83
Error Messages
Error Messages
Message
Description and Action
Calibration
Failed to initialize the external sensor.
See CA-310 and CA-210 instruction manual.
Calibration error.
• Check the installation and connection of the
external sensor and retry (
• Perform matrix calibration of CA-310 and CA-210
(
Calibration is completed.
(Brightness setting is lower than target brightness.)
Set the "Luminance" in calibration again (
Failed to detect the external sensor.
Please check the connection with the sensor.
Correctly connect the external sensor to the USB
port of this main unit.
Network
Communication error.
IP address may be in conflict or there may be a
network communication error. Check the network
environment.
Invalid IP Address.
Enter the correct IP address.
Invalid Subnet Mask.
Enter the correct subnet mask.
Various settings,
CDL export
The USB memory is full.
Use another USB memory or delete the content of
the memory.
Failed to write file.
The USB memory may be defective or protected.
Check the USB memory.
LUT, Various settings,
CDL import
(LUT Import) "LUT Type" is different.
(CDL Import) "File Type" is different.
Select the correct file format.
Failed to read file.
The USB memory may be defective or protected.
Check the USB memory.
Failed to import.
There is an error in the file to be imported. Check the
file.
No import file.
Check to see if the file has been imported to the
USB memory.
Screen
Capture
Failed to capture.
The USB memory may be defective or protected.
Check the USB memory.
Invalid Signal.
A screen displaying no video is being captured for
example there is no signal or an unsupported signal
is being input. Check the signal, input it again, and
capture it.
Copy protected signal.
The signal you tried to capture may be protected by
HDCP 2.2 which is a copy prevention standard for
HDMI. In this case, the signal cannot be captured.
Check the HDMI signal.
Failed to playback file.
The USB memory may be defective or protected.
Check the USB memory.