background image

PLF SERIES

 

 

WALL EXHAUST FAN

M0017_PLF SERIES_02_21_2023

Page 5 of 5 

Canarm Ltd. - Corporate Head Office 

2157 Parkedale Avenue, PO Box 367 
Brockville, Ontario Canada   K6V 5V6 
Tel: (613) 342-5424   Fax: (613) 342-8437 

 

BELT DRIVE FAN

WARNING

 

MOTORS ARE EQUIPPED WITH AUTOMATIC OVERLOAD PROTECTION AND 
MAY RESTART WITHOUT WARNING. ALWAYS DISCONNECT POWER BEFORE 
ATTEMPTING TO SERVICE, OR REMOVING SHUTTER.

ACCESSORIES

Canarm provides a full line of controls from simple on/off thermostats to sophisticated multiple staging controllers and PC based controllers. 
Winter covers are available for colder climates where the fan is shut down for the winter. Performance enhancing cones are available for 
24" to 36" sizes that boosts air moving performance and efficiency by approximately 10% for PLF36 fans, and 15% for PLF24 fans. 
Weather Hoods are available for 12” to 24” models.

Belt drive fans are equipped with an automatic belt tensioner. The rotary tensioner will compensate for any wear or stretching of the belt. 
No adjustments should be necessary. Belt will however wear after extensive use. Fan performance will be sacrificed if worn belt is used. 
Listen for belt “squeeling” on startup. This would indicate that the belt requires changing or tightening. Tightening can be done by moving 
the screw location on the tensioner bracket. 

(see figure 4) 

(Although we recommend replacing the belt). 

 

Lubrication: 

Belt drive fans are provided with bearing blocks that are pre-lubricated & sealed. They have a double contact seal and steel 

slinger that prevents most contamination. However, since the bearings are to operate in very damp and dirty conditions, re-lubrication is 
recommended. The grease fitting of the unit should be carefully cleaned before use and the grease should be introduced slowly. Under 
normal conditions, the bearings only need re-lubrication every 3 years. Nonetheless, we recommend that each bearing receive one pump 
from a grease gun (or until fresh grease is pushed out), every time the unit is washed down (especially if detergent is used.) 
 

NOTE: 

Use NLGI2 lithium base grease to ensure compatibility with original grease. 

 

CAUTION: Do not use pneumatic grease guns. Slowly introduce grease with manual gun, otherwise bearing seals 

     

will be destroyed. 

Arthur Manufacturing Facility

 

#7686 Concession 16, RR 4 

Arthur, Ontario Canada.  N0G 1A0  

Tel: (519) 848-3910.  Fax: (519) 848-3948   

 

www.canarm.com                       

                            [email protected]                

Figure 4 
Adjusting Belt Tensioner

NOTE:

 Remove belt before making adjustments.

Remove Bolt

1

3

2

Change screw hole placement. Moving 
screw towards belt will increase tension.

Use screw from step 2 as pin location for 
tensioner. Reassemble bolt from Step 1.

Содержание PLF Series

Страница 1: ...ns INSTALLATION OR PRODUCT PROBLEMS DO NOT RETURN TO STORE OF PURCHASE CONTACT CANARM SERVICE AT 1 800 265 1833 CANADA 1 800 267 4427 U S A 1 800 567 2513 EN FRAN AIS MONDAY TO FRIDAY 8 00 5 00PM E S...

Страница 2: ...ips 8 nylon washers 8 10 24 x 3 4 stainless steel screws and 8 nylon insert nuts This hardware is for the turn clips that hold the shutter assembly in place Assemble the 8 turn clips to the pre drille...

Страница 3: ...to the motor On some models there are holes punched along the lengths of the arms It is recommended that you use cable ties provided in hardware bag to attach cable to arm see Figure 2 Make sure the c...

Страница 4: ...p should occur on blade motor guard and louvers for proper fan operation and to prevent premature failure The complete fan should be washed down on a regular basis to maintain the high efficiency of t...

Страница 5: ...ng or tightening Tightening can be done by moving the screw location on the tensioner bracket see figure 4 Although we recommend replacing the belt Lubrication Belt drive fans are provided with bearin...

Страница 6: ...A CLIENT LE CHEZ CANARM AU 1 800 265 1833 CANADA 1 800 267 4427 USA 1 800 567 2513 EN FRAN AIS DU LUNDI AU VENDREDI ENTRE 8 00H ET 17 00H HNE PRECAUTIONS G N RALES Les pi ces rotatives poulies arbre e...

Страница 7: ...au bras de support du moteur Le sac contient 8 attaches tournantes 8 rondelles de nylon 8 vis en acier inoxydable 10 24 x et 8 crous d insert en nylon Ce mat riel est destin aux attaches tournantes q...

Страница 8: ...TILATEUR D EXTRACTION MURAL M0017_PLF SERIES_FR_02_21_2023 Page 3 de 5 CONNEXIONS LECTRIQUES MISE EN GARDE TOUS LES TRAVAUX LECTRIQUES DEVRONT TRE EX CUT S PAR UN LECTRICIEN QUALIFI MISE EN GARDE FERM...

Страница 9: ...t et arri re et des protections avant pour une meilleure performance dans le d placement de l air Le moteur doit tre maintenu propre pour viter une surchauffe et une panne pr matur e Comme pour tous l...

Страница 10: ...d Si ge Social 2157 Parkedale Avenue PO Box 367 Brockville Ontario Canada K6V 5V6 Tel 613 342 5424 Fax 613 342 8437 MISE EN GARDE LES MOTEURS SONT QUIP S D UNE PROTECTION AUTOMATIQUE CONTRE LES SURCHA...

Отзывы: