background image

Installation and

 Operation Manual

95MTS

Multi Tank Systems  

Water Softener

Canature WaterGroup Canada Inc.

855 Park St., Unit 1 

Regina, SK, S4N 6M1

Toll Free: (877) 288-9888

Canature WaterGroup U.S.A. Inc.

6353 Commerce Drive  

Whitestown, IN, 46075

Toll Free: (877) 288-9888

Содержание 95MTS

Страница 1: ...nual 95MTS Multi Tank Systems Water Softener Canature WaterGroup Canada Inc 855 Park St Unit 1 Regina SK S4N 6M1 Toll Free 877 288 9888 Canature WaterGroup U S A Inc 6353 Commerce Drive Whitestown IN...

Страница 2: ......

Страница 3: ...MTS WIRING SCHEMATICS 20 REMOVING POWER HEAD ASSEMBLY 24 REPLACE DRAIN LINE FLOW CONTROL DLFC 25 REPLACE BRINE LINE FLOW CONTROL BLFC 25 REPLACING OR CLEANING INJECTORS 26 MTS SYSTEM COMPONENTS 27 PO...

Страница 4: ...s below the point where channeling can occur the system will also recycle product water to maintain high quality BATTERY BACK UP A battery back up system allows the controller to continue metering and...

Страница 5: ...IN LINE INTOTHE SYSTEM 4 Connect the brine tanks to each valve 5 Close the isolation ball valves to each control valve Open the main bypass ball valve to the open position Slowly turn on the main wate...

Страница 6: ...ds to start a manual regeneration for that tank 4 Open the outlet isolation valve on each tank slowly and allow water to enter the unit Allow all air to escape from the unit before turning the wateron...

Страница 7: ...ton to enter the menu icon you want to edit The displayed value will begin flashing Press the UP DOWN button to adjust the value Press the SET button again to accept the change The first three menus a...

Страница 8: ...eset regeneration time a regeneration will occur The regeneration can be sched uled on certain days of the week or by set intervals of days between The outlet valve will close to prevent any raw water...

Страница 9: ...he System Setting page and return to the Main Menu If you are changing a Main PCB or Slave PCB it may be necessary to format them Format SlaveValve Restore History Data and Restore Settings are covere...

Страница 10: ...Peak Period Block Out Auxillary Outputs PROGRAMMING CONTINUED Press the UP DOWN button to highlight the desired menu con Press the SET button to enter the FeedWater menu In the FeedWater menu you can...

Страница 11: ...e on line TRIP FLOW RATE OFF This value controls the flow rate limit that the actual flow must be less than before the tank will come off line The default delay time is 5 minutes and is not adjustable...

Страница 12: ...the Auxiliary Outputs menu For detailed program ming instructions please see the Advanced Programming section Press the UP DOWN button to highlight the desired menu icon Press the SET button to enter...

Страница 13: ...of water passed through the system Press the UP DOWN button to highlight the desired menu icon Press the SET button to enter the ProductWater Polish menu The Min Flow Rate setting will control at wha...

Страница 14: ...OCK FILTER METER DELAY FILTER METER IMMEDIATE FILTER PRESSURE DROP System Type SOFTENER DEMAND FLOW FILTER TIME CLOCK FILTER METER DELAY FILTER METER IMMEDIATE FILTER PRESSURE DROP System Type SOFTENE...

Страница 15: ...on will occur Press the UP DOWN button to highlight the desired menu icon Press the SET button to enter the System Size menu In the System Size menu you can adjust the number of tanks valves in the sy...

Страница 16: ...ackwash and Rinse times The times apply to all the tanks in the system Press the UP DOWN button to highlight the desired menu icon Press the SET button to enter the Advanced Settings menu Press the UP...

Страница 17: ...s such as a pressure switch that could signal a regeneration RS OFF is the default value RS ON Immediately would signal a regeneration as soon as the remote button or switch is pushed RS ON Delay woul...

Страница 18: ...sword Salt Efficiency Salt Efficiency Settings High Efficiency 6 Lbs CF 2000 Grains Standard Efficiency 10 Lbs CF 4000 Grains High Capacity 15 Lbs CF 5000 Grains Minimum Residual 15 3 Minimum Residual...

Страница 19: ...A System Setting page will be displayed Press the MENU button to exit the System Setting page and return to the Main Menu If you wish to erase the current valve history Diagnostic Information it will...

Страница 20: ...20 Power Adaptor Outlet AC 24V 2500mA Power Adaptor Outlet AC 24V 2500mA MTS WIRING SCHEMATICS SOFTENER OR FILTER WIRING DIAGRAM...

Страница 21: ...24V 2500 MA 11040051 Valve Motor 24V AC Communication Cable 11200007681 3G Battery DC 6V Computer PLUG PC3 Front View 050420031 PLUG PC3 Back View 050420031 AUX Power In UNIT 2 UNIT X MAX 16 Valve Bod...

Страница 22: ...Valve Solenoid Valve DC 24V Polish Valve Solenoid Valve DC 24V Valve Motor 24V AC Communication Cable 11200007681 3G Battery DC 6V Computer UNIT 2 UNIT X MAX 16 Communication Cable 11200076 PLUG PC3...

Страница 23: ...et Valve Electric Ball Valve 24V DC Power Adaptor Outlet AC 24V 2500 MA 11040051 Valve Motor 24V AC Communication Cable 11200007681 3G Battery DC 6V Computer UNIT 2 UNIT X MAX 16 Communication Cable 1...

Страница 24: ...key insert Cam Hole turn the Cam anti clockwise to the backwash position Remove the Connector Remove the Locking Bar Pull the Power Head Assembly outwards Automatically remove the Power Head Assembly...

Страница 25: ...OL BLFC To replace the Drain Line Flow Control DLFC Remove the Drain Line Clip Pull the Drain Line Elbow Assembly outward Pull the DLFC Holder outward from the Drain Elbow Replace the DLFC To replace...

Страница 26: ...Injector Cover assembly outward Slightly pull out the Screen Replace the Injector Nozzle Slightly pull out the Air Disperser Replace the InjectorThroat Reassemble using the reverse procedure Sediment...

Страница 27: ...BNT950 MTS SLAVE 4 C W 1 25 BALLVALVE 10010056 1 MTS MAIN CONTROLLER 60010182 MTS COMMUNICATION CABLE 2M 60010197 MTS COMMUNICATION CABLE 6M 60010083 MTS POWERTRANSFORMER 60010083 120V INPUT 24V OUTPU...

Страница 28: ...28 A22 A20 A21 A18 A19 A13 A14 A15 A16 A17 A12 A11 A28 A30 A31 A10 A7 A8 A9 A3 A6 A2 A4 A5 A1 A32 A38 A32 A33 A34 A35 A36 A37 A23 A24 A25 A26 A27 A39 A40 A41 A29 POWER HEAD EXPLODED VIEW...

Страница 29: ...ring 8 2 4 A22 05040038 95 95MTS Cable Jaket 2 A23 60095611 Meter Cable 1 A24 26010028 O Ring 28x2 65 1 A25 60095031 BrineValve Connector 1 A26 60095606 O ring 4 1 5 1 A27 60095013 Brine Piston Rod 1...

Страница 30: ...47 B48 B49 B50 B1 B2 B3 B4 B5 B6 B7 B10 B11 B51 B52 B53 B3 B4 B39 B40 B41 B42 B43 B17 B17 B14 B16 B44 B29 B30 B31 B32 B34 B35 B36 B37 B32 B38 B16 B19 B20 B21B22B23B24B25 B16 B14 B33 B14 B14 B17 B45 B4...

Страница 31: ...26 Meter Assembly B19 60010225 Magnet 4 3 B20 95 Meter B21 Meter PinTop Bush B22 Meter Pin Bush B23 Meter Ball B24 Meter Pin B25 Impeller Holder B27 60010214 Valve Connector NPT 1 25 B28 60010216 O ri...

Страница 32: ...scription DLFC Options 60010144 2 9 5 gpm Flat 60010145 3 12 5 gpm Flat 60010146 4 16 5 gpm Flat 60010142 7S 7 0 gpm Flat Connector Options 60010213 Valve Connector NPT 1 60010215 Valve Connector NPT...

Страница 33: ...ntrol DLFC button Check for proper ow rate 1 Plugged injector or screen Clean parts 2 Valve not regenerating Replace circuit board motor or control 3 Foreign material in brine valve Clean parts 4 Unit...

Страница 34: ...ee from damage Flow control s cleaned and free from damage Piston clean and free from damage Confirm ball valve s fuction if applicable Brine float cleaned and free of damage Brine Tank cleaned Flow m...

Страница 35: ...oor each tank Treated Water Hardness each tank Brine tank overflow connection s installed to drain and clean Total system treated water For warranty claims Canature WaterGroup reserves the right to as...

Страница 36: ...2 Tank 3 Tank 4 Date Height of brine from ground Number of regenerations completed For warranty claims Canature WaterGroup reserves the right to ask for this maintenance sheet Failure to provide this...

Страница 37: ...and brine Date Date Brine tank full of salt and brine Raw water hardness Treated hardness system Alarms Alarms For warranty claims Canature WaterGroup reserves the right to ask for this maintenance sh...

Страница 38: ...ponding softener tank Weight of Salt added Date Number of regeneration s for corresponding softener tank Weight of Salt added For warranty claims Canature WaterGroup reserves the right to ask for this...

Страница 39: ......

Страница 40: ...the fiberglass tank has a tripod base it must have been properly and securely attached to the floor If not done or improperly installed the tank warranty will be void At our sole discretion we will re...

Отзывы: