INSTALLATION
Installing a domestic appliance can be a complicated operation which if not carried out correctly, can seriously affect consumer
safety.
It is for this reason that a professionally qualified person should undertake the task who will carry it out in accordance with
the technical regulations in force.
In the event that this advice is ignored and the installation is carried out by an unqualified person, the manufacturer declines
all responsibility for any technical failure of the product whether or not it results in damage to goods or injury to individuals.
In case of installation of the cooker on a base, measures have to be taken to prevent the appliance slipping from the base
itself
*$6&211(&7,21
This must be done in compliance with the regulations in force in the installation country. In all cases, on the gas feed pipe provide a
stopcock, a regulator or regulator release device for propane gas. Only use valves, regulators ends and flexible tubes, regulators with
the official mark of the installation country.
Gas connection according to installation :
Natural Rigid, Flexible hose with mechanical fittings (1) - Soft rubber tube (2)
Butane Rigid, Flexible hose with mechanical fittings (1) - Soft rubber tube (2)
Propane Rigid, Flexible hose with mechanical fittings (1) - Soft rubber tube (2)
1 - provided the flexible hose can be inspected for its entire length.
2 - provided the soft rubber tube can be inspected for its entire length, its length does not exceed 1.5 metres and it is fitted with suitable
clamps at the ends.
1, 2 - soft tubes and flexible hoses with mechancial fittings must be arrange to be away from any flames, and not deteriorated by the
combustion gases, hot cooker parts or by any spills of hot food.
The flexible tube shall be fitted in such a way that does not pass through any space where it may become crushed/ kinked or damaged
in any way.
7+5((&211(&7,21237,216
•
RIGID PIPE CONNECTION
Connect directly to the manifold fittings.
•
CONNECTION BY FLEXIBLE HOSE WITH MECHANICAL FITTINGS
We recommend this type of connection.
Screw the hose nuts directly onto the manifold fitting on the one hand and onto the stop cock of the piping on the other hand.
•
CONNECTION BY SOFT RUBBER
We do not recommend this type of connection.
To be reserved solely for old installations not enabling any other option.
Screw the compliant end piece (2)
Fit the soft tube to the end piece on
the one hand and to the regulator or
to the valve outlet on the other hand.
(2) In all cases, make sure the seal is fitted. Following the connection operations, test the leak tightness using soapy water, testing by
flame is strictly prohibited.
Warning: If gas can be smelt in the vicinity of this appliance turn off the gas supply to the appliance and call the engineer directly. Do
not search for a leak with a naked flame.
GAS MODEL
%HIRUHLQVWDOOLQJWKHDSSOLDQFHWKHWHFKQLFLDQPXVW
- Check the compatibility between the Trio and the gas installation.
The Trio is factory set for use with the gas type as stated on the packaging and repeated on the rating plate
affixed to the cooker.
Natural gas G 20-20 mbar / G 25-25 mbar : main gas
- If necessary, change the gas.
To adapt the gas burners cooker fit suitable jets that provide the nominal flow rate (as explained on
paragraph changing the gas type).
• For installation the technician must :
The Trio is Class2 - Sub class 1 ; furniture adjacent to the unit must not be higher than the top of the
appliance.
- If the Trio is fitted next to a cabinet on either side, the distance between the Trio and the cabinet must be at
least 15 cm (see Figure 1); while the distance between the Trio and the rear wall must be at least 5,5 cm.
The distance between the Trio and any other unit or appliance above it (e.g. An extractor hood) must be no
less than 70 cm (Figure 1).
- The cooker has adjustable feet for perfect levelling on the floor.
- Make the gas connection to the installation according to the gas supply.
- Connect the cooker electrically in compliance with the information given on paragraph electrcal connection.
- If the gas type has been changed, adjust the minimum flow of each gas burner (as explained on paragraph changing the gas type).
- Connect the Trio to the water supply and the water drainage (see paragraph water connection).
06 GB
ANY MODIFICATION MADE TO THE GAS SETTING SHOULD BE NOTED ON THE RATING PLATE AFFIXED TO THE COOKER.
Figure 1