background image

Disconnect the power cord before performing any maintenance.  IMPORTANT: Touching the OFF
button on the control board does NOT disconnect power to the stove.

DO NOT THROW YOUR INSTRUCTIONAL GUIDE AWAY.  This guide have important operating &
maintenance information that you will need at a later time.

Do not place clothing or other flammable items on or near the stove.  Because this stove can be
controlled by a thermostat, there is a possibility of it starting and igniting any items placed on or
near it.

This appliance must be connected to a standard 110 - 120V, 60 Hz grounded electrical outlet.  Do
NOT use an adapter plug or sever the ground plug.  Do NOT route the electrical cord underneath,
in front of or over the appliance.

It is highly recommended to connect the stove to a standard 110 120V ground surge protected
unit or surge protected outlet.

When installed in a mobile home, the heater must be bolted to the floor, have outside air, and
MUST NOT BE INSTALLED IN THE BEDROOM (per H.U.D. requirements).  Check with local building
officials.

Educate all children on the dangers of a high temperature stove.

Young children should be supervised when they are in the same room as the stove.

NEVER PUT YOUR FINGERS NEAR THE AUGER.  Pellet fuel is fed to the burn grate by a screw auger
that is driven by a high torque motor.  The auger can start and stop automatically anytime while
the stove is operating.

Do NOT connect this appliance directly to air ducts or any air distribution system.  This will void any
warranty.

Do NOT burn with insufficient combustion air.  A periodic check is recommended to ensure proper
combustion air is admitted to the combustion chamber.  Setting the proper combustion air is
achieved by adjusting the slide damper rod located on the side of the appliance.

It is advisable to clean the exhaust vent bi-annually or every two tons of corn burned.

Soot or creasote may accumulate when the stove is operated under incorrect conditions such as
an extremely rich burn (black tipped, lazy orange flames).

Do NOT use insulated or plastic pipes when installing your venting.  Make sure to allow at least 24
hours for all joints to seal properly or the seal will expand and allow smoke to vent into the room.

PLEASE NOTE:  Dansons Group Inc. and Canadian Comfort Industries grant no warranty, implied or
stated, for the installation or maintenance of your stove and assume no responsibility for any
consequential damage(s).

SAFETY

PRECAUTIONS

13

Содержание Corn Stove

Страница 1: ... IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH For the following models CC2 CC3 CCGB2 CCGB3 Installations shall conform to CAN CSA B365 Installation Code For Solid Fuel Burning Appliances and Equipment in Canada and NFPA 211 Chimney Fireplaces Vents and Solid Fuel Burning Appliances in the USA Manufactured by Marketed by CORN BURNING SHOP GARAGE HEATERS ...

Страница 2: ...t for the safety of your family as well as efficient satisfactory operation Initial setup of the stove is the most important step to ensure consistent comfortable operation Know the quality and characteristics of the corn you burn Corn can vary greatly from company to company from load to load and even from bag to bag BE DILIGENT IN YOUR CLEANING PROGRAM Remember that most operational dilemmas wit...

Страница 3: ...e metal pipe ONLY either solid or flexible PVC or any other non metallic material MUST NOT BE USED For more information regarding corn stove operations or other specifications please read the OPERATIONS GUIDE section of this manual Updated guides are available online at www dansons com support Have your local Dealer demonstrate all operational cleaning maintenance steps necessary for your stove In...

Страница 4: ...hat no combustibles are within or can swing within ie drapes doors 36 of the stove itself FLOOR PROTECTION The stove must be installed on a non combustible floor protector ie sheet steel with cement tile slate extending the full width and depth of the stove and extending 6 in front of the stove The floor protector needs to be a minimum 24 5 deep x 30 5 wide and must be a minimum 0 018 thick 26 gau...

Страница 5: ...ore placing the stove connect the elbow or TEE and measure off the 3 clearance Minimum clearances to combustibles Due to radiant heat from the side panels home shop heaters require more space for placement ALCOVE DIRECT THROUGH THE WALL 1 10 18 6 3 6 10 1 1 from the back 16 from the top 10 from the sides CLEARANCES DIRECT VENT INSTALLATION INTERIOR VERTICAL 45 CORNER THROUGH WALL o 45 CORNER INTER...

Страница 6: ...umber 8 gauge copper wire or equivalent The stove must have a permanent outside air source with a 1 4 inch screen over the inlet When moving your mobile home all exterior venting MUST BE REMOVED while the mobile home is being relocated Upon completion of relocation all venting must be reinstalled and securely fastened PL or L vent must be 3 or 4 and must extend a minimum of 36 inches above the roo...

Страница 7: ...e the vent diameter to 3 or larger C C A A B B Outside air is HIGHLY RECOMMENDED for all other installations When outside air is taken from an existing chimney the exhaust system MUST NOT terminate in the same chimney The outside air pipe on your stove is 2 O D The outside air connecting pipe must be at least 2 I D The outside air connecting pipe must be as short and as free of elbows as possible ...

Страница 8: ... SHORT AS POSSIBLE especially on horizontal installations o o o o Horizontal sections must have a 1 4 rise every 12 of travel after 3 feet Corn vent connections must be sealed with high temperature RTV silicone and or screwed together with a least 3 x 3 8 long stainless steel screws Seal each vent section by injecting a liberal amount of this silicone into the gap Use 4 diameter venting if vent or...

Страница 9: ...O SINGLE FAMILY DWELLINGS AND SERVES BOTH DWELLINGS I Minimum 3 foot clearance from any forced air intake of any other appliance J Minimum 4 foot clearance from a non mechanical air supply inlet to the building or the combustion air inlet to any other appliance K Minimum 2 foot clearance below eaves or overhang 3 10 2 A O G F K L D C B B E P N H M F J I L Minimum 1 foot clearance to an outside cor...

Страница 10: ...ght the pellets and close the door part way until the pellets are burning briskly 7 to 9 minutes 4 Close and latch the door securely and restart the system to feed fuel turn the auger switch on if applicable 5 Turn the fuel feed to 3 setting for at least 30 minutes This is necessary to build up an adequate bed of coals to maintain combustion at lower feed settings NOTE You may need to experiment w...

Страница 11: ...mer COUNTER CLOCKWISE To DECREASE fuel feed rate turn the trimmer CLOCKWISE Once the damper rod is set and your corn is burning steadily ie no popcorning you are ready to fine tune your stove Fine tuning is required due to the differences in installation configuration geography insulation of the home and quality of corn First switch to feed rate 1 by pressing the START FEED RATE button until the 1...

Страница 12: ...st system works with negative combustion chamber pressure and a slightly positive chimney pressure Therefore the exhaust system MUST BE COMPLETELY AIR TIGHT and properly installed All pellet joints must be sealed with HI TEMP RTV SILICONE SEALANT and at least 3 sheet metal screws to each other as well as to the stove This unit must be properly installed to prevent the possibility of a house fire T...

Страница 13: ...ld be supervised when they are in the same room as the stove NEVER PUT YOUR FINGERS NEAR THE AUGER Pellet fuel is fed to the burn grate by a screw auger that is driven by a high torque motor The auger can start and stop automatically anytime while the stove is operating Do NOT connect this appliance directly to air ducts or any air distribution system This will void any warranty Do NOT burn with i...

Страница 14: ...HESE WARRANTIES WILL NOT APPLY if abuse accident improper installation negligence or use beyond rated capacity causes damage HOW TO MAKE A CLAIM Any claim under this warranty should be made to the dealer from whom this appliance was purchased Then contact is made with the manufacturer giving the model and serial numbers the date of purchase your dealer s name and address plus a simple explanation ...

Страница 15: ...__ City _______________________________________________ State Province __________________________________ Zip ________________________________ Telephone _______________________________________________________ UNIT INFORMATION Model Number ___________________________________ Purchase Date _____________________________________ Serial Number ____________________________________ Purchase Price _______...

Страница 16: ...trieval system in any form or by any means without the expressed written permission of Canadian Comfort Industries 26319 Twp Rd 531 Acheson AB Canada T7X 5A3 1 877 303 3134 To register your purchase visit www dansons com support My local Dansons dealer is Technical Support Monday to Friday 9 am to 8 pm EST Saturday 11 am to 7 pm EST 1 866 456 9269 ...

Отзывы: