Measure against E674-0100
[Symptom]
E674-0100 may occur when FAX clearing and job canceling are executed.
[Cause]
When a job manipulation such as FAX job cancelation is executed just after the performance of All CLEAR of FAX (Service Mode
> Mode List > FAX > Clear > ALL) in a state that FAX jobs still remain, the data inconsistencies of FAX history data are detected
at the time of turning ON/OFF main power supply of the engine and then that results in the above symptom.
[Service work]
When E674-0100 continuously occurs even the main power supply of engine has been turned OFF/ON , execute again "Service
Mode > Mode List > FAX > Clear > ALL" and then turn OFF/ON the main power supply without job manipulations.
[Caution]
Make sure that no FAX job remains when executing ALL CLEAR of FAX.
Previous FAX communication information will be deleted when turning OFF/ON the main power supply after the FAX CLEAR.