Canon
imagePRESS C7011VPS/C6011VPS/C6011S Service Guide
IMPORTANT
•
We recommend an additional standard 120 V/15 A outlet for service
tools, such as a laptop computer or vacuum that may be used when
servicing or configuring the machine.
•
Use only dedicated and properly grounded outlets for the main unit and
PRISMAsync Controllers. It is also strongly suggested to use dedicated
and properly grounded outlets for each optional accessory. Do not use
extension cords. The ground connection serves to provide the internal
electronics with a reference voltage. Faulty or poor ground sources will
cause this reference voltage to fall into a range that no longer serves as
a reliable reference voltage. The internal logic and programming of the
imagePRESS C7011VP Series machines will not perform reliably
because there is an insufficient difference between the internal operating
signal voltages and the poor ground reference signal. A qualified
electrician can measure and provide the ground source that the
imagePRESS C7011VPs Series machines or any computer controlled
office equipment requires.
•
Before installation, confirm that all necessary receptacles are available.
•
Phase converters and step down transformers are not supported
Table 21 – Power and Plug Requirements Rear View
imagePRESS C7011VPS/C6011VPS/C6011S Rear View
(Note: Phase converters and step down transformers are not supported)
imagePRESS C7011VPS/C6011VPS/C6011S Service Guide
January 2015
Revision 3
Page 29