2
2. Troubleshooting
2.1 When an Error Code is Displayed
[Remedy]
•
Check for any abnormalities in the mounting of probable faulty parts or connector connections referring to the table below.
•
Try replacing probable faulty parts referring to the table below.
[NOTE]
•
Error codes are displayed on the LCD Monitor.
•
Adjustments must be performed after the part has been replaced. For details, see the "Adjustments" chapter.
Error Code
E01
E02
E03
E04
E09
E10
E14
E16
E18
E23
Name
AE TIME OUT
AF TIME OUT
EF TIME OUT
AWB TIME OUT
JPEG DMA TIME
OUT
JPEG IC ERROR
UNKNOWN
IMAGING TIME
OUT
ZOOM LENS
ERROR
MEMORY CARD
NO SPACE
Occurrence Conditions
AE processing does not end within the specified time.
AF processing does not end within the specified time.
The focus lens is not driven.
Auto Flash Control does not end within the specified
time.
AWB processing does not end within the specified time.
JPEG processing does not end within the specified time.
JPEG compression processing does not end within
the specified time.
When an error of unknown cause occurs.
When communication between CPU and peripheral
IC is not completed within the specified time during
recording using EVF or after completion of recording.
Movement of the lens barrel does not end within
the specified time.
When the Memory Card becomes full during writing
of photographed images to Memory Card, writing
is repeatedly performed with the JPEG compression
ratio successively increased to reduce the size of the
image file until it can be successfully written to Memory
Card. This error occurs when writing of the JPEG
image file fails after 10 times.
Cause and Probable Faulty Part
MAIN PCB ASS'Y
MAIN PCB ASS'Y
OPTICAL UNIT
MAIN PCB ASS'Y
OPTICAL UNIT
MAIN PCB ASS'Y
OPTICAL UNIT
MAIN PCB ASS'Y
MAIN PCB ASS'Y
MAIN PCB ASS'Y
NKNOWN
MAIN PCB ASS'Y
MAIN PCB ASS'Y
OPTICAL UNIT
MAIN PCB ASS'Y
MAIN PCB ASS'Y
DC/DC PCB ASS'Y
MAIN PCB ASS'Y
MEMORY CARD
E24
E26
E27
POWER ON
ERROR
CAPTURE TIME
OUT
MEMORY WRITE
TIME OVER
The power of the imaging circuit on the MAIN PCB
ASS'Y is not detected.
Writing of the photographed image to SDRAM does
not end within the specified time.
Data form the buffer was not written to the Memory
Card within the specified time.
MAIN PCB ASS'Y
E52
QUICK REVIEW
ERROR
Review of the photographed image failed.
Содержание Ixy Digital 90
Страница 1: ......
Страница 11: ...7 2 2 6 view Diagram IXY DIGITAL 90 Unit mm inch Nominal Dimensions 91 6 3 61 19 6 0 77 56 8 2 24 ...
Страница 12: ...8 IXY DIGITAL 10 85 9 3 38 19 4 0 76 53 5 2 11 Unit mm inch Nominal Dimensions ...
Страница 13: ...9 2 3 Nomenclature IXY DIGITAL 90 ...
Страница 14: ...10 IXY DIGITAL 10 ...
Страница 132: ...16 8 When the message on the right appears click the FINISH button This ends the CCD Adjustment ...
Страница 134: ...18 4 When the message on the right appears click the FINISH button This ends the Shading Adjustment ...
Страница 144: ...28 4 When the message on the right appears click the FINISH button This ends the Flash Adjustment ...
Страница 155: ...01 Feb 2007 CANON INC 2007 2 6 OPERATION FPC ASS Y IXY DIGITAL 90 DIGITAL IXUS 75 PowerShot SD750 Secondary Side ...
Страница 157: ...01 Feb 2007 CANON INC 2007 2 8 BATTERY FPC ASS Y IXY DIGITAL 90 DIGITAL IXUS 75 PowerShot SD750 Secondary Side ...
Страница 163: ...01 Feb 2007 CANON INC 2007 2 14 OPERATION FPC ASS Y IXY DIGITAL 10 DIGITAL IXUS 70 PowerShot SD1000 Secondary Side ...
Страница 165: ...01 Feb 2007 CANON INC 2007 2 16 BATTERY FPC ASS Y IXY DIGITAL 10 DIGITAL IXUS 70 PowerShot SD1000 Secondary Side ...
Страница 166: ......