Subsection 02 (WIRING HARNESS AND CONNECTORS)
529036175
1. Remove rear protector from connector.
2. Pull out the connector lock.
smr2009-045-025_a
3. Insert tool to unlock terminal.
smr2009-045-026_a
1. Unlock here
4. Gently pull on the wire to extract the terminal
out the back of the connector.
smr2009-045-027_a
NOTICE
Before installing wire terminals in
the connector, ensure all terminals are prop-
erly crimped on wires. After installation of
wire terminals in the connectors, ensure they
are properly locked by gently pulling on them
as if to extract them.
FURUKAWA CONNECTOR
Furukawa Connector Application
Voltage regulator/rectifier.
Terminal Removal
1. Remove the secondary lock (plastic insert).
smr2010-050-021_a
Step 1: Remove the secondary lock
2. Carefully insert the
GM TERMINAL EXTRACTOR
(P/N 12094430)
between the lock and the pin to
release the pin.
smr2010-052-003
GM TERMINAL EXTRACTOR (P/N 12094430)
vmr2016-133
13