(8/34)
Cycles
of LED
blinking
Error
Error
code
*1
Check points & Solution
Parts to be replaced if
the listed solutions
are not effective
9 times EEPROM error
[6800]
[6801]
P09 (1) Part replacement:
-> Replace the logic board ass'y.
- Logic board ass’y
10 times VH monitor error [B200] P10 (1) Head contact pin condition of the carriage unit:
-> Remove any foreign material.
If the pin is smeared, bent, or deformed,
replace the carriage unit.
(2) If the error still occurs:
-> Replace the part(s) listed on the right (under
“Parts to be replaced if the listed solutions are
not effective”).
- Ink cartridge
- Logic board ass’y
- AC adapter
22 times Scanner error
[5011]
[5012]
P22 (1) Scanner flexible cable conditions (wrong or
imperfect connection, connection at an angle,
damage, etc.):
-> Re-connect the cable.
If the cable is damaged, replace the scanner
unit.
(2) If the error still occurs:
-> Replace the part(s) listed on the right (under
“Parts to be replaced if the listed solutions are
not effective”).
-Scanner unit
- Logic board ass’y
26 times Network related
error
(MG3100 series,
MG3200 series,
MG4100 series,
MG4200 series
only)
[690#]
[691#]
P26 (1) WLAN flexible cable condition (wrong or imperfect
connection, connection at an angle, damage,
etc.):
-> Re-connect the cable.
If the cable is damaged, replace it. Note that
the WLAN flexible cable is not designated as a
service part.
(2) If the error still occurs:
-> Replace the part(s) listed on the right (under
“Parts to be replaced if the listed solutions are
not effective”).
- WLAN unit
- Logic board ass’y
Note: The WLAN unit is
not designated as
a service part.
27 times USB related
error
[693#] P27
-> Power off the machine, and power it on again.
If the error still occurs, replace the part listed
on the right (under “Parts to be replaced if the
listed solutions are not effective”).
- Logic board ass’y
28 times USB sub-system
firmware error
[694#]
except
6942
P28
29 times USB sub-system
timeout error
[6942] P29