Making the Electrical Connections
Hinge down the electrical box to gain access to the
electrical connections. Push in the tabs (
P fig. 14) on either
side of the boiler and pivot the box forward.
Undo the two retaining screws, remove cover and remove
cable clamp. (
A fig. 14)
Connect the live and neutral wires to the multipin plug
D
(fig 15) of the PCB
E leaving sufficient earth wire to
connect to the earthing point. (
B fig 16)
Note: The connections should be made so that should the
lead be pulled from its anchorage, the current carrying
wires become taut before the earth wire.
If using a room thermostat or other external control, they
can be connected in place of the link on the multipin plug
C (fig 15).
Note: Use only controls designed for voltage free
switching or 24V supply.
Connect multipin plug
C onto into the socket on the power
board. Connect multipin plug
D to the interface PCB inside
the cover (see fig. 15).
Secure the cables using the cable clamp and replace the
cover. To prevent damage, the cables should then be
routed through the cable support on the right hand side of
the chassis.
P
A
P
cable clamp
Fig. 15
Socket for
connector
C
Fig. 16
Earth pillar
B
N
230V
PH
THERMOSTAT
R. ACC
1
32
S
SECTEUR
AQUASTAT
BALLON
PH
PH
N
N
D
E
connector
electronic board
C
connector
C
Mains
Cylinder
thermostat
Fig. 14