Key Locked,
Press
[ ]
Key for 5S
to Unlock
Flow Rate : 00.00GPM
25-DEC-2025 06:30AM
Remain:001234GAL
Capacity:001234GAL
Backwash
Any Key 3S to Next
10:00
2.
Press and hold
button three (3
)
to start
Manual Regeneration process.
3.
Press and hold any button to advance to
Backwash.
4.
The display will indicate the time
remaining.
ALLOW TO FINISH FULL CYCLE.
50%
1.
Press and hold
button one (1
),
the display will read
“PRESS
[ ]
5 Seconds to Unlock”
.
After 5 seconds, the display will
beep confirming unlock.
START-UP INSTRUCTIONS
STEP 2. PURGE AIR FROM THE UNIT
MANDATORY
Be sure to open the bypass inlet very slowly. Do NOT
FULLY open the bypass inlet until there is a steady
stream of water at the drain as this will result in media
being expelled from the unit
NOTE
If severe loss in water pressure is observed when the
softener unit is initially placed in service, the softener
tank may have been laid on its side during transit. If this
occurs, backwash the softener to ‘reclassify’ the media.
Now that your water softener is plumbed into position it is time to start up and program the unit.
STEP 1. ADD WATER TO BRINE TANK
1.
Open the brine tank/cabinet salt lid and fill with water until there is approximately 1” [25.4 mm] of water above
the grid plate.
2.
If there is no grid plate, fill the tank with 3” [75 mm] of water.
Do NOT add salt to the brine tank at this time.
5.
Open the bypass inlet very slowly
until there is a steady stream of water at the drain. Opening the bypass inlet too quickly could result
in resin being expelled from the unit and into the plumbing lines. With the valve in the backwash position the unit will purge air from the
system, sending it to the drain. This may take longer than the programmed backwash cycle time, so unplug the power so that the valve will
remain in the backwash position.
6.
With the bypass inlet now fully open, let the system run until all the air is purged and there is a steady stream of water at the drain.
7.
Reconnect the power, press and hold any button to advance to the refill position and allow the unit to refill to 1” [25.4 mm] above the grid
board or 3” [76.2 mm] of water in cabinet models – this may require manually advancing the unit through its cycles more than once.
Alternatively, you can press and hold any button to advance to the service position and manually add the required amount of water
as described in step 1.
8.
Allow the unit to return to the SERVICE position.
9.
Slowly open the bypass OUTLET knob until fully open.