Please read this manual before installing and using the heater.

SAFETY WARNINGS

What to do if you smell gas

1. Turn OFF the main gas supply.
2. Extinguish any open flame.
3. Open windows.
4. Do not touch electrical switches.
5. Do not use your telephone.
6. Call your gas supplier immediately from a neighbour’s phone.

Warnings

1. Improper installation, adjustment, alteration, service or maintenance can cause 

injury or property damage. Refer to the sections of this manual for correct 
procedures, or consult with place of purchase, a licensed plumber, a gas supplier 
or the CANNON distributor listed in this manual.

2. Install the heater only in locations that are referred to in the installation instructions. 

Do not build the heater into bookcases, walls or enclosures without the use of a 
Mock Fireplace kit if appropriate for that type of installation.

3. Due to high temperatures the room heater should be located out of traffic and away 

from:

Furniture and draperies
Combustible materials
Gasoline and other flammable liquids

    Do not place clothing or other flammable material on or near the heater.

4. Keep curtains*, clothes, furniture and other flammable materials at least 

900mm from front and sides of heater.

* At the owner’s discretion curtain clearance can be less than 900mm as 

long as they are restrained from the front, top and sides of the heater. The 
manufacturer takes no responsibility if curtain clearance is less than 900mm 
and not restrained.

5. Children and adults should be alerted to the hazard of high surface temperature 

and should take care to avoid burns or clothing ignition.

This appliance is not intended for use by persons (including children) with reduced 
physical, sensory or mental capabilities or lack of experience and knowledge, 
unless they have been given supervision or instruction concerning use of the 
appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.

6. Never attempt to burn paper or any other material in the heater.

7. Do not place articles on or against this appliance.

Do not use or store flammable materials near this appliance.
Do not spray aerosols in the vicinity of this appliance while it is in operation.
Do not modify this appliance.

notes

TO REPLACE THE 
COMBUSTION FAN

The Combustion Fan is accessed from the rear of the heater. 
Therefore to replace the combustion fan the heater must be 
removed from the fireplace. The flue terminal may need to be 
removed from the flue hoses to allow the heater to be moved.

          1. Disconnect combustion fan wiring from loom.

          2. Remove the  rear cover.

          3. Remove the four (4) screws securing the fan to fan duct.  
    
          4. Remove fan assembly from fan duct.

          5. Replace in reverse to disassembly.

TO REMOVE THE BURNER 
AND ELECTRODES

TO REPLACE TYPE “X”
CORD

1.

 Remove the front mesh cover.

2.     Slacken off the glass clamp screws and remove the 
       top and one side clamp.
3.    Follow fig 25. of the installation instructions
       for glass removal.
4.    Remove the logs from the burner chamber.
5.     Remove the inspection hatch cover.
6.    Disconnect supply pipe nut from the burner manifold.
7.    Remove the electrode connections from the spark 
       module.
8.   Release gland seal retaining nut.
9.   Remove burner fixing brackets (2) from rh and lh 
       sides of the burner. lift the burner assembly upwards
       and carefully remove from the burner chamber.
10.  Pull electrode leads from the gland seal.
11.  Replace in reverse order.

1. 

 

CONTACT SAMPFORD

IXL

 SERVICE DEPARTMENT AND QUOTE CORD

    

 

PART NUMBER  

F2799.

SERVICE INSTRUCTIONS

24

5

FIG 31.

The  Cannon  appliance  is  warranted  against  defects  in  materials  and  

Warranty service, which includes parts and labour for the replacement or
repair of defective parts, is available through the CANNON distributor.
(Details below or on page 24).

Consumers are responsible for service person’s travel outside normal 

service areas (approximately seventy (70) kilometer radius from the nearest 

Cannon dealer’s location), local transport costs, or any preventative 
maintenance works as described in 

Any product subjected to misuse, abuse, negligence, accident or alteration 
will have its warranty voided.  The defacement of serial plate will also void 
warranty.

If installation is not carried out in accordance with manufacturer’s 

instructions, this warranty may be void.

The customer must keep their “Tax Invoice” as proof of purchase of this
product and compliance certificate as proof of required installation.

workmanship for a period of two (2) years from its date of original 
purchase, applicable only for residential use in Australia.

this manual.

Enter the details of the date installed and the Compliance Certificate 
number in the appropriate area on the rear page of this manual.

Содержание Fitzroy Powerflue In-built

Страница 1: ...ane gases DON T RISK YOUR APPLIANCE WARRANTY ONLY A LICENSED PERSON WILL GIVE YOU A COMPIANCE CERTIFICATE SHOWING THAT THE WORK COMPLIES WITH ALL THE RELEVANT STANDARDS AND ONLY A LICENSED PERSON WILL...

Страница 2: ...Sealing the fascia Gas connections 16 Log installation 17 Gas control 18 19 Gas pressure point Gas pressure adjustment Trouble shooting 20 21 Service instructions 22 24 General To replace the primary...

Страница 3: ...nty repair or replace free of charge this Cannon appliance or any component part which upon examination by us or our repair agent is found to be defective in materials workmanship or manufacturing How...

Страница 4: ...K BRN 6 WAY CONNECTOR 6 WAY CONNECTOR BLUE 4 WAY F3663 6_B NO PRESSURE SWITCH F3327 COMBUSTION FAN POWER FLUE WIRING DIAGRAM COMMON COMMON 4 WAY 25 Gas type Natural or Propane gas as indicated on data...

Страница 5: ...ith reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible f...

Страница 6: ...of young children or the infirm a second guard is required Standards This appliance meets the following standards When installed correctly Standards Australia AS NZS 3100 AS 5601 AS 4553 2008 1 Remov...

Страница 7: ...300 Appliances over 150 MJ hr input up to 200 MJ hr input 1500 1500 Appliances over 200 MJ hr input 1500 1500 All fan assisted flue appliances in the direction of discharge 1500 k From a mechanical ai...

Страница 8: ...eater will not start no indicator lamps The gas valve should open at the same time as the igniter sparks If there is no gas to the burner when this occurs check the solenoid coils for continuity Check...

Страница 9: ...re a digital multimeter with the functions to measure ac dc voltage Continuity resistance and micro amps It is critical that the appliance is earthed and that the active and neutral are not reversed I...

Страница 10: ...LING MANTLE 300 MIN 1000 MIN CLEARANCE 436 605 610 MIN 485 MIN 695 50 100 710 MIN 160 mm GAS SUPPLY 10 mm 75 mm GAS SUPPLY FLUE DIA 160 mm FLUE TERMINAL INSTALLATION DETAIL For minimum clearances refe...

Страница 11: ...ICATION THROUGH WALL APPLICATION TIMBER or BRICK 1 1 2 2 CONSULT MOCK FIRE INSTRUCTION BOOKLET REQUIREMENTS FOR THIS APPLICATION FLUEING OPTIONS 517 517 25 min 3 8 3 CORNER WALL APPLICATION 1 2 CONSUL...

Страница 12: ...flat and level Using your template as a guide mark the flue cutout on the rear wall of the cavity and cut through from either the inside or the outside to produce a neat round hole in the external wal...

Страница 13: ...ir respective holes It may be advisable when the heater is positioned halfway into cavity to check hoses from outside to ensure that they are not kinked See fig 17 SEALING TAPE APPLIED TO EDGE OF UNIT...

Страница 14: ...clipping points on the rear of the fascia 14 a Place log no 1 onto the 2 front pins on the burner head ensuring that the charring faces the front b Place log no 2 onto the two left back pins c Place l...