Camtek CAM1095 Скачать руководство пользователя страница 8

8

Inspection Camera Kit 22mm

CAM1095

Performing a Pipe Inspection 

Inspecting a pipe is done by pushing the camera 

into the pipeline gradually while observing the 

monitor.

•  When pushing, the end of your stroke should be 

as close to the entry as possible. Standing too 

far back (with an excess of cable between your 

hands and the entry) may cause the cable to fold 

on itself outside the entry and damage the cable.

•  Folding the pushrod on the sharp edge of an 

entry can cause it to snap. Caution must be used 

to avoid bending the pushrod on sharp corners. 

This can cause pushrod failure. 

•  If the camera just does not seem to want to go 

any farther, do not force the camera. Try anoth-

er entry-point if one is available. Or, try running 

water down the line.

The system can travel through multiple 45 and 

90-degree bends. Do not, however, try to force it 

through a P-trap or Tee if there is a large amount 

of resistance.

Using the Meter Counter

•  Press either meters or feet for correct display 

measurement

Resetting the Meter Counter Zero-Point

•  You can also reset this system zero point at any 

time with a press on the Zero Key. It is good 

practice to do this, for example, at the entrance 

to a pipe.

Retrieving the Camera

•  Once the inspection has been completed, pull 

the pushrod back with slow, steady force. 

•  Continue running water down the line if possible, 

to help clean the pushrod. A towel can be used to 

wipe off the pushrod as it is withdrawn. 

•  Pay attention to the force required to withdraw 

the pushrod. The pushrod and camera may get 

hung up while being retrieved and may need to 

be manipulated as done during insertion. 

•  Do not force the pushrod or exert excessive 

force. This could damage the camera or push-

rod. 

•  When pulling the pushrod, keep clear of any 

sharp edges and do not pull at sharp angles to 

the inlet to prevent damage to the pushrod jacket.

Spring Assembly

•  The spring assembly is the area where foreign 

matter is most likely to accumulate. 

•  Within the spring is the splice between the push-

rod and a connector. Should sharp objects or 

harsh chemicals be allowed to remain in this 

area for long periods, they may wear on these 

components. 

•  Stretch the spring end-to-end as far as the inter-

nal safety cables allow to check this area.

Meter Counter Function

Camtek Inspection System in Use

WARNING

WARNING

Содержание CAM1095

Страница 1: ...OPERATOR S MANUAL Please read these instructions completely before operating this system Inspection Camera Kit 22mm Inspection Camera Kit 22mm CAM1095...

Страница 2: ..._______________________________________________ 8 Spring Assembly_______________________________________________________ 8 Removing Camera Head from the Reel_____________________________________ 9 Han...

Страница 3: ...erating equipment Do not use equipment while you are tired or under the influence of drugs alcohol or medication Use personal protective equipment Always wear eye protection gloves while operating Ele...

Страница 4: ...act with corrosive drain cleaners Drain cleaning chemicals can cause serious burns as well as damage the cable Neutralize or remove corro sive drain cleaners in the drain before starting the job Prote...

Страница 5: ...control SYSTEM COMPONENTS Inspection Camera Kit 22mm includes The Camera Head the Cable Reel and Frame and the Monitor Control Unit Cable Reel The pushrod is housed in a handheld metal drum which is l...

Страница 6: ...the charged battery plug the power output cord of the battery to the DC 12V Input Jack of the Monitor then press the button on the battery Monitor Control Unit Recorder Be sure you are familiar with...

Страница 7: ...see an image on the monitor check to make sure its power is turned ON Video 1 on the monitor is live view mode Video 2 on the monitor is the DVR digital video re corder mode Note Don t misuse the pow...

Страница 8: ...his system zero point at any time with a press on the Zero Key It is good practice to do this for example at the entrance to a pipe Retrieving the Camera Once the inspection has been completed pull th...

Страница 9: ...ns to the pipe When inspecting a pipe it is usually necessary to give a little extra push in the bends Back the camera head approximately 7 from the bend if necessary and give it a quick push pop ping...

Страница 10: ...USB micro SD device has error 6 IR It blinks when the remote control is in use for Recording Video 7 The recorded video files will be found in a di rectory of USB devices 8 You can use the on screen...

Страница 11: ...cket on the wall and insert the other end into the DC Jack on the battery box The battery can be charged while the battery box is on and the device is being used Howev er once the power in the battery...

Страница 12: ...contact the Camtek service department Picture BUT No Lights Check if Main Power switch is ON and in cor rect position Check to see if the LIGHT power switch is ON and intensity control is turned up C...

Страница 13: ...e and contact Camtek service department Please note USB Drives might need to be for matted on a computers prior to use please fol lowing the instruction on how to do this below Plug USB into Computer...

Страница 14: ...repaid and you will be compensated for these charges if it is determined that the part is defective If repairs are necessary due to conditions beyond our control or if the item is out of warranty we w...

Страница 15: ...15 Inspection Camera Kit 22mm CAM1095 Notes...

Страница 16: ...08 8122 0469 sales camtek net au www camtek net au...

Отзывы: