24
25
Meter Cable
Front Cover
1.
Disconnect the meter cable from the meter. (If flow
meter is attached)
2.
Remove the front cover of the valve.
3.
Remove the piston screw and washer from the piston
rod.
4.
Remove the two screws from the powerhead as shown
5.
Life the powerhead from the valve body assembly
6.
Replace the powerhead by reverse following the steps in this section
Piston Screw & Washer
Powerhead
Assembly
Valve Body
Assembly
2 X Screws from Powerhead
Before Servicing
1.
Turn off water supply to conditioner :
a.
If the conditioner installation has a 3 valve bypass system first open the valve in the bypass line, then close the valves at the conditioner inlet & outlet.
b. If the conditioner has an integral bypass valve, put it in the bypass position.
c. If there is only a shut-off valve near the conditioner inlet, close it.
2.
Relieve water pressure in the conditioner by stepping the control into the backwash position momentarily. Return the control to the In Service position.
3.
Unplug Electrical Cord from outlet.
4.
Disconnect drain line connection.
SERVICING 565 VALVE
WARNING!
ELECTRICAL SHOCK HAZARD! UNPLUG THE UNIT BEFORE
REMOVING THE COVER OR ACCESSING ANY INTERNAL CONTROL PARTS.
CAUTION!
Disassembly while under pressure can result in flooding. Always follow these steps
prior to servicing the valve.
TIMER REPLACEMENT