[Service work]
1) Check to see if the following 4 connectors are not disconnected.
If no connector is disconnected, check other factors (disconnection of cable and unit etc.)
[Reference] Refer to Parts Replacement and Cleaning > "Removing the DC Controller PCB", "Removing Main Controller PCB 2"
and "Removing the Power Supply Assembly" in the service manual to get access to respective PCBs.
1-1) See if the connectors J401 and J442 of the DC controller PCB are not disconnected.
1-2) See if the connector J5202 of the main controller PCB 2 is not disconnected.
1-3) See if the connector J518 of the relay PCB is not disconnected.
2) Start the main body and confirm that a phenomenon does not occur.