HOME/SHOP HEATER SPECIFICATIONS
HOME/SHOP HEATER
CONFIGURATIONS
4
+
+
8 1/4”
14 1/4”
3 3/4”
26”
8 3/4”
24”
31
1
/
2”
Exhaust
Air Inlet
MINIMUM
CLEARANCES TO
COMBUSTIBLES
1” from BACK of stove
to combustibles
10” from SIDE of stove to
combustibles
1” from BACK CORNER
of stove to
combustibles
16” from TOP of stove
to combustibles
3” from PL VENT to
combustibles
6” non-combustible
surface in FRONT
of stove
36” to drapes, doors,
anything that can
swing
120 CORN HEATER
STOVE PLACEMENT
The stove must be placed so that no combustibles are within, or can swing within (ie. drapes, doors) 36” of the
stove itself.
FLOOR PROTECTION
The stove must be installed on a non-combustible floor protector (ie. sheet steel with cement, tile, slate)
extending the full width and depth of the stove and extending 6” in front of the stove. The floor protector
needs to be a minimum 24.5” deep x 30.5” wide and must be a minimum 0.018” thick (26 gauge).
Floor protection must extend under and 2” to each side of a chimney tee (if used).
If the stove is placed in a location where the ceiling height is less than 7’, it must follow the requirements in the
ALCOVE INSTALLATION section.
The stove & floor protection must be installed on a level, secure floor.