9
Programming Instructions
CHANGE SETTINGS
To change settings press the
SETTINGS key for 3 seconds.
The first screen to be displayed
will be the TIME OF DAY. To ad-
just the HOUR values, use the UP
or DOWN key. To advance to the
MINUTE values, press the SET-
TINGS key again. After adjusting
each value using the UP or
DOWN keys, continue advancing
to the next value or screen by
pressing the SETTINGS key.
TIME OF DAY, YEAR, MONTH,
DAY,
Time of day is for normal opera-
tion of system and the scheduling
of the regeneration time. The
date is used in a diagnostic func-
tion to track the last time the sys-
tem regenerated.
SET HARDNESS
This value is the maximum com-
pensated water hardness in
grains per gallon of the raw water
supply. It is used to calculate the
system capacity. If Ferrous Iron
is present add 4 gpg for every 1
ppm of Ferrous Iron.
SET PEOPLE
This value is the number of peo-
ple living in the home. It is used
to calculate the amount of water
needed for daily use and the re-
serve capacity of the system.
SALT SETTING
Choose HIGH EFFICIENCY to min-
imize salt usage. Your system
will regenerate a little more often
but your salt usage can be re-
duced by 20% compared to the
STANDARD setting.
Choose STANDARD when you
need to maximize your capacity
but still operate the system with
good efficiency.
Choose IRON & MN if you have
problem water containing these
minerals. The high salt setting
will be needed since these miner-
als are more difficult to clean out
of the resin bed. Note: A resin
cleaner will also need to periodi-
cally added to the brine tank to
insure proper operation.
WATER TYPE
This setting will determine if the
BACKWASH OVERIDE function
will be on or off. Select MUNICI-
PAL if the water source is clean
(<1NTU turbidity) and the system
will skip the back wash cycle
based on the setting in BACK-
WASH OVERIDE.
Select WELL / OTHER if any Iron
or Manganese is present or if the
water source is not clean (<
1NUT turbidity). The system will
back wash every time.
REGEN TIME
This setting determines the time
of day to perform a scheduled
regeneration.
NAME & PHONE
Enter in member name and
phone number. This will be dis-
played on the main pages.
The factory setting for WATER TYPE is WELL / OTHER. Do not adjust this setting until after
start-up is complete. If the setting is changed to MUNICIPAL before start-up, the back
wash cycle will be skipped.
Settings
Press SETINGS key (3 SECONDS / BEEP)
TIME OF DAY
12:01 PM
YEAR
2012
MONTH
AUGUST
DAY
21
SET HARDNESS
20 GRAINS
SET PEOPLE
4
SALT SETTING
HIGH EFFICIENCY
STANDARD
IRON & MN
WATER TYPE
MUNICIPAL
WELL / OTHER
REGEN TIME
2:00 AM
NAME
STAR
PLUMBING
PHONE
TEL (552)
764-1234
PROGRAMMING
COMPLETE