4
4
4-91
4-91
Disassembly/Assembly > External Cover/Internal System (Duplex Model) > Removing the Duplex Feed Guide Unit. (Duplex Model) > Procedure
Disassembly/Assembly > External Cover/Internal System (Duplex Model) > Removing the Duplex Feed Guide Unit. (Duplex Model) > Procedure
NOTE: How to assemble the Delivery Tray
1) Pass the Cartridge Arm [1] through the hole [A] of the Upper Cover Unit.
2) Install the Cartridge Arm [1] and the 2 Fixing Pressure Arms [2] to the Delivery Tray [3].
[3]
[2]
[1]
[2]
[A]
F-4-240
Removing the Duplex Feed Guide Unit. (Duplex Model)
■
Preparation
1) Remove the Left Cover (Duplex Model) (Refer to page 4-86).
2-1) Remove the DADF Unit + Reader Unit (DADF Model) (Refer to page 4-27).
2-2) Remove the SADF Unit + Reader Unit (SADF Model) (Refer to page 4-51).
2-3) Remove the Copyboard Cover + Reader Unit (Copyboard Model) (Refer to page 4-76).
3) Remove the Right Cover (Duplex Model) (Refer to page 4-87).
4) Remove the Front Cover Unit (Duplex Model) (Refer to page 4-89).
5) Remove the Upper Cover Unit (Duplex Model) (Refer to page 4-89).
■
Procedure
1) Remove the Duplex Guide [1].
• 2 Claws [2]
2x
[1]
[2]
F-4-241
F-4-242
Содержание i-SENSYS MF211 Series
Страница 11: ...1 1 Product Overview Product Overview Product Lineups Features Product Specifications Name of Parts ...
Страница 60: ...3 3 Periodical Services Periodical Services Periodically Replaced Parts Consumables Periodical Service ...
Страница 255: ...5 5 Adjustment Adjustment Mechanical Adjustment ...
Страница 257: ...6 6 Trouble Shooting Trouble Shooting Test Print Trouble Shooting Items Log Collector Version Upgrade ...
Страница 270: ...7 7 Error Codes Error Codes Overview Error Codes Jam Codes ...
Страница 274: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE NETWORK ...