62
Problem:
Scan button cannot be selected
➤
Solution 1: A scan cannot be performed if the scan area is set too small (less
than 64 x 64 pixels). Increase the size of the scan area
➤
Solution 2: A scan cannot be performed unless a scan area is specified. Specify a
scan area
➤
Solution 3: A scan cannot be performed if the required memory is larger than
the free memory. Change the resolution
(
➜
p. 19)
or scan area
(
➜
p. 30)
until the required memory is lower
Problem:
The “Insufficient Memory” error message appears when
scanning
➤
Solution 1: Select the smallest possible area and rescan
➤
Solution 2: Lower the resolution and magnification settings for the output
device to the lowest possible values
(
➜
p. 19)
➤
Solution 3: Rescan after closing all the application programs other than the one
used to start Plug-in Module CS-U
➤
Solution 4: Rescan after you have restarted the application program used to
start Plug-in Module CS-U
➤
Solution 5: Quit the application program used to start Plug-in Module CS-U and
increase the memory allocated to it. Click the application program
icon once. Then open the [File] menu, choose [Get Info], and choose
[Memory] from the submenu. Increase the memory in the Preferred
Size box to at least 16,000 K.
➤
Solution 6: Increase the amount of RAM as required
Problem:
The [Image] menu [ColorSync] option cannot be used in
Plug-in Module CS-U
➤
Solution:
ColorSync is not recognized after Mac OS upgraded to Version 9
after Plug-in Module CS-U was installed onto Mac OS 8.6. Reinstall
Plug-in Module CS-U
(
➜
p. 6)