LBP3100 / LBP3010B
Host machine carries the following 3 functions to prevent the fixing heater from overheating.
- Protective function by CPU
- Protection function by fixing heater safety circuit
- Protection function by temperature fuse
Each function is described as below.
1) Protective function by CPU
CPU of engine controller monitors the thermistor (TH1) temperature consistently.
When TH1 reaches approx 230 deg C, CPU determines that the fixing heater is overheating and stops the fixing heater drive signal(FSRD) output and also turns
OFF relays to shut the power supply to fixing heater.
2) Protection function by fixing heater safety circuit
Fixing heater safety circuit monitors the thermistor (TH1) temperature consistently.
When TH1 reaches approx 235 deg C, it determines that the fixing heater is overheating and the fixing heater safety circuit turns OFF the relay drive circuit to
shut the power supply to the fixing heater.
3) Protection function by temperature fuse (TP1)
When the fixing heater temperature rises abnormally and temperature fuse (TP1) temperature reaches approx 226 deg C, TP1 opens to shut the power supply to
the fixing heater.
2.8.2.2.2 Error detection
0019-7678
LBP3100 / LBP3010B
CPU of engine controller determines the fixing assembly error and shuts the fixing heater drive signal (FSRD) and also turns OFF relays to shut the power supply
to the fixing heater in the following cases. Also, it notifies the error status to the main controller simultaneously.
1) Startup error detection
- When thermistor temperature does not reach 35 deg C within 1.5 sec from heater ON.
- When the thermistor detects the temperature of 100 deg C or below during stand-by.
2) Abnormal low temperature error
- After heater ON, when the thermistor detects the temperature of 100 deg C or below at printing after the thermistor temperature reaches 50 deg C.
- After heater ON, when the thermistor detects the temperature of 55 deg C or below at sheet interval or in cleaning mode after thermistor temperature reaches
50 deg C.
3) Overheat error
When the thermistor detects the temperature of 220 deg C or over 30 times consecutively.
4) Frequency detection circuit error (200-240V series only)
When it cannot detect the frequency detection signal at fixing drive circuit even once within 3.3 sec after power ON.
2.8.2.2.3 Protective Function of Fixing Unit
0025-1178
LBP6000 / LBP6000B
Host machine carries the following 3 functions to prevent the fixing heater from overheating.
- Protective function by CPU
- Protection function by fixing heater safety circuit
- Protection function by temperature fuse
Each function is described as below.
1) Protective function by CPU
CPU of engine controller monitors the thermistor (TH1) temperature consistently.
When TH1 reaches approx 220 deg C, CPU determines that the fixing heater is overheating and stops the fixing heater drive signal(FSRD) output and also turns
OFF relays to shut the power supply to fixing heater.
2) Protection function by fixing heater safety circuit
Fixing heater safety circuit monitors the thermistor (TH1) temperature consistently.
When TH1 reaches approx 235 deg C, it determines that the fixing heater is overheating and the fixing heater safety circuit turns OFF the relay drive circuit to
shut the power supply to the fixing heater.
3) Protection function by temperature fuse (TP1)
When the fixing heater temperature rises abnormally and temperature fuse (TP1) temperature reaches approx 226 deg C, TP1 opens to shut the power supply to
the fixing heater.
2.8.2.2.4 Error detection
0025-1179
LBP6000 / LBP6000B
Resolution Settings
This machine has 2 types of resolution settings (600 x 600 dpi, 600 x 400dpi).
This setting can be changed by whether or not ticking the item on finish settings (Finishing > Process Option > Use output adjustment mode).
600 x 400dpi is specified as factory settings. Ticking this box changes it to 600 x 600dpi.
Содержание LBP6000 Series
Страница 1: ...Sep 8 2010 Service Manual LBP6000 6018 3010 3100 3150 Series...
Страница 2: ......
Страница 6: ......
Страница 12: ...Contents...
Страница 13: ...Chapter 1 PRODUCT DESCRIPTION...
Страница 14: ......
Страница 16: ......
Страница 28: ......
Страница 29: ...Chapter 2 TECHNICAL REFERENCE...
Страница 30: ......
Страница 74: ......
Страница 75: ...Chapter 3 DISASSEMBLY AND ASSEMBLY...
Страница 76: ......
Страница 119: ...Chapter 4 MAINTENANCE AND INSPECTION...
Страница 120: ......
Страница 122: ......
Страница 126: ......
Страница 127: ...Chapter 5 TROUBLESHOOTING...
Страница 128: ......
Страница 130: ......
Страница 137: ...Chapter 6 APPENDIX...
Страница 138: ......
Страница 140: ......
Страница 144: ......
Страница 145: ...Sep 8 2010...
Страница 146: ......