NOTE:
If the inverter displays any alarm message as listed in Table 8.1; please
turn off the inverter (refer to Section 5.2 to stop your inverter) and wait for 5
minutes before restarting it (refer to Section 5.1 to start your inverter). If the
failure persists, please contact your local distributor or the service center.
Please keep ready with you the following information before contacting us.
1. Serial number of Canadian Solar Single Phase Inverter;
2. The distributor/dealer of Canadian Solar Single Phase Inverter (if available);
3. Installation date.
4. The description of problem (i.e. the alarm message displayed on the LCD and the status
of the LED status indicator lights. Other readings obtained from the Information submenu
(refer to Section 6.2) will also be helpful.);
5. The PV array configuration (e.g. number of panels, capacity of panels, number of strings
, etc.);
6. Your contact details.
DCinj-FAULT
High DC injection current
1.Check AC and DC connection
2.Check inverter inside cable connection.
1.Restart inverter or contact installer.
1.Restart inverter or contact installer.
Table 8.1 Fault message and description
Alarm Message
Failure description
Solution
ILeak-PRO
01/02/03/04
Leakage current protection
RelayChk-FAIL
Relay check fail
.41.
.40.
8. Trouble Shooting
47...52 or 57...62
Max. DC input voltage (Volts)
Rated DC voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Rated grid frequency (Hertz)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
MPPT efficiency
Max. DC input power (Watts)
Model
Dimensions
Weight
Topology
Operating ambient temperature range
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
Designed lifetime
Connention
Grid connection standard
Operating surroundings humidity
310W*373H*160D (mm)
600
11
17.2
1/1
220/230
0.8leading~0.8lagging
50/60
97.2%
96.5%
>99.5%
8.5kg
Transformerless
IP65
<20 dBA
Natural convection
4000m
>20 years
-
25
℃...
60
℃
Display
Monitoring
Communication connections
Warranty Terms
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
0...100% Condensing
Mc4 connector and Ip67 rated plug
LCD, 2×20 Z.
WiFi or GPRS
4 pins RS485 connector
5 Years STD (Extendable to 20 Years)
En50438, G83/2, G98, G99, AS4777.2:2015,
VDE0126-1-1, IEC61727, VDE N4105
200
700
800
800
3.2/3.0
900
THDi (at rated output power)
<3%
50...500
Start-up voltage (Volts)
60
Max short circuit input current (Amps)
CSI-700TL1P-GI-FL