Flame characteristics

The heater flames should be stable, not lifting from burner and the logs

should glow after approximately 15 minutes operation on HIGH setting.

The heater has been designed to burn with luminous flames, which mimic

natural log combustion, and may exhibit slight carbon deposition. If heavy

carbon deposits occurs or flames impinge on the roof of the combustion

chamber, turn the appliance off and contact the service agent in your state.

For service to this appliance refer page 19 for contact details.

Cleaning.

All cleaning should be carried out when the heater is cold.  Normally the

heater should only need wiping with a lint - free damp cloth.  Any stubborn

stains can be removed with a non-abrasive spray on cleaner. If an abrasive

cleaner is used the paint finish will be damaged.

For heater fitted with the glass front

All cleaning should be carried out when the heater is cold. Clean the outer

glass with a liquid solution such as ‘Windex’ or similar. Do not use harsh

abrasive cleaners or sharp metal scrapers to clean the heater glass front

since they can scratch the surface, which may result in shattering of the

glass.

Internally the heater should only be cleaned by a licensed service person

listed in this manual.

If your heater requires attention contact your supplier or licensed service

person listed in this manual.

Important:

The appliance should be inspected before use and at least annually by an

authorised service person. More frequent cleaning may be required due to

excessive lint build-up from carpeting, bedding materials, pet hair, etc.

It is imperative that control compartments and circulating air passage ways

of the appliance be kept clean.

Do not use this fire if the glass is cracked or with the glass safety screen

removed.

Do not use fire with broken or missing logs.

17

27

Содержание FITZFS-SDSEB-LP

Страница 1: ...proved for use with Natural and Propane gases Please leave instructions with the owner FITZROY FREESTANDING USER INSTRUCTIONS INSTALLATION INSTRUCTIONS SERVICE INSTRUCTIONS FREESTANDING MODELS FITZFS...

Страница 2: ...g installation Gas control Gas pressure point Installation tips Flue installation 16 17 Flue kit Service instructions 18 20 General To replace primary glass To replace outer glass To replace the gas c...

Страница 3: ...ith manufacturer s instruc tions this warranty may be void The customer must keep their Tax Invoice as proof of purchase of this product and compliance certificate as proof of required installation Mo...

Страница 4: ...ammable material on or near the heater 4 Keep curtains clothing furniture and other flammable materials at least 900mm from front rear and sides of the heater At the owner s discretion curtain clearan...

Страница 5: ...Testing the effectiveness of the flue Before testing the flue confirm air vents are unobstructed If an exhaust fan or other heating appliances are present switch them on This is to test that there is...

Страница 6: ...ol lay out refer to figure 2 3 To turn heater on press switch to POWER ON position There is a 5 second delay before the burner ignites At this setting the burner is on LOW and the fan speed is on LOW...

Страница 7: ...switch for LOW setting Refer figure 7 On low burner setting it is more efficient to operate the fan speed on LOW 8 If the burner fails to ignite wait 20 seconds and repeat the ignition procedure See...

Страница 8: ...heater fitted with the glass front All cleaning should be carried out when the heater is cold Clean the outer glass with a liquid solution such as Windex or similar Do not use harsh abrasive cleaners...

Страница 9: ...essure 1 13 kPa Nat Gas 2 75 kPa Propane Fan 3 speed Controller Electronic direct spark Power requirement 240 VAC 10 Amp Power consumption 90 VA maximum Optional Accessories Silver trim Cathedral ceil...

Страница 10: ...d furnishing refer to warning 3 4 on page 4 For minimum clearances refer fig 9 and 10 4 Remove the carton from the heater and lift from pallet Check that the heater is suitable for the gas available R...

Страница 11: ...e either side Refer figure 12 10 Remove the heater front by pulling it towards you gently to partly disengage it from the body of the heater then gently lift it up vertically to completely disengage i...

Страница 12: ...ront log No 4 Right back log Position the four individually numbered logs in the following order on the burner head as shown in figures 17 20 The male locating pins in the burner head must engage with...

Страница 13: ...rope Check that the gas pressure is correctly adjusted If the heater still does not operate to specification refer to the trouble shooting chart on pages 20 21 or contact Sampford IXL in your state P...

Страница 14: ...clockwise to decrease pressure 20 Switch the heat button back to Low Flame position as indicated in figure 25 a retain spanner in position and using a screwdriver as per figure 25 b adjust the central...

Страница 15: ...service agents please refer page 19 Installation tips Make sure that the heater is fully commissioned and be certain to con duct a test of the integrity of the flue operation taking into account any...

Страница 16: ...s have been observed For clearances refer page 10 2 The centre line of the flue is 115mm to rear of appliance including rear spacers 3 Carry out installation as per figure 26 ceiling plate installatio...

Страница 17: ...17 27...

Страница 18: ...tion instructions 2 The blue module ignition device needs to be removed to allow re moval of the gas control Remove LH screw from front lower section of ignition device Remove screw from front of rect...

Страница 19: ...rgise dependant on room temperature The burner should now operate on high setting To replace the fan pressure switch 1 Remove the lower pedestal front by unscrewing four M3 screws Refer page 11 figure...

Страница 20: ...e to this appliance For service to this appliance or spare parts contact the CANNON distributor Sampford IXL 52 70 Sparks Avenue Fairfield Vic 3078 Phone 1300 727 421 Fax 1300 727 425 email service sa...

Страница 21: ...way switch connector will be energised as soon as the flame has been sensed 5 Confirm spark is produced A blue spark can be seen when the heater ignition when heater is turned on process starts Ensure...

Страница 22: ...than 1 5 micro amps at all times Take precaution because the ionisation probe can have a high negative voltage and can cause shock 11 Fuse blowing If the fuse continues to blow check the solenoid coi...

Страница 23: ...23...

Страница 24: ...INS S F F F Part No F2904 Revision D 2009 Cannon FITZROY FREESTANDING...

Отзывы: