CHAPTER 2 STANDARDS AND ADJUSTMENTS
2-15
Light-emitting portion
Light adjustment sensor
Fluorescent lamp heater