![CanadianSolar CSI-75K-T480GL03-U Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/canadiansolar/csi-75k-t480gl03-u/csi-75k-t480gl03-u_installation-and-operation-manual_4093722039.webp)
Dimensions (W*H*D)
Weight
1065*567*344.5 (mm) / 41.9*22.3*13.5 (inch)
3/PE~480
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Full load MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Max.efficiency
EU efficiency
MPPT efficiency
Model
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Noise emission
Cooling concept
Max.operation altitude
AC connection
Compliance
DC connection
1000
9*32
9*50
9/18
0.8leading~0.8lagging
60
98.7%
98.3%
99.5%
Transformerless
<
2W
-13...140
℉
/ -25
℃
...+60
℃
0~100%
Display
Communication connections
Warranty
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
MC4
OT Terminal connectors
(
Max.185mm²
)
LCD,2x20Z
10 years standard (extend to 20 years)
600
80000
80000
80000
96.2
THDi (at rated output power)
<3%
Start-up voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
180...1000
550...850
195
9. Specifications
9. Specifications
TYPE 4X
≤
65dB(A)
Intelligent redundant cooling
13120ft / 4000m
UL 1741, IEEE 1547, UL 1699B, UL 1998,
FCC, UL 1741SA, California Rule 21
RS485, Optional: Wifi, PLC, Ethernet
.74.
.75.
Dimensions (W*H*D)
Weight
1065*567*344.5 (mm) / 41.9*22.3*13.5 (inch)
3/PE~480
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Max.efficiency
EU efficiency
MPPT efficiency
Model
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Noise emission
Cooling concept
Max.operation altitude
AC connection
Compliance
DC connection
1000
10*32
10*50
10/20
0.8leading~0.8lagging
60
98.8%
98.2%
99.5%
Transformerless
<
2W
-13...140
℉
/ -25
℃
...+60
℃
0~100%
TYPE 4X
≤
65dB(A)
Intelligent redundant cooling
13120ft / 4000m
Display
Communication connections
Warranty
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
MC4
OT Terminal connectors
(
Max.185mm²
)
LCD,2x20Z
10 years standard (extend to 20 years)
600
90000
90000
90000
108.3
THDi (at rated output power)
<3%
Start-up voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
180...1000
195
UL 1741, IEEE 1547, UL 1699B, UL 1998,
FCC, UL 1741SA, California Rule 21
Full load MPPT voltage range (Volts)
550...850
RS485, Optional: Wifi, PLC, Ethernet
85kg / 187lbs
85kg / 187lbs
CSI-80K-T480GL03-U
CSI-90K-T480GL03-U