EN-Rev IM/GN-BM-EU/1.21 Copyright © July 2019. Canadian Solar Inc.

·  

Do not

 carry modules on your head.      

·  

Do no

t drop or place objects (such as tools) on the mo-

dules.  

·  

Do not 

use sharp instruments on the modules. 

·  

Do not 

leave modules unsupported or unsecured. 

·  

Do not 

change the wiring of bypass diodes.

·  Keep all electrical contacts clean and dry at all times.

PRODUCT IDENTIFICATION

·  Each module has two identical barcodes (one in the 

laminate under the front glass, the second on the rear 
side of the module) that act as a unique identifier. Each 
module has a unique serial number containing 14 di-
gits.

·  A nameplate is also affixed to the rear glass of each 

module. This nameplate specifies the model type, as 
well as the main electrical and safety characteristics of 
the module.

5.0  MODULE INSTALLATION

                   PRECAUTIONARY MEASURES AND 
                   GENERAL SAFETY

·  Prior to installing modules please obtain information 

about any requirements and necessary approvals for 
the site, installation and inspection from the relevant 
authorities. 

·  Check applicable building codes to ensure that the con-

struction or structure (roof, facade, support, etc.) can 
bear the module system load. 

·  Canadian Solar Inc. bifacial double glass solar modules 

(BiKu and BiHiKu) have been qualified for Application 
Class A (equivalent to Safety Class II requirements). Mo-
dules rated under this class should be used in systems 

operating at voltage above 50V or power above 240W, 
where general contact access is anticipated.

·  Canadian Solar Inc. bifacial double glass modules have 

been certified as Type 3 or Type 13 according to UL 1703 
and as Class A for fire performance according to IEC 
61730-2, please refer to the datasheet or the product 
nameplate for the detailed types.

·  Consult your local authority for guidelines and require-

ments for building or structural fire safety.

UL 1703 SYSTEM FIRE RATING REQUIREMENTS

·  The fire rating of this module is only valid when the pro-

duct is installed as specified in the mechanical mounting 
instructions.

·  When installing the modules, ensure the assembly is 

mounted over a fire resistant roof covering rated for the 
application. 

·  A photovoltaic system composed of UL1703 certified mo-

dules mounted on a UL2703 certified mounting system 
should be evaluated in combination with roof coverings 
in accordance with UL1703 standard, with respect to mee-
ting the same fire classification as the roof assembly. 

·  Mounting systems with a System Fire Class Rating (Class 

A, B or C), tested in conjunction with fire rated “Type 3” or 
“Type 13” rated modules, are considered acceptable for 
use with Canadian Solar Inc. modules, provided the moun-
ting system does not violate any other requirement of this 
manual. 

·  Any mounting system limitation on inclination or accesso-

ry required to maintain a specific System Fire Class Rating 
should be clearly specified in the installation instructions 
and UL2703 certification of the mounting system supplier. 

ENVIRONMENTAL CONDITIONS   

·  The module is intended for use in general open-air clima-

tes, as defined in IEC 60721-2-1: Classification of environ-
mental conditions Part 2-1: Environmental conditions ap-
pearing in nature - temperature and humidity.   

·  Please consult the Canadian Solar Inc. technical support 

department for more information on the use of modules 
in special climates, such as an altitude greater than 

   2000 m, heavy snow, severe hail storm, hurricane etc.

·  Do not install modules near open flames or flammable 

materials.  

Содержание CS3U-MB-FG

Страница 1: ...1 INSTALLATION MANUAL OF BIFACIAL MODULE For professional use only...

Страница 2: ...NTING METHODS FOR FRAMELESS BIFACIAL MODULE CLAMPING 12 6 2MOUNTING METHODS FOR FRAMELESS BIFACIAL MODULE SINGLE AXIS TRACKERS 14 6 3 MOUNTING METHODS FOR FRAMED BIFACIAL MODULE BOLTING 15 6 4 MOUNTIN...

Страница 3: ...to property in connection with handling PV modules system installation or compliance or non compliance with the instructions set forth in this manual 2 0 SAFETY PRECAUTIONS Warning Before attempting t...

Страница 4: ...e fer tility or the unborn child causes damage to organs through prolonged or repeated exposure is very toxic to aquatic life with long lasting effects may cause cancer is very toxic to aquatic life a...

Страница 5: ...V module datasheet or nameplate label An assembly together with its overcurrent device s that is listed for continuous operation at 100 percent of its rating shall be permitted to be used at 100 perce...

Страница 6: ...ding to IEC 61730 2 please refer to the datasheet or the product nameplate for the detailed types Consult your local authority for guidelines and require ments for building or structural fire safety U...

Страница 7: ...uld be safely fixed to bear all expected loads including wind and snow loads After the installation of double glass modules a maximum 40 mm deflection for frameless module and a 30 mm deflection for f...

Страница 8: ...ort circuit current Isc differ substantially from the spe cifications this indicates that there is a wiring fault Do not connect different connectors brand and model together When modules have been pr...

Страница 9: ...400 mm 280 mm 1400 mm jumper cable Modules in adjacent rows should be rotated 180 degrees for proper installation Portrait installation one row Leap frog for single axis tracker CS3U Cable length 167...

Страница 10: ...sible to use standard grounding methods for certain module ranges CORRECT CONNECTION OF PLUG CONNECTORS Make sure that all connections are safe and properly mated The PV connectors should not be subje...

Страница 11: ...e cup washer concave side up between the frame and the wire 2 Then tighten the bolt using the toothed nut GROUNDING METHOD BOLT TOOTHED NUT CUP WASHER and UL 1703 a safety factor of 1 5 should be appl...

Страница 12: ...t shadow on the cells 3 Not to damage or scratch the surface of the glass 4 To ensure the clamps overlap the module by 13 mm to 15 mm 5 To ensure the minimum clamping clearance of the clamps 4 mm 6 To...

Страница 13: ...20 mm Maximum Load Uplift load 2400 Pa Downforce load 3600 Pa Use 6 clamps on the long side Mounting rails run parallel to the long side frame Use 4 clamps on the long side Mounting rails run perpend...

Страница 14: ...0 Pa Clamp length 200 mm A 390 20 mm Maximum Load Uplift load 2400 Pa Downforce load 5400 Pa 6 2 MOUNTING METHODS FOR FRAMELESS BIFACIAL MODULE SINGLE AXIS TRACKERS These mounting methods have been qu...

Страница 15: ...Clamp A A A A A A A A Tube Clamp Rail Clamp A A A A Tube Rail A A Use 4 clamps on the long side Mounting rails run parallel to the long side frame Mounting rails fixed on torque tube Clamp length 130...

Страница 16: ...nal mounting points should be used The system designer and the in staller are responsible for calculating the load and ensu ring that the support structure meets the requirements Modules should be bol...

Страница 17: ...limit as much as possible shade on module rear side cells Canadian Solar Inc s warranty may be void in cases where improper clamps or unsuitable installation methods are found When installing inter m...

Страница 18: ...s run perpendicular to the long side fra me Clamp length 40 mm A 270 380 mm C 10 2 mm Maximum Load Uplift load 2400 Pa Downforce load 3600 Pa Clamp length 80mm A 270 380 mm Maximum Load Uplift load 36...

Страница 19: ...Mounting rails fixed on torque tube tracker Two modules share one tube portrait installation Bolting on long frame side using 400 mm 1300 mm mounting holes as shown at arrow location Mounting rails ru...

Страница 20: ...rce load 2400 Pa A A Mounting Rail Clamp Use 2 long center clamps on the long side of each module or bolting on the center holes of the long side frame Overlap length of clamp and frame 400 mm Maximum...

Страница 21: ...st mounting holes Mounting rails run parallel to the long side frame Mounting rails fixed on torque tube tracker Overlap support length of between rail and frame A 730 mm Center distance between clamp...

Страница 22: ...M6 plain washer O D 18 mm 1300 mm 400 mm holes position Drawing No SF7 MR 04 039_Drbiku 1800Pa 30mm Uplift load 1800 Pa Downforce load 1800 Pa SF7QG 1500V en revision 1 0 CS3U MB AG CS3U PB AG Soltec...

Страница 23: ...uire cleaning rain will have a self cleaning effect If the module has become soiled it shall be washed with water and a non abrasive cleaning brush or sponge du ring the cool part of the day Do not sc...

Страница 24: ...and corner protector 24 3 kg 53 6 lbs CS3K 285MB FG 285 31 9 8 94 38 7 9 57 25 CS3K 290MB FG 290 32 1 9 04 38 9 9 65 25 CS3K 295MB FG 295 32 3 9 14 39 1 9 73 25 CS3K 300MB FG 300 32 5 9 24 39 3 9 82 2...

Страница 25: ...310PB FG 310 33 1 9 37 39 7 9 81 25 CS3K 315PB FG 315 33 3 9 46 39 9 9 89 25 CS3K 320PB FG 320 33 5 9 56 40 1 9 97 25 CS3K 325PB FG 325 33 7 9 65 40 9 10 21 25 CS3U 350PB AG 350 39 2 8 94 46 6 9 51 2...

Страница 26: ...ent Imp A Open Circuit Voltage Voc V Short Circuit Current Isc A Max Series Fuse Rating A Overall Dimension mm Weight Kg CS3W 420PB AG 420 39 5 10 64 48 0 11 26 25 CS3W 425PB AG 425 39 7 10 71 48 2 11...

Страница 27: ...covers the requirements for the cleaning pro cedure of Canadian Solar Inc s photovoltaic modules The purpose of these cleaning guidelines is to provide general information for cleaning Canadian Solar...

Страница 28: ...re that brushes or agitating tools are not abrasive to glass EPDM silicone aluminum or steel Conduct the cleaning activities avoiding the hottest hours of the day in order to avoid thermal stress on t...

Отзывы: