background image

20

1

1.

  Connect the transformer  

  to the valve.  Plug the  

  12-volt transformer into  

  a 120 VAC 60 Hz outlet.

STARTUP INSTRUCTIONS

MENU SET/REGEN

Program Valve

1.

 If screen is locked, press 

“MENU” 

for 3 seconds to unlock. Press 

“MENU”

    

  again to enter level one programming mode and adjust 

CURRENT TIME.

 

2.

 Press 

“SET/REGEN”

 to adjust hours. When you have entered the change    

  value mode, the curser will blink. Press 

“UP

 or 

DOWN” 

arrows to change  

  the hour values. Press 

“SET/REGEN”

 gain to accept the hour value and  

  advance to change the minutes value. Press 

“UP

 or 

DOWN”

 arrows to  

 

  change the minute values. Press 

“SET/REGEN”

 again to accept the minute   

  values and advance to adjust the AM/PM values. Press “ or 

“UP

 or   

 

DOWN”

 to change the 

AM/PM

 value. Press “

SET/REGEN”

 again to accept    

 the 

AM/PM

 value and exit. When you have exited the change value mode,   

  the curser will stop flashing. 

Setting Current Date

 

1.

  Press 

“DOWN”

 to advance to CURRENT DATE. 

2.

  Press the 

“SET/REGEN”

 to change the value. Press 

“UP

 or 

DOWN”

 to  

 

  change the values.

 

1.

  Plug the valve into an approved power source.

2. 

When power is supplied to the control, the screen will display “WAITING PLEASE” while it 

  finds the service position.

3.

  Start an Immediate Manual Regeneration. The valve will immediately start moving to the   

  BACKWASH position.

4.

  Open the inlet on the bypass valve slightly and very slowly allow water to enter the unit. (If the  

  water enters too quickly it will push the carbon up into the control valve and get plugged).

5.

  Once the unit has filled sufficiently that water is at least equal to the height of the top of the  

  media shut down the water for 15 – 20 minutes for the carbon to soak. Unplug the power cable.  

  After the carbon has soaked for the recommended time continue by plugging the power    

  cable back in.

6.

  Turn the water back on slowly to backwash until water runs clear to drain.

7.

  Press any button to advance to the RINSE position. Check the drain line flow. Allow the water to  

  run for 3-4 minutes or until the water is clear.

8.

  The valve will automatically advance to the SERVICE position after the RINSE cycle is complete.  

  Open the outlet valve on the bypass, then open the nearest treated water faucet and allow the  

  water to run until clear, close the tap and replace the faucet screen.

9.

  Program time, date, and number of days between regenerations into controller using  

 

  Programming Instructions

Note : Carbon filters only:

Once the unit has filled sufficiently that water is at least equal to the height of the media shut 

down the water for 15 – 20 minutes for the carbon to soak.  After the carbon has soaked for the 

recommended time continue with installation instructions.

Power the Valve and Configure to Filter

Hold 

Up

 and 

Down

 Key for 3 Seconds.

Press 

Set/Regen

 to Select the 

Value

 and

 Up/ 

Down

 Arrow to Change it. Refer to the values on the blocks that 

need to be set. Press 

Down 

Key to move to the next screen.

Setting Vacation Mode

 

1.

  Press 

“DOWN”

 to advance to 

VACATION MODE

2.

   Press the 

“SET/REGEN”

 to change the value. Press 

“UP

 or 

DOWN”

 arrows to change the values.

Programming Flow Chart

Press 

SET/REGEN

 Key and change the values using 

UP

 and 

DOWN

 Key

VACATION MODE:

 This function 

may be activated by the user during a 

prolonged absence such as vacation. 

The system will perform a brief 

backwash and rinse based on the 

advanced setting. The purpose is to 

keep the water fresh in the softener 

tank and plumbing system.

CURRENT TIME

12:01 PM

CURRENT DATE

JAN/01/2016

VACATION MODE

YES 

NO

Press 

DOWN

 key 

 

Press 

DOWN

 key 

 

SELECT ‘NO’

Key Pad Configuration: 

SYSTEM LANGAUAGE

ENGLISH

REGEN DAYS

03 DAYS

VALVE OPERATION

FILTER

BACKWASH

10 MINUTES

REGEN MODE

CALENDAR CLOCK

RAPID RINSE

10 MINUTES

REGEN TIME

12:00 AM

RESTORE DEFAULT

NO

Press 

DOWN

 key 

 

Press 

DOWN

 key 

 

Press 

DOWN

 key 

 

Press 

DOWN

 key 

 

Press 

DOWN

 key 

 

Press 

DOWN

 key 

 

Press 

DOWN

 key 

 

Press 

Menu

 Key to Exit

Содержание HT 565BM-100

Страница 1: ...system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Canada West 855 Park St Unit 1 Regina SK S4N 6...

Страница 2: ......

Страница 3: ...UCTIONS 23 BACKWASHING INSTRUCTIONS 24 SERVICING 565 VALVE 25 TIMER REPLACEMENT PISTON ASSEMBLY REPLACEMENT 26 METER ASSEMBLY REPLACEMENT For Models Manufactured afterValve Serial Date of November 201...

Страница 4: ...o pistons seals and or spacers within the control valve are not covered in this warranty due to the harsh environment s It is recommended to regularly inspect and service the control valve on an annua...

Страница 5: ...15 20 9 x 48 3 4 and 1 118 HT 565MM 150 1 5 7 0 10 0 7 0 15 20 10 x 54 3 4 and 1 144 NextSandTurbidity Filters HT 565NEX 75 0 75 4 0 6 0 3 5 3 5 8 x 44 1 2 1 90 HT 565NEX 100 1 00 5 0 8 0 4 0 3 5 9 x...

Страница 6: ...Units NTU and suspended solids mg L The sample will also be filtered through 10 micron filter paper and NTU run on a filtered sample If the NTU of the raw water exceeds 150 suspended solids exceed 15...

Страница 7: ...rapped within it to the drain 3 In Service Position The unit then returns to the In Service position While this happens water continues to enter the tank CAUTION Do not use where the water is microbio...

Страница 8: ...oss of the small parts keep them in the parts bag until you are ready to use them What is included in the box For Models 75 100 150 and 200 TO and Birm Filter Only you will expect the following Shippi...

Страница 9: ...rately in carton and bags What is included with 20 30 models 1 Tank Model 30 will get an Adapter and Oring attached to the tank 2 Control Valve with Parts Box 3 Media Boxes Qty 2 for 20 Qty 3 for 30 4...

Страница 10: ...b 3 Mar 4 April 5 May 6 June 7 July 8 Aug 9 Sep A Oct B Nov C Dec 3 Date 1 2 3 4 5 6 7 8 9 A 10 B 11 C 12 D 13 E 14 F 15 G 16 H 17 I 18 J 19 K 20 L 21 M 22 N 23 O 24 P 25 Q 26 R 27 S 28 T 29 U 30 V 31...

Страница 11: ...uld also be noted Handle the filter unit with care Damage can result if it is dropped or set on sharp uneven projections on the floor Do not turn the filter unit upside down NOTE If a severe loss in w...

Страница 12: ...llow sufficient space around the unit for easy servicing 7 If your water source is a community water supply a public water supply or you wish to bypass water used for a geothermal heat pump lawn sprin...

Страница 13: ...or underground copper pipe is tied to the copper water lines and these lines are cut during installation of the Noryl bypass valve and or poly pipe an approved grounding strap must be used between the...

Страница 14: ...trap Water Meter Raw Water To Outdoors Drain Electrical Panel Figure 1c Hard Filtered Water Cold Soft Water Hard Soft Water Water Heater Softener Drain Birm BM Filter Ground Strap Water Meter Raw Wate...

Страница 15: ...1d Outlet Inlet Figure 1d Neutralizing Filter NF Typical Installation INSTALLATION STEPS Determine the best location for your water filter bearing in mind the location of your water supply lines drain...

Страница 16: ...edia Bed Carbon Black Support Bed when supplied Fine Medium and or Coarse Gravel Plug the Riser Tube Upper Cone The riser distributor remains inside the tank seated in the depression at the bottom a b...

Страница 17: ...avel Multi Media Filter MM or nextSand Media Bed nextSand Black Support Bed when supplied Fine Medium and or Coarse Gravel NOTE Some medias like those used in NU Models are sacrificial and deplete fas...

Страница 18: ...the outside faucets but including the water heater and therefore the hot water lines being supplied with treated water NOTICE Inspect and check that the brine line plug is connected to the valve NOTI...

Страница 19: ...ater Water Heater Hot Soft Water Water Softener Filter In In Out In Out Out Cold Soft Water To Outside Faucet NOTICE THERE ARE INLET AND OUTLET LABELS ON THE VALVE PLEASE MAKE SURE TO PLUMB AS SHOWN H...

Страница 20: ...ter runs clear to drain 7 Press any button to advance to the RINSE position Check the drain line flow Allow the water to run for 3 4 minutes or until the water is clear 8 The valve will automatically...

Страница 21: ...inked drain line must be replaced d Is the drain line installed in a way that it will freeze in cold weather e If the system incorporates a standard air to water pressure tank does it have the require...

Страница 22: ...e consulted prior to performing the procedure The plumbing system and water using appliances that have been exposed even for a short time to iron fouled water need to be cleaned of the precipitated ir...

Страница 23: ...tested for pH iron and manganese on both the treated and raw water to ensure your water conditions haven t changed 3 Inspect the ControlValve and the piping between the iron filter and the pressure t...

Страница 24: ...happens contact your dealer for a replacement media bed MM nextSand under normal operating conditions the media should never need to be replaced If you experience pressure loss and cannot correct it w...

Страница 25: ...ypass system first open the valve in the bypass line then close the valves at the conditioner inlet outlet b If the conditioner has an integral bypass valve put it in the bypass position c If there is...

Страница 26: ...bly 6 Replace the piston assembly and reverse following steps in this section Remove 3 X Screws Plate Seal and Spacer Brine Valve Assembly Piston Assembly Meter Cable 1 3 2 2X Clips PISTON AND OR BRIN...

Страница 27: ...the Injector Cap Out Remove the injector assembly oring and screen Clean the injectors and replace cap 1 Disconnect the meter cable from the meter 2 Disconnect the valve from bypass by removing clips...

Страница 28: ...1 Remove the powerhead front cover 2 Remove all connections from the circuit board 3 Remove the cover from the powerhead 4 Remove the motor screws and pull the motor out from powerhead 1 3 2 1 2 1 Pul...

Страница 29: ...29 REPLACING PCBS Remove PCBs by removing the screws shown in the picture Remove front cover...

Страница 30: ...418 MM 100 9 x 48 25010034 25010036 25010035 50010005 10010043 95415 MM 150 10 x 54 25010049 25010051 25010050 50010005 10010043 95416 MM 200 12 x 52 25010058 25010060 25010059 50010005 10010043 95417...

Страница 31: ...10099 Screw ST2 9 13 Large Wafer 1 B20 60010100 Washer 3x13 1 B19 60010575 Screw ST4 2 12 Large Wafer 1 B18 60010661 Screw ST4 2 12 Large Wafer 1 B17 60010672 Magnet 3 2 7 1 B16 60010662 Brine Gear 1...

Страница 32: ...ECTOR NOZ ZLE WHITE 1 A10 INJECTOR THROAT WHITE 1 A9 60010069 SECURE CLIP S 1 A8 60010093 INJECTOR BODY 1 A7 60010657 DLFC 3 0GPM 1 A6 60010044 O RING 12 2 1 A5 60010229 QC DRAIN LINE ELBOW 1 A4 60010...

Страница 33: ...ss Shaft Inlet 1 17 O ring 30 2 65 2 16 Shaft Seal 2 15 92846 Plug Clip 2 14 Shaft Clip 2 13 60010209 Bypass Plug 2 12 60010044 O ring 12 2 2 11 60010126 Screw M4 12 2 10 60010046 SS Clip 2 9 Bush 2 8...

Страница 34: ...rol B Timer motor stopped or jammed A Remove piston assembly and inspect bore Remove foreign material and check control in various regeneration positions B Replace timer motor Press and v for 8 second...

Страница 35: ...Key for 3 Seconds Press Set Regen to Select the Value and Up Down Arrow to Change it Refer to the values on the blocks that need to be set Press Down Key to move to the next screen Setting Vacation M...

Страница 36: ...purchaser in possession of a tank that fails within 120 months provided that the water conditioner is at all times operated in accordance with speci cations and not subject to freezing General Provis...

Отзывы: