KNOW THIS BEFORE STARTING YOUR INSTALLATION

 

Read this manual thoroughly to become familiar with  

 

the softener and its capabilities before installing or  

 operating. 

 

Failure to follow instructions could result in  

 

personal injury, property damage or death.

 

 

This manual will assist you in getting the most out of  

 

your new softener. 

 

The installation of this softener MUST be in accordance  

 

with all electrical and plumbing authorities, as well as all  

 

applicable local codes and ordinances.

 

Check with your local public works department for  

 

plumbing and sanitation codes. 

 

In the event that the codes conflict with any content in  

 

this manual – the local codes should be followed. 

 

Installation by a licensed plumber or certified water  

 

treatment professional is recommended. 

 

This softener is designed to operate on pressures of  

 

30 -125 psi. 

 

If the water pressure is higher than 125 psi, use a   

 

pressure reducing valve ahead of this softener. 

 

It is not uncommon for sediment, precipitated  

 

iron, or hardness to be present in water supplies.  

 

Precipitated minerals or sediment can cause damage to  

 

the seals and piston.

 

If precipitated minerals or sediment are present in  

 

your water supply this will be considered a harsh  

 

environment. The seals and piston would not be covered  

 

by warranty, stated or otherwise.  

 

Do NOT use water that is microbiologically unsafe  

 

without adequate disinfection before or after  

 

this system. 

 

This softener is capable of operating at temperatures  

 

between 4 °C – 43 °C or (40 °F -110 °F).  

 

Do NOT expose softener to freezing temperatures or  

 vacuum. 
 

Discharge lines exposed to freezing temperatures should  

 

be positioned with a downward slope. 

 

Do NOT expose softener to direct sunlight. 

 

Do not use this softener on hot water supply lines. 

 

Avoid pinched O-rings during installation by applying the  

 

silicone-based lubricant supplied. Part #92360. 

 

It is recommended to inspect and service the control  

 

valve on an annual basis.  

 

Cleaning and or replacement of piston, seals,  

 

and or spacers may be necessary depending on    

 

the raw water quality.  

 

Your installer can provide a maintenance kit for this  

 purpose. 

 

Rural applications should have a water analysis annually  

 

prior to system checkup or repair. 

 

Chlorine bleach and common iron control chemicals may  

 

generate toxic fumes when mixed. 

 

Always wear appropriate safety gear, such as safety  

 glasses.

 

NOTE

When dissolved iron is present, use the  

Problem Water Injector Kit. (See Start-up Instructions: Problem 

Water Injector Kit.)

 

NOTE

Check with your local public works department for applicable 

local plumbing and sanitation codes. Follow local codes if they 

differ from the standards used in this manual. Otherwise,  

carefully follow the instructions in this manual. Canature is not 

liable for any non-compliance with local requirements

NOTICE

The warranty provided gives you specific legal rights and  

otherwise limits your legal rights to the extent permitted by law. 

By installing and/or using this product, you are accepting these  

limits on your legal rights. Canature is NOT responsible for losses, 

injury, or death resulting from a failure to observe these safety 

precautions, or misuse or abuse of the equipment.

Содержание 85TA

Страница 1: ...operation 4 Avoid pinched O rings during installation by applying NSF certified lubricant to all seals provided with install kit 5 This system is not intended for treating water that is microbiologica...

Страница 2: ...WORKS 6 FEED WATER PARAMETERS 6 UNPACKING INSPECTION 7 BEFORE INSTALLATION 8 PREPARATIONS 9 PLANNING YOUR INSTALLATION 12 INSTALLATION STEPS 14 UNDERSTAND THE SCREEN KEYPAD CONFIGURATION 16 START UP I...

Страница 3: ...he warranty The warranty provided gives you specific legal rights and otherwise limits your legal rights to the extent permitted by law By installing and or using this product you are accepting these...

Страница 4: ...umber serial number and valve serial number in the Records Contacts section as they will be important if you need to troubleshoot FIND AND RECORD VALVE TYPE SERIAL NUMBERS RECORDS CONTACTS YOUR DEALER...

Страница 5: ...or 40 F 110 F Do NOT expose softener to freezing temperatures or vacuum Discharge lines exposed to freezing temperatures should be positioned with a downward slope Do NOT expose softener to direct su...

Страница 6: ...lease the sodium and exchange them with the hardness ions The resin beads and the softener must be regenerated as these ions are exchanged and are used up Regeneration is accomplished by rinsing the r...

Страница 7: ...ON CONTINUED WARNING RISK OF CHOKING Discard all leftover parts and packaging materials after installation Small parts could be a choking hazard NOTE Canature is NOT responsible for damages in transit...

Страница 8: ...to the pipe as excessive heat can damage them Softener resins will degrade in the presence of chlorine or chloramines above one 1 ppm If you have anything in excess of this amount you will experience...

Страница 9: ...der part 99003 separately for your own funnel Slowly add the gravel Depending on the type of system add the resin or media next Support Bed Gravel Media MANDATORY Wear a Dust Mask Airborne particles c...

Страница 10: ...ove the tape from the top of the riser tube Carefully position the valve over the riser tube inserting riser into the internal O ring Turn the valve clockwise into the threads of the tank until secure...

Страница 11: ...ide the brine tank 6 For installation of brine tank at the installation site pull the other end of the brine tube from the hole on the brine tank The completed assembly is below 3 Place the brine grid...

Страница 12: ...to a floor or laundry tub drain and a 120 volt AC electrical outlet 6 Softeners should be located before the water heater on the supply line If closer than three 3 metres 10 feet install a check valv...

Страница 13: ...ail Drain Elbow Assembly T connection 3 8 BrineTube 5 8 Drain Line 5 8 Overflow Line Optional Floor Drain Optional Pipes Fixed Structure BrineValve Connector Detail Laundry Drain AC 120V 10A Current P...

Страница 14: ...plied lubricant 92360 to the O rings of the fittings 4 Connect the supplied straight or elbow plumbing adaptors to the bypass with red clips 5 Connect the inlet and outlet of the water softener to the...

Страница 15: ...lease make sure bypass knobs are completely open otherwise the untreated water may enter through the valve SERVICE INLET OUTLET INLET OUTLET BYPASS INSTALLATION STEPS CONTINUED 7 Attach the brine line...

Страница 16: ...press and hold the MANUAL REGEN key the value changes to zero PARAMETER DESCRIPTION JULY 17 2023 8 30 PM Month Day Year Time U1 ONLINETOTAL 1500 GAL The current status of Unit 1 ONLINE or STANDBY The...

Страница 17: ...grid plate fill the tank with 3 75 mm of water Do NOT add salt to the brine tank at this time NOTE If severe loss in water pressure is ob served when the softener unit is initially placed in service t...

Страница 18: ...ganese x 8 __ grains of hardness These numbers can be found on your water analysis report and the equivalent grains of hardness should be added to your total hardness number The new sum of these numbe...

Страница 19: ...on one 1 for three seconds 3 to unlock 2 After three 3 seconds the display will beep confirming unlock 3 Press and hold button one 1 for three seconds 3 until you hear a beep This will unlock the SETT...

Страница 20: ...rollers will operate with one tank in service and the second tank off line for regeneration or ready in standby Based on peak flow water usage the trip points can be set accordingly EXAMPLE U5T30S D3T...

Страница 21: ...hen it regenerates Salt Water Congratulations Start Up Instructions are now complete the unit is operational NOTE See Problem Water Injector Kit if you have iron in your water and are installing an up...

Страница 22: ...the water heater OFF and shut the heater inlet water valve OFF 2 Drain hot water tank completely OPEN the InletWaterValve allowing the heater tank to be refilled with iron free water Continue flushin...

Страница 23: ...requency Maintenance materials Please see Common Spare Parts CARE OF YOUR SOFTENER To retain the attractive appearance of your new water softener occasionally clean it with a mild soap solution Do NOT...

Страница 24: ...s happen or the unit fails to regenerate for any other reason correct the problem first then regenerate the unit manually Regenerate two times in a row to restore the reserve capacity and bring the me...

Страница 25: ...sy Feeder for proper operation A ResCare Easy Feeder is essential if your raw water contains measurable amounts of Iron 2 Mark the location of the holder and drill 1 Measure 2 inches from the top of t...

Страница 26: ...tle 45128 Rust Out 50 lb Pail USA only Item Description 55030005 Easy Feeder 0 5 oz day Feeder 55030006 Easy Feeder 1 0 oz day Feeder 55030007 Easy Feeder Starter Kit oz with 64 oz ResCare SERVICING Y...

Страница 27: ...shown Place spacer in then a seal and repeat until finishing with a seal 6 Lubricate the piston assembly with silicone lubricant Part 92360 and then replace the Piston Assembly Remove 3 X Screws Plat...

Страница 28: ...salt and silt will restrict or clog the injector A clean water supply and pure salt will prevent this from happening The injector assembly is located on the right side of the control valve when facing...

Страница 29: ...will restrict or clog the injector A clean water supply and pure salt will prevent this from happening The injector assembly is located on the right side of the control valve when facing your softener...

Страница 30: ...tion Unplug power for 30 seconds then reconnect If the alarm continues contact your authorized installer UNIT REGENERATES BUT DOES NOT USE SALT Drain line flow control is plugged Clean or replace inje...

Страница 31: ...ed HALL SENSOR ERROR CODE Power surge Unit is in normal home position showing Hall Sensor Error 1 Unplug for one 1 minute 2 Plugin 3 Initiate Manual Regen if the error reoccurs Circuit failure Transfo...

Страница 32: ...fiberglass tank has a tripod base it must have been properly and securely attached to the floor If not done or improperly installed the tank warranty will be void At our sole discretion we will repai...