7
7
7-4
7-4
Error Codes > Jam Codes
Error Codes > Jam Codes
Code
Detection description
Remedy
E736 0000
Communication error
with CCU/modem, or no
FAX board installed on
FAX model.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Check the connection of connectors between the Main
Controller Board (J601, J602) and the FAX-NCU Board
(J1201, J1204).
(2) Replace the connectors between the Main Controller
Board (J601, J602) and the FAX-NCU Board (J1201,
J1204).
(3) Replace the FAX-NCU Board.
(4) Replace the Main Controller Board.
E740 0002
Error detection on either
Network Board or Mac
address
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Check the connection of the network cable.
(2) Replace the Main Controller Board.
E744
0002 Language file error
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
Update the set of the Controller Firmware
4000
Engine ID error (Invalid
engine connection is
detected)
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Check the DC Controller Board.
(2) Update the Engine Firmware.
(3) Update the set of the Controller Firmware
6000
Communication error
with Wireless LAN
board.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Replace the Wireless LAN Board.
(4) Replace the Main Controller Board.
E806 0000
Fan Motor cannot rotate
at specified revolution
speed.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Replace the Main Fan Unit.
(2) Replace the DC Controller Board.
E808 0001 Fixing Assembly_Edge
Left Cooling Fan error
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Replace the Edge Left Cooling Fan.
(2) Replace the DC Controller Board.
E808 0002 Fixing Assembly_Edge
Right Cooling Fan error
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Replace the Edge Right Cooling Fan.
(2) Replace the DC Controller Board.
T-7-2
Jam Codes
Jam Codes
Cause
Scanner Jam Codes
0001H
Non-DES sensors.
0002H
DES Sensor Stationary
0094H
Initial Stationary
0095H
Pickup NG
0071H
Timing error
Printer Jam Codes
0004H
Re-pickup Delay Jam
0005H
Multi-purpose tray pickup delay jam
0008H
Pickup Stationary Jam
000CH
Fixing Delivery Delay Jam
0010H
Fixing Delivery Stationary Jam
0014H
Internal Paper Jam
0018H
Door Open Jam
001CH
Wrap Jam
0020H
Reversal Delay Jam
0021H
Reversal Stationary Jam
T-7-3
Содержание i-SENSYS MF211 Series
Страница 11: ...1 1 Product Overview Product Overview Product Lineups Features Product Specifications Name of Parts ...
Страница 60: ...3 3 Periodical Services Periodical Services Periodically Replaced Parts Consumables Periodical Service ...
Страница 255: ...5 5 Adjustment Adjustment Mechanical Adjustment ...
Страница 257: ...6 6 Trouble Shooting Trouble Shooting Test Print Trouble Shooting Items Log Collector Version Upgrade ...
Страница 270: ...7 7 Error Codes Error Codes Overview Error Codes Jam Codes ...
Страница 274: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE NETWORK ...