These instructions are suitable for the following boilers :

Britony System II Plus   80
Britony System II Plus 100

Do not forget the Logbook!

Chaffoteaux & Maury supports Benchmark, the heating industry code to ensure the correct installation, commissioning and
servicing of domestic central heating systems.

To The Householder

Make sure you have a completed Log Book for your boiler. This is the record of the commissioning of the boiler to the
manufacturer’s instructions. It contains important information about your particular installation that may be required by
service engineers. The Log Book will also provide contact details for the installer should you need guidance in the use of this
appliance or if there are any problems.

As with your car, your boiler will work more reliably and efficiently if regularly serviced. We recommend an annual service
check. The service history of the appliance will be marked on the Log Book.

In the unlikely event of any problems with your boiler or system you should first contact your installer. If there is a fault with
the boiler during its warranty period which your installer is unable to rectify they will contact our service department.

A charge may be made if Chaffoteaux & Maury Service is called out to resolve a non-product related fault.

Your statutory rights are not affected.

TO CONTACT C&M SERVICE, PLEASE CALL THE NATIONAL WARRANTY HELPLINE ON:

0870 600 9888

To The Installer

As part of the commissioning of this appliance it is vital that the Log Book is completed and given to the Householder.
Please ensure that your customer is aware of the importance of keeping the Log Book safe as a record of the installation
and the appliance service history.

Please ensure that your customer is aware of the correct operation of the system, boiler and controls.

CUSTOMER CARE
Chaffoteaux & Maury, as a leading brand of domestic and commercial water heating appliances is committed to providing
high quality products and a high quality after sales service. If it is necessary to contact an engineer, then telephone the
national warranty helpline 0870 600 9888.
Advice on installation or servicing can also be obtained by contacting the Chaffoteaux Technical Department.

Tel: 0870 241 8180
Fax: 01494 459775

GUARANTEE
The manufacturer`s guarantee is for 12 months from the date of purchase. The guarantee is invalidated if the appliance is
not installed in accordance with the recommendations made herein or in a manner not approved by the manufacturer. To
assist us in providing you with an efficient after sales service, please return the guarantee registration card enclosed with the
boiler without delay.

STATUTORY REQUIREMENTS
The installation of this appliance must be carried out by a CORGI Registered person or other competent person and in
accordance with the requirements of the Gas Safety (Installation and Use) Regulations. 
In addition, the installation must also comply with the current byelaws of Local Water Undertakings, Building Regulations,
IEE Wiring Regulations, Local Authority Building Standards (Scotland) Regulations and the Safety Document 635 The
Electricity at work Regulation. The appliance named below does not contain any asbestos or asbestos products, or mercury
derivatives. Additional CFC’s have not been used in this product.
The appliance does not contain any potential hazard in relation to the COSHH regulations.
It should also be carried out in accordance with current editions of the following British Standards Codes of practice: BS
6891, BS 5440 parts 1 and 2, BS 5449 part 1, BS 7593, BS 6798, BS 5546, BS 4814, BS 7074 part 1 and 2, BS 7671 and
Institute of Gas Engineers document IGE/UP/7.
If there is a possibility of the incoming mains water pressure exceeding 10 bar then a suitable pressure limiting valve must
be fitted where pressures exced 6 bars a pressure limiting is preferred.
Precautions: During servicing, keep the dust generation to a minimum and avoid inhaling any dust and contact with the skin
and eyes. Normal handling and use will not present any discomfort, although some people with a history of skin complaints
may be susceptible to irritation. When disposing of the ceramic lining, ensure that it is securely wrapped and wash hands
after contact.

            

Содержание Britony System II Plus 80 Nat

Страница 1: ...nder Fanned Flue system Installation and Operating instructions These instructions Must Be Left With The Appliance Manufactures N Model Type Gas Council N 200907815037 31 Britony System II Plus 80 Nat...

Страница 2: ...to contact an engineer then telephone the national warranty helpline 0870 600 9888 Advice on installation or servicing can also be obtained by contacting the Chaffoteaux Technical Department Tel 0870...

Страница 3: ...ic ignition and is suitable for use with all modern electrical control systems The boiler is designed for sealed systems only and a circulating pump expansion vessel together with a pressure gauge and...

Страница 4: ...2 Overheat sensor 13 Flue hood with fan 14 Central heating control thermistor 15 Three position Selector switch Pilot O Hot water only Hot water Central heating 16 Primary circuit control thermistor 1...

Страница 5: ...t3 h 37 44 8 Inlet pressure Nominal in mbar 37 37 Nominal in in wg 14 8 14 8 Burner pressure Nominal in mbar 35 30 4 Nominal in in wg 14 12 2 BUTANE L P G G30 Gas rate Maximum in kg h 2 04 2 45 Maximu...

Страница 6: ...quired 450 Height 850 Depth 380 All dimensions in mm Safety valve center line Minimum clearances Both sides 5 mm Above casing 170 mm Below casing 200 mm Front for servicing 500 mm Front in operation 5...

Страница 7: ...o supply central heating the selector switch 15 fig 6 must be in position This will be confirmed by the green indicator light 18 fig 6 When there is a demand for heating either from the room thermosta...

Страница 8: ...d does not require specific ventilation If it is installed in a cupboard or compartment permanent ventilation is not required for cooling purposes Gas Supply The gas installation and soundness testing...

Страница 9: ...sing washers provided in the plastic bag 3 x fibre washers for the water pipes 1 x washer mesh filter F CH return connection 1 x rubber washer R for gas connection Provision must be maid to reduce as...

Страница 10: ...ire If using a room thermostat or other external control they can be connected in place of the link on the multipin plug C fig 15 Note Use only controls designed for voltage free switching or 24V supp...

Страница 11: ...timed A simple time clock can be used such as the Danfoss Randall 103 P 1 2 Cylinder Thermostat N L P 1 Thermal Cut Out Main Boiler Connector Interface PCB N L 1 2 3 N PH 1 3 2 N PH LINK 4 5 6 H W C H...

Страница 12: ...switch 15 fig 17 to heating and hot water position Turn the boiler thermostat to maximum 16 fig 17 The boiler will light Allow the boiler to heat system Check the inlet gas pressure working pressure...

Страница 13: ...ler is fitted with a pre adjusted by pass Although adjustment is not normally necessary the by pass can be reset by turning screw D Fig 18 anticlockwise to open the by pass using the chart below for g...

Страница 14: ...heat the orange burner on indicator will light and the heating will be on When the heating is on it will be interrupted while the cylinder is reheated The boiler will switch back automatically to hea...

Страница 15: ...15 Notes...

Страница 16: ...in this document Manufacturer Chaffoteaux Maury France Commercial subsidiary MTS GB Limited MTS Building Hughenden Avenue High Wycombe Bucks HP13 5FT Telephone 01494 755600 Fax 01494 459775 Internet...

Отзывы: