SERVICE INSTRUCTIONS (DO NOT MODIFY THIS APPLIANCE)

Cannon Power Flue | 17

General

1. Service work MUST be carried out by authorised 

personnel only.

2. Unplug from wall socket or turn off power at 

isolation switch if heater is hard wired.

3. Always shut off the gas supply and ensure that the 

heater is cool before commencing any service 
operations.

4. Always check for gas soundness after servicing.

To Replace Power Cord

Contact Sampford IXL service department.

To Replace The Gas Valve

1. Remove the fascia. Refer to page 14 of the 

installation instructions.

2. Unplug the cable from the gas control and 

disconnect the earth connection.

3. Disconnect the gas inlet (½” compression nut)

connection at entry gas control and the 16mm nut 
at the outlet of the gas control.

4. Remove the three screws from the cradle retaining 

the gas control.

5. Remove gas control valve from heater.
6. Replace gas control and check for gas tightness.

Note: Check the gas pressure on Boost and Low 
settings. Refer “gas control”, page 16.

To Replace The Ignition Module

1. Remove the fascia. Refer to page 14 of the 

installation manual.

2. Unplug wire connectors from ignition module.
3. Lift ignition module from base panel.

Note: Hook and loop mounting tape is used to secure 
ignition box.

4. Replace ignition module and ensure that all wires 

are reconnected correctly.

5. Check and re-set gas pressures.

To Replace The Electronic Controller

1. Remove the fascia. Refer to page 14 of the 

installation manual.

2. Disconnect the plugs on electronic controller.

FIG 33

3. Lift electronic controller from base panel.

Note: Hook and loop mounting tape is used to secure 
electronic controller.

4. Replace the electronic controller.
5. Check and re-set gas pressures.

To Replace The Inner Glass

Refer to page 14 of the installation instructions.
Fit the new glass.

Note: Ensure the inside surface of the glass is clean and 
free from finger marks.

To Replace The Burner And Spark/Sense Electrodes

1. Remove the logs from the burner chamber. Refer to 

page 15.

2. Remove the burner chamber front panel, 7 screws.
3. Disconnect the 16mm nut at the inlet of the injector.
4. Disconnect the spark and sense electrodes from the 

ignition module.

5. Remove the 2 M5 wing nuts from under the burner. 

Lift the burner assembly upwards and carefully 
remove from the burner chamber. Refer to 

FIG 34

.

6. Replace in reverse order, checking correct location 

of spark/sense electrodes. Refer 

FIG 35

. Spark gap 

between electrode and spark plate is 6 - 8 mm. 
Flame sense electrode MUST be in constant flame. 
Check for gas tightness. For log placement, refer to 
page 15 of this manual.

FIG 35

FIG 34

 

Securing the burner bed

FLAME
SENSE
ELECTRODE

SPARK
ELECTRODE

SPARK
PLATE

Содержание Canterbury CANTIB-PDEE series

Страница 1: ...utor Please leave instruction manual with the owner This appliance is designed manufactured and distributed by Tel 1300 727 421 Models FITZIB PDEXx Models CANTIB PDEEx Fitzroy Canterbury x Colour Shar...

Страница 2: ...ECIFICATIONS 8 CANTERBURY INBUILT POWER FLUE SPECIFICATIONS 9 REGULATORY LOCATOR 10 POWER FLUE INSTALLATION INSTRUCTIONS 11 14 FASCIA REMOVAL AND ELECTRICAL CONNECTION 15 LOG INSTALLATION GAS CONNECTI...

Страница 3: ...in accordance with the manufacturer s instructions d will not cover faults due to normal wear and tear with reasonable use nor consumable components such as globes filters glass items etc e will not c...

Страница 4: ...ng order Privacy The privacy of your personal information has always been important to us To learn more about how we collect keep and use your personal information please obtain a copy of our privacy...

Страница 5: ...take care to avoid burns or clothing ignition This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowle...

Страница 6: ...AL turn the heater on again if there have been several attempts to ignite the heater without success If there is an interruption to the power supply the heater will fail safely and switch off When the...

Страница 7: ...mation Console kit 4 sided surround kit Canterbury mesh kit Remote thermostat Spacer kit Extended flue kit Weatherproof kit Fitzroy mesh kit CONSOLE KIT REFER TO THE INSTRUCTIONS PROVIDED WITH THE CON...

Страница 8: ...regulator Integral part of controller Min inlet pressure 1 13 kPa NG 2 75 kPa Propane Fan 3 speed Ignition Electronic direct spark Power requirement 240V AC 10 Amp switch socket Power consumption 90 V...

Страница 9: ...r Integral part of controller Min inlet pressure 1 13 kPa NG 2 75 kPa Propane Fan 3 speed Ignition Electronic direct spark Power requirement 240V AC 10 Amp switch socket Power consumption 90 VA maximu...

Страница 10: ...FLUE HEATER IS FAN ASSISTED SEE COLUMN HIGHLIGHTED a Below eaves balconies and other projections Appliances up to 50 MJ hr input 300 200 Appliances over 50 MJ hr input 500 300 b From the ground above...

Страница 11: ...r or out through the terminal when installed horizontally The exhaust gas flue pipe must not trap and collect condensation This will adversely affect the performance of the heater POWER FLUE INSTALLAT...

Страница 12: ...m lengths Place a liberal amount of silicon sealant to the inside of the flexible flue pipe which is to be mounted onto the flue exhaust outlet Slip the flexible aluminium hose over the flue exhaust...

Страница 13: ...to seal the join and a hose clamp 3 Fit the PVC tubing and the air inlet to the other flexible tube using a hose clamp 4 Place terminal cover plate over both air intake and exhaust air pipes 5 Fit th...

Страница 14: ...ving Canterbury Fascia To fully remove the fascia unclip the switch cable from the cable connector on the PCB and unclip the cable from the clipping points on the rear of the fascia Electrical Connect...

Страница 15: ...d side of the heater at the bottom Refer FIG 26 2 With heater in position flanges should be hard against masonry Secure case flanges to the masonry Screw or bolt the flange through the slots provided...

Страница 16: ...8 9 Turn clockwise to increase pressure and anti clockwise to decrease pressure Refer FIG 32 5 Remove spanner and screwdriver Switch from BOOST to LOW to ensure settings are correct 6 Switch heater of...

Страница 17: ...m base panel Note Hook and loop mounting tape is used to secure ignition box 4 Replace ignition module and ensure that all wires are reconnected correctly 5 Check and re set gas pressures To Replace T...

Страница 18: ...Replace The Room Circulation Fan 1 Remove the fascia Refer to page 14 of the installation instructions 2 Remove the electronic controller and ignition module Refer to page 17 3 Disconnect the fan plug...

Страница 19: ...he fan is parallel to the top panel shown in FIG 38b Then remove the combustion fan making sure that it does not hit the male thread used to secure room circulation fan 9 Disconnect the electrical wir...

Страница 20: ...hin the allowed time Check the gas supply to the unit is not switched off Check the gas pressures Check the flame and spark electrode connections and that they are positioned correctly Ensure that the...

Страница 21: ...ng by starting the heater and either listening for the fan or check to see if air is blowing out of the flue pipe Check that the pressure tubes are connected correctly and not pinched or kinked The bl...

Страница 22: ...when this occurs check the solenoid coils for continuity Check that the gas pressure is present at the test point when the spark is being generated Check that there is gas to the inlet of the gas cont...

Страница 23: ...Cannon Power Flue 23 NOTES...

Страница 24: ...Certificate No Installed By COPY RATING LABEL HERE Don t Risk Your Appliance Warranty Only a licensed person will give you a compliance certificate showing that the work complies with all the relevan...