4-22
MultiPASS MP730/MP700 Chapter 4: Maintenance and Service
No.
Tx or Rx
Definition
##768
[TX]
In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded or a T5 time-over (60 sec)
condition occurred after transmission of PPS-EOP
##769
[TX]
In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded after transmission of PPS-EOP
##770
[TX]
In ECM transmission, no significant signal can be received after
transmission of EOR-NULL, and the allowed number of
procedure signal re-transmissions was exceeded
##772
[TX]
In ECM transmission, DCN was received after transmission of
EOR-NULL
##773
[TX]
In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded or a T5 time-over (60 sec)
condition occurred after transmission of EOR-NULL
##774
[TX]
In ECM transmission, ERR was received after transmission of
EOR-NULL
##775
[TX]
In ECM transmission, no significant signal can be received after
transmission of EOR-MPS, and the allowed number of
procedure signal re-transmissions was exceeded
##777
[TX]
In ECM transmission, DCN was received after transmission of
EOR-MPS
##778
[TX]
In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded or a T5 time-over (60 sec)
condition occurred after transmission of EOR-MPS
##779
[TX]
In ECM transmission, ERR was received after transmission of
EOR-MPS
##0780
[TX]
In ECM transmission, no significant signal can be received after
transmission of EOR-EOM, and the allowed number of
procedure signal re-transmissions was exceeded
##782
[TX]
In ECM transmission, DCN was received after transmission of
EOR-EOM
##783
[TX]
In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded or a T5 time-over (60 sec)
condition occurred after transmission of EOR-EOM
##784
[TX]
In ECM transmission, ERR was received after transmission of
EOR-EOM
##785
[TX]
In ECM transmission, no significant signal can be received after
transmission of EOR-EOP, and the allowed number of
procedure signal re-transmissions was exceeded
##787
[TX]
In ECM transmission, DCN was received after transmission of
EOR-EOP
##788
[TX]
In ECM transmission, the allowed number of procedure signal re-
transmissions was exceeded or a T5 time-over (60 sec) condition
occurred after transmission of EOR-EOP
Содержание MP 700
Страница 1: ...MP 700 MP 730 SERVICE MANUAL Canon ...
Страница 8: ...Chapter 1 General Description ...
Страница 23: ...1 15 MultiPASS MP730 MP700 Chapter 1 General Description 3 OVERVIEW 3 1 External View Figure 1 5 External View ...
Страница 24: ...1 16 MultiPASS MP730 MP700 Chapter 1 General Description 3 2 Operation Panel Figure 1 6 Operation Panel 1 ...
Страница 27: ...Chapter 2 Technical Reference ...
Страница 37: ...2 10 MultiPASS MP730 MP700 Chapter 2 Technical Reference 4 NEW FUNCTION There is no new function in this model ...
Страница 38: ...Chapter 3 Assembly and Disassembly ...
Страница 64: ...3 26 MultiPASS MP730 MP700 Chapter 3 Assembly and Disassembly This page intentionally left blank ...
Страница 65: ...Chapter 4 Maintenance and Service ...
Страница 128: ...4 63 MultiPASS MP730 MP700 Chapter 4 Maintenance and Service Figure 4 29 System Data List 2 8 ...
Страница 129: ...4 64 MultiPASS MP730 MP700 Chapter 4 Maintenance and Service Figure 4 30 System Data List 3 8 ...
Страница 130: ...4 65 MultiPASS MP730 MP700 Chapter 4 Maintenance and Service Figure 4 31 System Data List 4 8 ...
Страница 131: ...4 66 MultiPASS MP730 MP700 Chapter 4 Maintenance and Service Figure 4 32 System Data List 5 8 ...
Страница 132: ...4 67 MultiPASS MP730 MP700 Chapter 4 Maintenance and Service Figure 4 33 System Data List 6 8 ...
Страница 133: ...4 68 MultiPASS MP730 MP700 Chapter 4 Maintenance and Service Figure 4 34 System Data List 7 8 ...
Страница 140: ...Chapter 5 Appendix ...