Disconnect the power cord before performing any maintenance. IMPORTANT: Touching the OFF
button on the control board does NOT disconnect power to the stove.
DO NOT THROW YOUR INSTRUCTIONAL GUIDE AWAY. This guide have important operating &
maintenance information that you will need at a later time.
Do not place clothing or other flammable items on or near the stove. Because this stove can be
controlled by a thermostat, there is a possibility of it starting and igniting any items placed on or
near it.
This appliance must be connected to a standard 110 - 120V, 60 Hz grounded electrical outlet. Do
NOT use an adapter plug or sever the ground plug. Do NOT route the electrical cord underneath,
in front of or over the appliance.
It is highly recommended to connect the stove to a standard 110 120V ground surge protected
unit or surge protected outlet.
When installed in a mobile home, the heater must be bolted to the floor, have outside air, and
MUST NOT BE INSTALLED IN THE BEDROOM (per H.U.D. requirements). Check with local building
officials.
Educate all children on the dangers of a high temperature stove.
Young children should be supervised when they are in the same room as the stove.
NEVER PUT YOUR FINGERS NEAR THE AUGER. Pellet fuel is fed to the burn grate by a screw auger
that is driven by a high torque motor. The auger can start and stop automatically anytime while
the stove is operating.
Do NOT connect this appliance directly to air ducts or any air distribution system. This will void any
warranty.
Do NOT burn with insufficient combustion air. A periodic check is recommended to ensure proper
combustion air is admitted to the combustion chamber. Setting the proper combustion air is
achieved by adjusting the slide damper rod located on the side of the appliance.
It is advisable to clean the exhaust vent bi-annually or every two tons of corn burned.
Soot or creasote may accumulate when the stove is operated under incorrect conditions such as
an extremely rich burn (black tipped, lazy orange flames).
Do NOT use insulated or plastic pipes when installing your venting. Make sure to allow at least 24
hours for all joints to seal properly or the seal will expand and allow smoke to vent into the room.
PLEASE NOTE: Dansons Group Inc. and Canadian Comfort Industries grant no warranty, implied or
stated, for the installation or maintenance of your stove and assume no responsibility for any
consequential damage(s).
SAFETY
PRECAUTIONS
13