background image

 

 

10 

3.2.2

 

Module Identification 

 
The  M222  supports  the  identification  function  called  IDENT.    This  IDENT  function  provides 
information  about  the  module  and  is  stored  in  a  sixteen-word  deep  (32  byte)  serial  PROM.  
Access  is  accomplished  with  read/write  operations  on  the  last address in  IOSpace (hex FE) and 
the data is read one bit at a time.  The PROM is compatible with a standard IC 9603 type PROM.  
For specific timing information refer to the 9603 or compatible PROM data sheet.  Data should 
not be written to the PROM. 
 
The  module  also  supports  the  VXI-IDENT  function.    This  function  is  not  part  of  the  approved 
ANSI/VITA  12-1996  standard.    This  extension  to  the  M-module  IDENT  function increases the 
size  of  the  PROM  to  64  words  and  includes  VXI  compatible  ID  and  Device  Type  Registers.  
Details are shown in Table III. 
 

Table III.  M/MA Module PROM IDENT Words 

Word 

Description 

Value (hex) 

Sync Code 

5346 

Module Number 

068A 

Revision Number 

1

 

0002 

Module Characteristics 

2

 

1868 

4-7 

Reserved 

0000 

8-15 

M-Module Specific 

0000 

16 

VXI Sync Code 

ACBA 

17 

VXI ID 

0FFF 

3

 

18 

VXI Device Type 

3

 

F25F 

19-31 

Reserved 

0000 

32-63 

M-Module Specific 

0000 

 

Notes: 
 

1)  A Revision Number greater than 1 indicates that the module was manufactured by C&H Technologies. 

 

2)  The Module Characteristics bit definitions are: 

 

Bit(s) 

Description 

 

15 

0 = no burst access 

 

14/13 

unused 

 

12 

0 = needs 

12V 

 

11 

1 = needs +5V 

 

10 

0 = no trigger outputs 

 

0 = no trigger inputs 

 

8/7 

00 = no DMA requestor 

 

6/5 

11 = interrupt type 

 

4/3 

01 = 16-bit data 

 

2/1 

00 = 8-bit address 

 

0 = no memory access 

 

3)  The  VXI  ID  of  0xFFF  is  the  identification  value  for  Hewlett-Packard.    C&H  has  left  the  ID  equal  to 

this value to allow operation with existing E2274A software drivers.  The revision number (see note 1) 
can be used to identify the module as manufactured by C&H.  

 

4)  The VXI Device Type word contains the following information:  

 

Bit(s) 

Description 

 

15-12 

F

16

 = 256 bytes of required memory 

 

11-0 

25F

16

 = C&H specified VXI model code for M222 

 

C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com

Содержание M222

Страница 1: ...O R M E R L Y H P E 2 2 7 4 A U S E R S M A N U A L 4 C H A N N E L F O R M C P O W E R R E L A Y M M O D U L E Document Part No 11029574 C H Technologies Inc 445 Round Rock West Drive Round Rock TX 7...

Страница 2: ...t Hewlett Packard Agilent User Manual s with their expressed written permission The information and or drawings set forth in this document and all rights in and to inventions disclosed herein which mi...

Страница 3: ...amendments to the manual If any amendments are provided for this manual they are printed on colored paper and will be provided with the module and manual Manual updates may also be found on out web s...

Страница 4: ...are available in many formats such as Ethernet VME VXI PXI cPCI and the PC Contained within this manual are the physical and electrical specifications installation and startup procedures functional de...

Страница 5: ...PECTION 5 2 2 HANDLING PRECAUTIONS 5 2 3 INSTALLATION OF M MA MODULES 5 2 4 PREPARATION FOR RESHIPMENT 6 3 0 FUNCTIONAL DESCRIPTION 7 3 1 OVERVIEW 7 3 1 1 M Module Interface 7 3 1 2 ID EEPROM 7 3 2 ID...

Страница 6: ...isters 9 Figure 4 Effects of Opening Closing Relay 11 Figure A 1 Front Panel I O Signals A 1 LIST OF TABLES Table I Specifications 2 Table II I O Address Map Command Summary 8 Table III M MA Module PR...

Страница 7: ...her system architectures 1 1 PURPOSE OF EQUIPMENT The M222 can connect multiple instruments to multiple points in your test system This provides flexible interconnection between test points instrument...

Страница 8: ...on Clean room Environment any terminal to any other terminal 60 43 68 VDC VAC rms VAC peak Current non inductive Per Switch DC Per Switch AC Per Switch AC 5 3 53 5 A A rms A peak Power Per Switch DC P...

Страница 9: ...MA not supported Triggers not supported Identification IDENT Manufacturer ID 0FFF16 See note below Model Number 068A16 VXI Model Number 025F16 Note C H obtained the manufacturing rights from Hewlett P...

Страница 10: ...4 C H Technologies Inc 445 Round Rock West Drive Round Rock TX 78681 www chtech com...

Страница 11: ...a static controlled workstation whenever possible At a minimum avoid work areas that are potential static sources such as carpeted areas Avoid unnecessary contact with the components on the module 2 3...

Страница 12: ...ealing the bag keep trapped air volume to a minimum The shipping container should be a rigid box of sufficient size and strength to protect the equipment from damage If the module was received separat...

Страница 13: ...ows communication between the M222 and the carrier module The interface is an asynchronous 16 bit data bus with interrupt capabilities The interface adheres to the ANSI VITA 12 1996 Standard for The M...

Страница 14: ...the registers is shown in Table II Details of the registers are provided in Figure 3 Table II I O Address Map Command Summary Offset hex Register Name Register Type 00 Status Register Read Only 02 Con...

Страница 15: ...ing this register clears a pending interrupt Reg 14 Relay Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Write Not Used CH3 CH2 CH1 CH0 Read Not Used CH3 CH2 CH1 CH0 CH0 CH3 Channel 1 channel open COM NC 0...

Страница 16: ...Revision Number 1 0002 3 Module Characteristics 2 1868 4 7 Reserved 0000 8 15 M Module Specific 0000 16 VXI Sync Code ACBA 17 VXI ID 0FFF 3 18 VXI Device Type 3 F25F 19 31 Reserved 0000 32 63 M Module...

Страница 17: ...CLOSE Each relay channel can be separately controlled with the Relay Register Reg 0x14 Writing a 1 to a bit will OPEN the relay i e connect the common terminal to the normally closed terminal and writ...

Страница 18: ...12 C H Technologies Inc 445 Round Rock West Drive Round Rock TX 78681 www chtech com...

Страница 19: ...ctive that may be applied to the M222 is Per Switch 5 ADC 5 AAC peak 100W DC 100VA AC Per Module 300W DC 300VA AC Pin Use Pin Use Pin Use 1 CH0_NC 16 CH0_NC 31 CH0_NC 2 CH0_COM 17 CH0_COM 32 CH0_COM 3...

Страница 20: ...A 2 C H Technologies Inc 445 Round Rock West Drive Round Rock TX 78681 www chtech com...

Страница 21: ...N O T E S C H Technologies Inc 445 Round Rock West Drive Round Rock TX 78681 www chtech com...

Страница 22: ...C H Technologies Inc 445 Round Rock West Drive Round Rock TX 78681 www chtech com...

Страница 23: ...tsoever You may of course continue to use the information which you supply Please refrain from using this form for technical questions or for requests for additional publications this will only delay...

Страница 24: ...her or not your comments were being incorporated NOTE This form may not be used to request copies of documents or to request waivers deviations or clarification of specification requirements on curren...

Отзывы: