TABLE FOR THE CHOICE OF THE INJECTORS
Cat: I 3+
G30/G31
28-30/37 mbar
BURNERS
Nominal
Power [kW]
Reduced
Power [kW]
Ø injector
[1/100 mm]
Auxiliary (A)
1,00
0,40
50
Semi-rapid (SR)
1,75
0,45
66
Rapid (R)
3,00
0,75
87
Fish (F)
2,65
1,50
81
Triple-ring (TR)
3,50
1,50
93
Dual (DB) - inner crown
0,80 (*)
0,40 (*)
46
Dual (DB) - outer crown
3,40 (**)
1,50 (**)
65 (x2)
GAS MAINTENANCE
LUBRICATION OF THE GAS TAPS
In case of difficulty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation, maintenance and conversion of the appliance
must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
Some models - for the gas category check the data label attached on the appliance
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Auxiliary (A)
2,00
Semi-rapid (SR)
3,50
Rapid (R)
6,00
Fish (F)
5,30
Triple-ring (TR)
7,00
Dual (DB) - inner crown only
1,60
Dual (DB) - outer crown
6,80
Dual (DB) - inner & outer crown
8,40
(*) Power calculated with inner crown operating.
(**) Power calculated with inner and outer crowns operating.
Содержание CHW938X ALG
Страница 7: ...7 7 ADVICE ADVICE for the for the INSTALLER INSTALLER...
Страница 21: ...21 21 ADVICE ADVICE for the for the USERS USERS...
Страница 31: ...31 31 CORRECT WRONG Fig 2 8b Fig 2 8a...
Страница 36: ...36 36 S F C T Fig 3 1 Fig 3 2 S T MODELS WITH TRIPLE RING BURNER Fig 3 3 Some models only Some models only...
Страница 37: ...37 37 A B Fig 3 5 Fig 3 6 T T S S Fig 3 4 MODELS WITH DUAL BURNER Some models only...
Страница 39: ...39 39...