Canon
imagePRESS V900/V800/V700 Customer Expectations Document
Revision 2
imagePRESS V900/V800/V700 Customer Expectations Document
Page 64
Power Requirements (cont’d)
Part or Accessory
Power Supply
Power Supply Cord/Plug
Specifications
Length of Power
Cord
Plockmatic BLM50/BLM35
1-100-230V (±10%) AC,
50-60 Hz
NEMA 5-15
6’ (1.8 m)
Trimmer FTR50
From the Plockmatic
BLM50/BLM35 Professional
Booklet Maker
—
—
Cover Feeder CF50
Booklet Fold BF50
Rotate Crease Trimmer
BCT50
1-100-230V (±10%) AC,
50-60 Hz
NEMA 5-15
6’ (1.8 m)
High Capacity Belt Stacker
BST4000-1
1-100-240V (+6%, -10%) AC,
50-60 Hz, 1A
NEMA 5-15
6’ (1.8 m)
Plockmatic Multi-Purpose
Stacker
1-100-240V AC, 50/60 Hz,
2A
NEMA 5-15
Inspection Unit-B1
1-100-240V AC, 50/60Hz,
1.4A
NEMA 5-15
6.2’ (1.9 m)
Sensing Unit-B1
1-100-240V AC, 50/60Hz,
2.5A
NEMA 5-15
6.2’ (1.9 m)
IMPORTANT
•
Phase converters and step-down transformers are not supported.
•
We recommend an additional standard 115 V/15 A receptacle for service tools,
such as a laptop computer or vacuum that may be used when servicing or
configuring the machine.
•
Use only dedicated and properly grounded receptacles for the main unit and
imagePRESS Servers.
•
Do not use extension cords. The ground connection serves to provide the internal
electronics with a reference voltage. Faulty or poor ground sources will cause
this reference voltage to fall into a range that no longer serves as a reliable
reference voltage. The internal logic and programming of the imagePRESS
V900/V800/V700 will not perform reliably because there is an insufficient
difference between the internal operating signal voltages and the poor ground
reference signal. A qualified electrician can measure and provide the ground
source that the imagePRESS V900/V800/V700 or any computer controlled office
equipment requires.
•
Before installation, confirm that all necessary receptacles are available.
23 Canon USA strongly suggests that the power receptacle for the BLM 50/35 Professional Booklet Maker is connected to a
separate breaker from the power receptacle for the Rotator Module. This is necessary to maintain adequate current for the
Professional Booklet-Maker and each of the modules.
24 Also requires two 120-127 V AC, 60Hz power outlets for Inspection Tool (Workstation) and Monitor.