10

Control panel (fig. 21)

15. - Three position Selector switch

Pilot

O

Hot water only                      

Hot water + Central heating

16. - 

Heating flow temperature adjustment

18. -  

Green indicator - Power ON

19. -  

Orange indicator - Burner ON

20. -  

Red indicator - Lock out / flame failure

21. - “RESET” button

22. -  

Pressure gauge

Switching on

1) Check that the gas service tap is opened at the gasmeter

and main power is on.

2) Check that pressure in central heating system is above

0.7 bar and below 2.5 bar with the pressure gauge 

22.

3) Open the gas tap 

31 by turning from right to left.

4) The boiler is now ready to use.

Hot Water

1) Turn selector switch 

15 to position 

The green

"power on" indicator 

will light.

2) The orange "burner on" indicator 

will light and

the cylinderwill be heated.

Heating and Hot Water

1) Turn selector switch 

15 to position 

. The green

"power on" indicator 

will light.

2) If the room thermostat (if fitted), the boiler temperature

control 

and the clock (if fitted) are all calling for heat,

the orange "burner on" indicator 

will light and the

heating will be on.

When the heating is on, it will be interrupted while the

cylinder is reheated. The boiler will switch back

automatically to heating when the cylinder is hot. This is

normal.

Note: If the boiler has been turned off for some time the

first attempt to light it may result in a lockout 

. If this

happens press the reset button 

21 and the boiler will light.

To Turn Boiler Off Completely

1) Turn the selector switch 

15 to the off position  

O

2) Turn the gas tap 

31 from left to right "STOP".

The outer control panels of the unit’s case must only be

cleaned with a damp cloth. Do not use abrasive cleaners.

The control panel can be wiped with either a damp or dry

cloth.  Spray polishes mst not be used on the control panel

surface or knobs.  Care must be taken in preventing any

liquid entering the appliance.

N

OTE

: This appliance must be earthed.

Isolating Taps (fig. 22)

taps shown in Open position

30. CH Flow isolating valve

31. Gas service tap

32. H.W. flow

33. CH Return isolating valve

34. Pressure relief valve

C

15

16

18

20

21

19

22

bar

0

1

3

4

30

31

32

33

34

Fig. 22

Fig. 21

User’s Instructions

                                 

Содержание Britony System II Plus 80 Nat

Страница 1: ...nder Fanned Flue system Installation and Operating instructions These instructions Must Be Left With The Appliance Manufactures N Model Type Gas Council N 200907815037 31 Britony System II Plus 80 Nat...

Страница 2: ...to contact an engineer then telephone the national warranty helpline 0870 600 9888 Advice on installation or servicing can also be obtained by contacting the Chaffoteaux Technical Department Tel 0870...

Страница 3: ...ic ignition and is suitable for use with all modern electrical control systems The boiler is designed for sealed systems only and a circulating pump expansion vessel together with a pressure gauge and...

Страница 4: ...2 Overheat sensor 13 Flue hood with fan 14 Central heating control thermistor 15 Three position Selector switch Pilot O Hot water only Hot water Central heating 16 Primary circuit control thermistor 1...

Страница 5: ...t3 h 37 44 8 Inlet pressure Nominal in mbar 37 37 Nominal in in wg 14 8 14 8 Burner pressure Nominal in mbar 35 30 4 Nominal in in wg 14 12 2 BUTANE L P G G30 Gas rate Maximum in kg h 2 04 2 45 Maximu...

Страница 6: ...quired 450 Height 850 Depth 380 All dimensions in mm Safety valve center line Minimum clearances Both sides 5 mm Above casing 170 mm Below casing 200 mm Front for servicing 500 mm Front in operation 5...

Страница 7: ...o supply central heating the selector switch 15 fig 6 must be in position This will be confirmed by the green indicator light 18 fig 6 When there is a demand for heating either from the room thermosta...

Страница 8: ...d does not require specific ventilation If it is installed in a cupboard or compartment permanent ventilation is not required for cooling purposes Gas Supply The gas installation and soundness testing...

Страница 9: ...sing washers provided in the plastic bag 3 x fibre washers for the water pipes 1 x washer mesh filter F CH return connection 1 x rubber washer R for gas connection Provision must be maid to reduce as...

Страница 10: ...ire If using a room thermostat or other external control they can be connected in place of the link on the multipin plug C fig 15 Note Use only controls designed for voltage free switching or 24V supp...

Страница 11: ...timed A simple time clock can be used such as the Danfoss Randall 103 P 1 2 Cylinder Thermostat N L P 1 Thermal Cut Out Main Boiler Connector Interface PCB N L 1 2 3 N PH 1 3 2 N PH LINK 4 5 6 H W C H...

Страница 12: ...switch 15 fig 17 to heating and hot water position Turn the boiler thermostat to maximum 16 fig 17 The boiler will light Allow the boiler to heat system Check the inlet gas pressure working pressure...

Страница 13: ...ler is fitted with a pre adjusted by pass Although adjustment is not normally necessary the by pass can be reset by turning screw D Fig 18 anticlockwise to open the by pass using the chart below for g...

Страница 14: ...heat the orange burner on indicator will light and the heating will be on When the heating is on it will be interrupted while the cylinder is reheated The boiler will switch back automatically to hea...

Страница 15: ...15 Notes...

Страница 16: ...in this document Manufacturer Chaffoteaux Maury France Commercial subsidiary MTS GB Limited MTS Building Hughenden Avenue High Wycombe Bucks HP13 5FT Telephone 01494 755600 Fax 01494 459775 Internet...

Отзывы: