ELECTRICAL CONNECTION
"The installation must conform to the standard directives".
The manufacturer declines all responsibility for any damage that
may be caused by unsuitable or unreasonable use.
Warning :
l
l
V
ays chec
J
before any electrical operation
the supply tension
shown on the electricity meter, the adjustment of the circuit-
breaker, the continuity of the connection to earth to the installation
and that the fuse is suitable.
l
The electrical connection to the installation should be made via
a socket with a plug with earth, or via an omni pole cut-out
switch .
If the appliance has a socket outlet, it must be installed so that
the socket outlet is accessible.
The manufacturer cannot be held responsible for any accidents
resulting from the use of an appliance which is not connected
to earth, or with a faulty earth connection continuity.
l
ny
P
ueries regarding the power supply cord should be referred
to After Sales Service or a qualified technician.
Warning! This appliance must be earthed. In the absence of
adequate earthing you will notice that when touching the
metal parts of your appliance an electrical dispersion can be
felt due to the presence of a radio interference suppressor.
75,2
A power cord is supplied with the Trio which allows it to be
FRQQHFWHG RQO\ WR D SRZHU VXSSO\ RI 9 EHWZHHQ
SKDVHV RU EHWZHHQSKDVH DQGQHXWUDO&RQQHFW WRD
Amp socket.
75,2
A power cord is not supplied with this Trio, but it is equipped with
a terminal block that enables you to choose the correct connection
for the particular power supply.
The terminal block is located at the back of the Trio.
To open the terminal block :
. Locate the two tabs on the sides,
. place the screwdriver blade on the front of the tab, insert it (1)
and press down (2)
. Lift the cover off.
Terminal block
x 3 bars shunts
To connect :
. unscrew the cable grip,
. pass the cable through the cable grip,
. strip the insulation off the end of the each wire and connect them
to the according to the numbers shown in the table as well as
the "bars shunts".
INSTALLATION
Example of connection in monophase
3XWLQWKH
bars shunts
3XWLQ
the wires
3DVVWKHFDEOH
through the cable grip
Caution: incorrect tightening can cause dangerous heating
risks for the power supply cable.
H05VV-F
3 G 2,5 mm
2
Monophase
9
~
CABLE
TYPE-AERA
2 Phase
Shunt
Shunt
Neutral
Shunt
T Earth
CONNEC-
TION TO
THE
TERMINAL
BLOCK
To Shunt:
make a
bridge with
a shunt bar
H05RR-F,
H05VV-F or,
4 G 2,5 mm
2
H05VV-F or,
H05RR-F
5 G 1,5 mm
2
Three phases
22
9
~
Three phases
91
~
3KDVH
Shunt
3KDVH
Shunt
3KDVH
T Earth
3KDVH
2 Phase
3KDVH
Neutral
Shunt
T Earth
L2
L3
When the connection operation to the appliance terminals is
finished, tighten the cable clamp and close the cover.
08 GB