CHARACTERISTICS
Limit
Parameter
Conditions
Min
Typ.
Max
Units
Data Transfers
Throughput
Ethernet – block read
1, 3
Ethernet – block write
2, 3
400K
300K
450K
350K
bytes/sec
bytes/sec
AC Input Power (IEC 320-C13)
Level
AC
85
265
V
Power Consumption
for full M-Module support
100
W
DC Input Power (DIN Connector)
Level
DC
36
48
75
V
Power Consumption
for full M-Module support
100
W
Power Consumption
Carrier (internal logic)
-0001 with trigger support
-0002 without trigger support
25
22
W
W
Triggers (-0001 version only)
Maximum Frequency
40
MHz
Minimum Pulse Width
Driven Mode
≤
10 meter connection segment
≤
20 meter connection segment
Wired-OR Mode
≤
10 meter connection segment
≤
20 meter connection segment
10
20
20
40
ns
ns
ns
ns
Intermodule Trigger Delay
M-module to M-Module
21
27
ns
Intermodule Skew
M-module to M-Module
3
6
ns
TTL Trigger Delay
External BNC connector to M-Module
M-module to external BNC connector
22
24
28
30
ns
ns
LVDS Trigger Delay
External connector to M-Module
M-module to external connector
20
20
26
26
ns
ns
BNC Output Level
into a high impedance load
3.8
5.0
5.4
V
BNC Output Impedance
50
BNC Input Level
TLVL = 0
4
TLVL = 1
2.5
1.4
V
V
BNC Input Impedance
TIMP = 0
4
TIMP = 1
900K
1M
50
LVDS Differential Output
Magnitude
480
650
mV
LVDS Differential Input
(Type 1 receiver)
Threshold, positive-going
Threshold, negative-going
Hysteresis
-50
25
50
mV
mV
mV
Cooling
Temperature Rise
20
°C
Temperature Accuracy
-1
+1
°C
Notes:
1. Several milliseconds of overhead and latency occur on each command issued. The effect of this
overhead and latency is reduced by transferring large amounts of data with a single block read
command. Maximum read throughput is achieved by reading >4K bytes of data from a FIFO type
register on an M-Module using the Block Read command. Host software may vary and can limit the
maximum throughput.
2. The maximum number of bytes that can be written in a single block write command is 1024.
3. Ethernet is a non-deterministic communications interface. Realized throughput may be significantly
degraded by network activity or other factors that may affect network performance.
4. TLVL and TIMP refer to register bits in the
TTL
Trigger Control
register. Refer to section 4.6.5.
C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, Texas 78681 <> www.chtech.com
Содержание EM405-8
Страница 46: ...A 2 C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com ...
Страница 47: ...N O T E S C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com ...
Страница 48: ... C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com ...