CHAPTER 3
3 - 9
COPYRIGHT
2002 CANON INC. CANOSCAN 8000F REV.0 OCT. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
q
Flat Cable
w
Button Cable Connector
e
Motor Unit Cable Connector
r
Main PCB
2) Disconnect the motor unit cable and button cable from the main PCB, and turn the main
PCB over as shown in Figure 3-8.
Figure 3-8
3) Disconnect the flat cable from the main PCB.
1
3
2
4
B. Removing the Button PCB
1) Remove the film adapter unit, top cover, document glasss unit, and front panel.
2) Remove five screws from the button PCB to remove it.