Inspection Camera Kit 22mm
CAM1095
Performing a Pipe Inspection
Inspecting a pipe is done by pushing the camera
into the pipeline gradually while observing the
monitor.
• When pushing, the end of your stroke should be
as close to the entry as possible. Standing too
far back (with an excess of cable between your
hands and the entry) may cause the cable to fold
on itself outside the entry and damage the cable.
• Folding the pushrod on the sharp edge of an
entry can cause it to snap. Caution must be used
to avoid bending the pushrod on sharp corners.
This can cause pushrod failure.
• If the camera just does not seem to want to go
any farther, do not force the camera. Try anoth-
er entry-point if one is available. Or, try running
water down the line.
The system can travel through multiple 45 and
90-degree bends. Do not, however, try to force it
through a P-trap or Tee if there is a large amount
of resistance.
Using the Meter Counter
• Press either meters or feet for correct display
measurement
Resetting the Meter Counter Zero-Point
• You can also reset this system zero point at any
time with a press on the Zero Key. It is good
practice to do this, for example, at the entrance
to a pipe.
Retrieving the Camera
• Once the inspection has been completed, pull
the pushrod back with slow, steady force.
• Continue running water down the line if possible,
to help clean the pushrod. A towel can be used to
wipe off the pushrod as it is withdrawn.
• Pay attention to the force required to withdraw
the pushrod. The pushrod and camera may get
hung up while being retrieved and may need to
be manipulated as done during insertion.
• Do not force the pushrod or exert excessive
force. This could damage the camera or push-
rod.
• When pulling the pushrod, keep clear of any
sharp edges and do not pull at sharp angles to
the inlet to prevent damage to the pushrod jacket.
Spring Assembly
• The spring assembly is the area where foreign
matter is most likely to accumulate.
• Within the spring is the splice between the push-
rod and a connector. Should sharp objects or
harsh chemicals be allowed to remain in this
area for long periods, they may wear on these
components.
• Stretch the spring end-to-end as far as the inter-
nal safety cables allow to check this area.
Meter Counter Function
Camtek Inspection System in Use
WARNING
WARNING