Automatic Hard Water Bypass During Regeneration 

The regeneration cycle can last 30 to 180 minutes, after which soft water service will be re-

stored. During regeneration, hard water is automatically bypassed for use in the household. 
Hot water should be used as little as possible during this time to prevent hard water from 
filling the water heater. This is why automatic regeneration is set for sometime during the 
night and manual regenerations should be performed when little or no water will be used in 

the household. 
 
Normal regeneration time is 2:00 AM. 

New Sounds 

You may notice new sounds as your water softener operates. The regeneration cycle lasts 

up to 180 minutes. During this time, you may hear water running intermittently to the drain. 

When the system capacity is near exhausted, a regeneration is necessary to restore the sys-

tem to full capacity.  The table below explains the regeneration steps. 

Regeneration Process and Precision Brining 

System Configuration 

Step  Name 

Description 

 

 

 

#1 

Brine 

The brine solution is introduced slowly to the tank flowing  down through the 
ion exchange resin pushing the hardness out to drain and restoring system ca-
pacity. 

#2 

Back Wash 

Fresh water is introduced to the bottom of the tank flowing upwards expand-
ing the ion exchange resin to rinse out any dirt or small particles to the drain 
and to un-compact the bed to restore full service flow rates. 

#3 

Rinse 

Fresh water is introduced from the top of the tank down flowing down through 
the ion exchange resin rinsing any excess brine solution out to the drain. 

#4 

Refill 

A fixed amount of soft water is added to the salt tank to prepare fully saturat-
ed brine for the next regeneration.   

Suggested Downflow Softener Valve Configurations 

Tank Size 
(Diameter) 

Injector Set 

Brine Line 
Flow Contol 
(BLFC) 

Drain Line 
Flow Control 

9" 

#1 White 

0.3 GPM 

#2 (2.0 GPM) 

10" 

#1 White 

0.3 GPM 

#3 (2.4 GPM) 

12" 

#2 Blue 

0.3 GPM 

#4 (3.5 GPM) 

14" 

#3 Yellow 

0.3 GPM 

#7 (5.0 GPM) 

Содержание 185DF Series

Страница 1: ...E WARRANTY BEFORE YOU BEGIN INSTALLATION READ THIS ENTIRE MANUAL THEN OBTAIN ALL THE MATERIALS AND TOOLS 1 Avoid pinched O rings during installation by applying provided with install kit NSF certified...

Страница 2: ...g water that is microbiologi cally unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to minimize the...

Страница 3: ...re may exceed the maximum Use a pressure reducing valve to reduce the pressure Softener resins may degrade in the pres ence of chlorine or chloramines above 2 ppm If you have chlorine or chloramines i...

Страница 4: ...fficiency Salt Used Per Regeneration 2 3 lbs 3 0 lbs 2 3 lbs 3 0 lbs 3 75 lbs 6 0 lbs 9 0 lbs Water Used Regeneration 22 7 gal 28 3 gal 22 6 gal 31 6 gal 39 5 gal 60 9 gal 102 2 gal Hardness Removal G...

Страница 5: ...hed 6 foot power cable Extension cables are available Be sure the electric outlet and transformer are in an in side location to protect from wet weather If installing in an outside location you must t...

Страница 6: ...his could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub or floor drain This...

Страница 7: ...7 Installation Twin Tank...

Страница 8: ...Allow the valve to refill for the full amount of time as dis played on the screen to insure a proper brine solution for the next regeneration 7 The valve will automatically advance to the SERVICE posi...

Страница 9: ...need to maximize your capacity but still operate the system with good efficiency Choose IRON MN if you have problem water containing these minerals The high salt setting will be needed since these mi...

Страница 10: ...EXT REGEN 06 DAYS LAST REGEN 9 24 12 TOTAL REGENS 10 TOTAL GALLONS 001590 GAL OVER RUN TOTAL 0500 GAL CURRENT 1 5 GPM PEAK 6 5 GPM DELAYED REGEN OFF REGEN TIME 2 00 AM REFILL TIME 3 00 MIN VALVE MODE...

Страница 11: ...table below explains the regeneration steps Regeneration Process and Precision Brining System Configuration Step Name Description 1 Brine The brine solution is introduced slowly to the tank flowing do...

Страница 12: ...only NUGGETor PELLET water softener salt Check the salt level monthly It is im portant to maintain the salt level above the water level To add salt simply lift the salt lid and add the salt directly...

Страница 13: ...ontrol valve body 3 Carefully remove the assembly and disassemble as shown in above figure 4 The injector orifice is removed from the valve body by carefully turning it out with a large screwdriver Re...

Страница 14: ...t the BLFC holder apart and remove the flow washer 4 Reassemble using the reverse procedure TIP Markings on the BLFC washer should face the direction as shown here Replacing Drain Line Flow Control DL...

Страница 15: ...a to form or grow However during shipping storage installing and operating bac teria could get into the softener For this reason sanitizing as follows is suggested when in stalling Sani System Liquid...

Страница 16: ...Quantity 60010020 3 4 NPT ELBOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE C...

Страница 17: ...STON ASSEMBLY 60010035 INJECTOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032...

Страница 18: ...1 5030013 O Ring 30 2 65 A20 1 5056063 O Ring 78 74 5 33 A21 1 26010103 O Ring 25 3 55 A22 1 7060007 Valve Bottom Connector A23 1 13000426 Screw ST2 9X13 Large Washer A24 2 5031022 O Ring 32 3 A25 1...

Страница 19: ...19 Power Head Exploded View...

Страница 20: ...Drive Gear B08 1 13000426 Screw ST2 9X13 Large Washer A24 2 5056139 Washer 3x13 B09 1 5030007 BNT85 Main Gear B10 1 5030005 BNT185 Housing B11 1 5031017 BNT85HE Brine Gear Downflow B12 1 5010023 Magn...

Страница 21: ...ne flow control DLFC button Check for proper flow rate 1 Plugged injector or screen Clean parts 2 Valve not regenerating Replace circuit board motor or control 3 Foreign material in brine valve Clean...

Страница 22: ...d shall be from the date thereof Life Time Warranty on Mineral Tanks and Brine Tanks WaterGroup will provide a replacement mineral tank or brine tank to any original equipment purchaser in possession...

Отзывы: