Boss breakage in the shutter of patch sensor assembly occurring
when opening/closing the shutter
[Symptom]
In the machines prior to the Countermeasure cut-in serial number in factory described below when opening the shutter [2] in the
patch sensor assembly [1], the boss [a] which acts as a supporting point may break.
[Cause]
Stress caused by opening and closing the shutter applies to the root of the boss intensively for a long time, resulting in the above
symptom.
[Service work]
When the above symptom occurs, refer to Service Manual and replace with the new type patch sensor assembly (FM3-7298-010)
and the shutter (FC8-9669-010).
[Service parts]
• FC8-9669 SHUTTER
• FM3-7298 PATCH SENSOR ASS'Y
[Countermeasure cut-in serial numbers in factory]
- iR-ADV 8105/8205 Series : No implemented due to production discontinuance.
Model
Serial number
iR-ADV 8505 230V AS
SWD00552
iR-ADV 8505 230V EUR
SWC00746
iR-ADV 8505P 230V EUR
TMF00504
iR-ADV 8505i 120V USA
SWA00993
iR-ADV 8585i 120V USA
SWN00689
iR-ADV 8505i 120V USA G
SWB00501
32
Содержание imageRUNNER ADVANCE 8500 series
Страница 1: ...Troubleshooting Guide imageRUNNER ADVANCE 8500 6500 Series April 2018 OIP Field Quality Assurance Div ...
Страница 37: ...iR ADV 8585i 120V USA G SWP00501 iR ADV 8505 220V CN SWE00105 33 ...
Страница 53: ...4 5 Make some prints and check that the above issue does not occur 49 ...
Страница 66: ...2 Remove the grate shaped lower guide 2 screws 2 62 ...
Страница 70: ...7 Reattach the metal plate 1 Screw 2 x1 8 Loosen the 2 screws 1 66 ...
Страница 74: ...iR ADV 8505 220V CN To be informed as soon as identified 70 ...
Страница 90: ... Service parts FM4 0889 010 solenoid assembly 86 ...