background image

 

 

1.2.3

 

Mechanical 

 
The  mechanical  dimensions  of  the  module  are  in  conformance  with  ANSI/VITA  12-1996  for 
single-wide M-Module modules.  The nominal dimensions are 5.687” (144.5 mm) long 

 2.082” 

(52.9 mm) wide.    
 
1.2.4

 

Bus Compliance 

 
The  module  complies  with  the  ANSI/VITA  12-1996  Specification  for  single-wide  M-Modules 
and the MA-Module trigger signal extension.  The module also supports the optional IDENT and 
VXI-IDENT functions.  
 
 

Module Type: 

M-Module 

 

Addressing: 

A08 

 

Data: 

D16 

 

Interrupts: 

supported 

 

DMA: 

not supported 

 

Triggers: 

not supported 

 

Identification: 

IDENT 

 

 

 

Manufacturer ID: 

0FFF

16   

(See note below) 

 

Model Number: 

068A

16

  

 

VXI Model Number:  025F

16 

 

Note:  C&H obtained the manufacturing rights from Hewlett Packard (Agilent) for this module.  The 

ID’s have been retained as Hewlett Packard to provide compatibility with existing SW drivers. 

 

1.2.5

 

Applicable Documents 

 
ANSI/VITA 12-1996  Standard  for  The  Mezzanine Concept M-Module Specification, Approved 
May  20,  1997,  American  National  Standards  Institute  and  VMEbus  International  Trade 
Association, 7825 E. Gelding Dr. Suite 104, Scottsdale, AZ 85260-3415, 

http://www.vita.com

 

C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com

Содержание M222

Страница 1: ...O R M E R L Y H P E 2 2 7 4 A U S E R S M A N U A L 4 C H A N N E L F O R M C P O W E R R E L A Y M M O D U L E Document Part No 11029574 C H Technologies Inc 445 Round Rock West Drive Round Rock TX 7...

Страница 2: ...t Hewlett Packard Agilent User Manual s with their expressed written permission The information and or drawings set forth in this document and all rights in and to inventions disclosed herein which mi...

Страница 3: ...amendments to the manual If any amendments are provided for this manual they are printed on colored paper and will be provided with the module and manual Manual updates may also be found on out web s...

Страница 4: ...are available in many formats such as Ethernet VME VXI PXI cPCI and the PC Contained within this manual are the physical and electrical specifications installation and startup procedures functional de...

Страница 5: ...PECTION 5 2 2 HANDLING PRECAUTIONS 5 2 3 INSTALLATION OF M MA MODULES 5 2 4 PREPARATION FOR RESHIPMENT 6 3 0 FUNCTIONAL DESCRIPTION 7 3 1 OVERVIEW 7 3 1 1 M Module Interface 7 3 1 2 ID EEPROM 7 3 2 ID...

Страница 6: ...isters 9 Figure 4 Effects of Opening Closing Relay 11 Figure A 1 Front Panel I O Signals A 1 LIST OF TABLES Table I Specifications 2 Table II I O Address Map Command Summary 8 Table III M MA Module PR...

Страница 7: ...her system architectures 1 1 PURPOSE OF EQUIPMENT The M222 can connect multiple instruments to multiple points in your test system This provides flexible interconnection between test points instrument...

Страница 8: ...on Clean room Environment any terminal to any other terminal 60 43 68 VDC VAC rms VAC peak Current non inductive Per Switch DC Per Switch AC Per Switch AC 5 3 53 5 A A rms A peak Power Per Switch DC P...

Страница 9: ...MA not supported Triggers not supported Identification IDENT Manufacturer ID 0FFF16 See note below Model Number 068A16 VXI Model Number 025F16 Note C H obtained the manufacturing rights from Hewlett P...

Страница 10: ...4 C H Technologies Inc 445 Round Rock West Drive Round Rock TX 78681 www chtech com...

Страница 11: ...a static controlled workstation whenever possible At a minimum avoid work areas that are potential static sources such as carpeted areas Avoid unnecessary contact with the components on the module 2 3...

Страница 12: ...ealing the bag keep trapped air volume to a minimum The shipping container should be a rigid box of sufficient size and strength to protect the equipment from damage If the module was received separat...

Страница 13: ...ows communication between the M222 and the carrier module The interface is an asynchronous 16 bit data bus with interrupt capabilities The interface adheres to the ANSI VITA 12 1996 Standard for The M...

Страница 14: ...the registers is shown in Table II Details of the registers are provided in Figure 3 Table II I O Address Map Command Summary Offset hex Register Name Register Type 00 Status Register Read Only 02 Con...

Страница 15: ...ing this register clears a pending interrupt Reg 14 Relay Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Write Not Used CH3 CH2 CH1 CH0 Read Not Used CH3 CH2 CH1 CH0 CH0 CH3 Channel 1 channel open COM NC 0...

Страница 16: ...Revision Number 1 0002 3 Module Characteristics 2 1868 4 7 Reserved 0000 8 15 M Module Specific 0000 16 VXI Sync Code ACBA 17 VXI ID 0FFF 3 18 VXI Device Type 3 F25F 19 31 Reserved 0000 32 63 M Module...

Страница 17: ...CLOSE Each relay channel can be separately controlled with the Relay Register Reg 0x14 Writing a 1 to a bit will OPEN the relay i e connect the common terminal to the normally closed terminal and writ...

Страница 18: ...12 C H Technologies Inc 445 Round Rock West Drive Round Rock TX 78681 www chtech com...

Страница 19: ...ctive that may be applied to the M222 is Per Switch 5 ADC 5 AAC peak 100W DC 100VA AC Per Module 300W DC 300VA AC Pin Use Pin Use Pin Use 1 CH0_NC 16 CH0_NC 31 CH0_NC 2 CH0_COM 17 CH0_COM 32 CH0_COM 3...

Страница 20: ...A 2 C H Technologies Inc 445 Round Rock West Drive Round Rock TX 78681 www chtech com...

Страница 21: ...N O T E S C H Technologies Inc 445 Round Rock West Drive Round Rock TX 78681 www chtech com...

Страница 22: ...C H Technologies Inc 445 Round Rock West Drive Round Rock TX 78681 www chtech com...

Страница 23: ...tsoever You may of course continue to use the information which you supply Please refrain from using this form for technical questions or for requests for additional publications this will only delay...

Страница 24: ...her or not your comments were being incorporated NOTE This form may not be used to request copies of documents or to request waivers deviations or clarification of specification requirements on curren...

Отзывы: