39
Outdoor Sensor connected to Slave boiler 2 (DRH ONLY)
Description
Electrical Connection(s)
Programming Instructions
•
Slave boiler outdoor sensor
configuration
•
When done correctly, the
outdoor temperature will be
shown on the Master boiler
Slave Boiler
1)
Press
and
2)
Press
[Sensor Configuration]
3)
Select
S5 (J8-11) Sensor
4)
Connector Type:
10K NTC Single Non-Safety
5)
The control will proceed into a Lockout 2 condition
6)
Press
[Verify]
>
[Begin]
>
[Yes]
7)
Press the reset button on the ignition control within the alotted time
Master Boiler
8)
Press
and
9)
Press
[Lead Lag Master Configuration]
10)
Press
[Advanced Settings >]
11)
Press the to arrive at
Outdoor Reset
12)
Select
Enable: Enabled
13)
Select
Maximum outdoor temperature
(WWSD)
14)
Select
Minimum outdoor temperature
(Outdoor Design)
15)
Select
Low Water Temperature
(Min. Water Temp)
16)
Select
Outdoor boost maximum off point
(Design Max.)
Содержание DFH/W500
Страница 2: ......
Страница 40: ...35...
Страница 71: ...66 PART 12 EXPLODED VIEW...
Страница 72: ...67 3 44 10 45 46 47 28 31 26 52 57 58 59 54 60 61 SOLA Control Panel 39 4...
Страница 82: ...77 PART 13 ELECTRICAL DIAGRAMS...
Страница 83: ...78...
Страница 85: ...80...
Страница 86: ...81...
Страница 87: ...82...