34
Reg. 50
External Input TTL Trigger Control
Byte
51
50
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Write
ITENx
ITLVL
ITIMP
-
ITP
ITRF
ITEL
-
-
-
-
-
-
ITECN
Read
ITENx
ITLVL
ITIMP
0
ITP
ITRF
ITEL
0
0
0
0
0
0
ITECN
ITENx
Enabled (1 = enabled)
ITLVL
External Input Trigger Threshold Level (0 = +2.5V, 1 = +1.4V)
ITIMP
External Input Trigger Impedance (0 = high (>900K
), 1 = 50
)
ITP
Polarity (0 = normal, 1 = invert)
ITRF
Rising/Falling Edge (0 = rising, 1 = falling) (only used when Edge Triggering)
ITEL
Edge/Level Sensitive (0 = edge, 1 = level)
ITECN
EDGECLK Number (only used when Edge Triggering)
Reg. 52
External Output TTL Trigger Control
Byte
53
52
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Write
OTENx
-
-
-
OTP
-
-
-
-
OTST
-
OTSN
Read
OTENx
0
0
0
OTP
0
0
0
0
OTST
0
OTSN
OTENx
Enabled (1 = enabled)
OTP
Polarity (0 = normal, 1 = invert)
OTST
Signal Source Type
1
0 0 0
External TTL Trigger
0 0 1
External LVDS Trigger
0 1 0
M-Module Trigger A
0 1 1
M-Module Trigger B
1 0 0
reserved
1 0 1
reserved
1 1 0
reserved
1 1 1
reserved
OTSN
Signal Source Number
2
Notes:
1.
The specified source must be configured as an input for proper operation.
2.
The specific number of the signal source. Not used for External TTL Trigger signal sources.
Figure 11. EM405-8 Registers (continued)
C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, Texas 78681 <> www.chtech.com
Содержание EM405-8
Страница 46: ...A 2 C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com ...
Страница 47: ...N O T E S C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com ...
Страница 48: ... C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com ...