background image

6.9. StandBy mode

A) Turning off the power of the IP camera head (Camera Standby function):

1a.

 Through www: Log in to the LTE communication module e.g. 

http://100.100.100.100:83/

 Go

to 

Services > Inputs 

/

 Outputs > Output > ON / OFF

. We turn on "Camera Standby Mode", the 

camera will be turned off. Turn on the camera in the same way as turn it off.

1b. 

Through SMS: Send an SMS containing "<password> camera_off" or "<password> 

camera_on" to the SIM card number. In the <password> enter your password, e.g. "camsat ca-
mera_off" or "camsat camera_on".

2. 

The active standby status is shown in the 

Services >> Inputs 

Outputs >> Status 

tab.

B) IP camera head off by default after starting the system:

The Camera Standby function can be turned on by changing the settings

Services > Inputs 

Outputs > Output > Configuration 

of the output in the active state, set the 

‘Camera Standby’ output to ‘off’.

Page 29

Содержание iCAM-Mobile HD II

Страница 1: ...Rapid deployment camera system with wireless system for city monitoring www camsat com ...

Страница 2: ...ency of the device The contents of this manual comprise proprietary information of CAMSAT and are intended only for use by purchasers of the equipment described herein In order to copy or use any part of this manual for purposes other than the application or maintenance of the described equipment it is required that the customer should first obtain a written consent from CAMSAT ...

Страница 3: ... Installation at destination monitored place 3 6 Launch at destination monitored place 3 7 Memory replacement A HDD removal B HDD installation 3 8 Working mode of heater and thermostat 3 9 Description of the inner panel 4 Factory settings and reset 18 4 1 Radioline 4 2 Recorder 5 Remote access to the iCAM Mobile HD system 20 5 1 Remote access to the system 5 2 Access to the iCAM Mobile HD system u...

Страница 4: ...recorder A TCP IP configuration IP address settings B Connection with an IP camera C Formatting and configuring memory storage D Recording schedule E Calculating storage capacity 7 3 Using the recorder A Preview video streams B Playing the records C Archiving the records D Playing downloaded video content 7 4 Configuration of mobile applications to operate the recorder 8 Recommendations 38 8 1 Act...

Страница 5: ...st care for the safety of its installers and users For safety reasons observe all the guidelines in this manual and peripheral devices manuals such as the PC or IP camera Before installing the device carefully read the entire instruction manual Ensure safe working conditions The user s own modifications of the device will prevent its legal use and render the warranty null and void The device has p...

Страница 6: ...fter disconnecting its power supply cables and the cables between it and other devices if the device is transferred to a room where the temperature is higher than where it has previously been kept water vapour may condensate inside its casing which will prevent its proper use Wait until the condensed water evaporates 1 4 Distances and interferences The transmission distance may vary depending on t...

Страница 7: ...ill be available from anywhere in the country 2 2 Package content iCAM MobileHD system that contains 2MPX PTZ IP Camera Battery iCAM AKU 12 14 8V 21 2Ah Li ion 4G LTE module RadioLink 5 6Ghz module Recorder module 1 TB HDD Quick connector mounting socket mounting accessories LTE Antenna x2pcs 5 Ghz Antenna x2pcs Key User Manual and CE Declaration 2 3 Specification Product specification Resolution ...

Страница 8: ...tach the camera to the holder on the front cover of the device The entire cable coming out of the camera must be in the camera holder do not place it in the case IP Camera factory settings Standard Onvif IP address 192 168 1 108 Onvif port 80 Username admin Password admin In order to extend the device s operating time on the battery you can turn off the heater in the camera if it has one The confi...

Страница 9: ...The device can be powered from an alternative DC power source e g external 12 24V battery electric installation of car 12V or 24V other 12 24V installation The power source must have a minimum capacity of 40W e g 3 5A 12V or 2 2A 24V WARNING When iCAM Mobile works in this configuration the internal battery will not be charged In the indicated place connect the 12 24V DC power sup ply according to ...

Страница 10: ... ready for use it must not be formed It is approxi mately 60 75 charged The battery is charged only with 230V power supply the charger module additionally charges up to 120W max 160W together with the camera When the device is not used for a longer period of time over 4 months store the batte ry at 60 75 charged storage of a battery charged at another rate may shorten its li fetime The battery sho...

Страница 11: ...ored place The set iCAM Mobile with an IP camera should be mounted only to solid stable wall and mast structures The installer is responsible for the correct installation of the came ra Items that should be mounted in the selected place Bracket adapter with wall anchors for wall mounting Bracket adapter with steel straps for pole mounting WARNING The handle should be mounted vertically the place f...

Страница 12: ... The time it takes to start the device at low temperatures can be extended by several minutes This is caused by the heater and thermostat The device is ready when the green LED STATUS NVR lights up After turning the key in the ignition switch to the I position in the version with remote control you should additionally press the ON button on the remote control near the devi ce two light on the exte...

Страница 13: ...using SSDs such drives have a limited amount of data overwriting iCAM Mobile has a heater with a thermostat therefore it is not necessary to use disks adapted to work in freezing temperatures A HDD removal We exchange the memory only when the device is turned off and the ignition switch is in the 0 position Start with loosening the two M3 screws then slide the drive up You can now disconnect the S...

Страница 14: ...he iCAM Mobile cover and tighten the screws After connecting a new disk format it The process is covered by this manual later 3 8 Working mode of heater and thermostat iCAM Mobile is adapted to work also in freezing temperatures up to 20 C thanks to the HDD heating system Controlling this system is possible through jumpers inside the device Page 14 ...

Страница 15: ...ain the minimum HDD temperature and the temperature will de pend on the outdoor temperature Regardless of the temperature and method of power supply in this mode the recorder will be started no later than after 1 minute Setting the device in this mode may extend the battery life c Intermediate mode I not recommended is set when pins 1 with 2 and 4 with 5 are combined Description In this mode the s...

Страница 16: ...3 9 Description of the inner panel Page 16 ...

Страница 17: ...Page 17 ...

Страница 18: ...IDR 24 DHCP Server Disabled User name camsat User password camsat To restart the device to the factory settings log in to the radio module then in the ADVANCED SETTINGS Backup Restore menu click the Factory Default button or hold the reset button for 5 seconds which is available on the main panel The DHCP server must be enabled for the wireless connection to mobile devices to be automatically conf...

Страница 19: ...rt for CMS app 5050 Port for mobile devices 5053 User name admin User password Pre configured IP camera Standard Onvif IP address 192 168 1 108 Onvif port 80 User admin Password admin To restart the device to the default settings log in to the recorder module then in the Configuration System Restore menu click the Restore button Page 19 ...

Страница 20: ...f the device did not obtain the IP address automatically you must manually enter the static unique IP address default gateway and subnet mask in advanced options when connecting The DHCP server must be enabled for automatic device configuration CAMERA CONNECTION SETTINGS Network Settings 5 3 Access to the system through the wire The device can be connected to the network using the RJ45 socket in t...

Страница 21: ...ddress from your network e g If your recorder has the address 192 168 1 50 IP came ra 192 168 1 51 then enter another free address e g 192 168 1 52 The IP ad dress must be on the same subnet as the computer Subnet Mask Usually 255 255 255 0 The subnet mask should be identical throughout the local network Default Gateway Entering the gateway IP address is ne cessary only if the device will also wor...

Страница 22: ...on method WPA2 PSK recommended and en ter your own key used to connect to the ne twork The longer and more complex the password is the better the network will be protected against unauthorized access WAN Connection Type To ensure trouble free communication between all system modules select the Stan dard Bridge operating mode After saving the wireless network settings the device may automatically r...

Страница 23: ...the SIM1 and SIM2 card slots Aftern inserting the SIM card reattach the camera and tighten the screws 6 2 Configuring the device Start the iCAM MobileHD system by turning the key in the ignition Connect to the mo bile camera by connecting to a wireless network default SSID CAMSAT password camsat com Go to 192 168 1 1 on your computer and then log in by entering your login and pas sword Login admin...

Страница 24: ...ows R cmd ping 100 100 100 100 t If the module responds to queries we can proceed to the next step WARNING If the APN access point name is incorrect we will use the private IP address instead of the public one Internet access still exists but with an undesirable IP address If the IP address is different or no connection is established check the configuration settings in the Network Modem menu Ente...

Страница 25: ...ed the correct gateway the router s IP address by default 192 168 1 1 6 5 Ports forwarding Go to the Network Firewall menu and then select the Port Forwarding tab Below the table with redirected ports is the interface for adding new entries After adding all redirection rules save the settings by clicking Apply The default port forwarding configuration Name Protocol External port Internal IP addres...

Страница 26: ...word e g camsat gps The device will send an SMS with GPS location coordinates sending an SMS may incur a fee by the operator It is possible to register events when the device leaves or returns to the geolocation zone Events can be reported in an SMS or email The zone should be enabled and selec ted in the Services GPS GPS Geofencing menu The location can be entered manual ly or automatically get t...

Страница 27: ...ion However if there is an authorization method you must enter Password or Serial Number in a text messa ge The authorization key must precede the text of the SMS command and be separated by a space For example if the selected authorization method is password and the pas sword is camsat the whole message should look like camsat reboot The same ap plies to the Serial Number which appears in the Sta...

Страница 28: ...notification rules in the form presented below By default sample rules have been introduced that require enabling and entering the message recipient The rules regarding analog voltage apply to the battery status of the iCAM MobileHD sys tem inform you about the full charge and extreme discharge Camera alarm rules notify you when an alarm is triggered in the camera e g motion detection within the c...

Страница 29: ...it off 1b Through SMS Send an SMS containing password camera_off or password camera_on to the SIM card number In the password enter your password e g camsat ca mera_off or camsat camera_on 2 The active standby status is shown in the Services Inputs Outputs Status tab B IP camera head off by default after starting the system The Camera Standby function can be turned on by changing the settings Serv...

Страница 30: ...using a browser other than Internet Explorer select Non ActiveX mode Install ActiveX plugin Internet Explorer only Run the ActiveX plugin installer rtspvideoplugin exe and close the IE browser before installation After successfully installing reopen the browser Enter the RECORDER IP address and then log in When the message appears allow the browser to run the plug in Installing Adobe Flash Player ...

Страница 31: ...he changes are confirmed with the Save button B Connection with an IP camera The camera can be connected to the recorder module in two ways by modifying the IP camera settings to the default settings of the recorder or by modifying the configuration of the recorder itself Before changing settings make sure that the camera s IP address is in the same subnet as the recorder module and computer OPTIO...

Страница 32: ...onnection with the camera C Formatting and configuring memory storage You can check the status of the memory storage connected to the recorder in the Config System HDD Just after installing the new storage medium please format it WARNING Formatting a storage media erases all data from it Select a newly connected storage from the list and then click Format After properly done formatting the device ...

Страница 33: ...te of the video stream Bitrate is the amount of information that the camera sends to the recorder depends on resolution frame rate and image quality Bitrate configuration is set in the camera settings The bit rate can be variable VBR or fixed CBR The current instantaneous flow rate can be checked in the menu Config System Stream Info Formulas for calculating the recording length for one camera MB ...

Страница 34: ...as To start the live view click one of the following icons Icon Function Run all main streams Run all extra streams Run one main stream Run one extra stream Disabled local recording on the PC IE only Enabled local recording on the PC IE only WARNING You must have a compatible camera available for PTZ functions to work properly Available PTZ options depend on the IP camera used We recommend configu...

Страница 35: ...he list on the left by checking the tick next to their name and then indicate the date of the day on which the video will be loaded The following buttons are used to control playback Ikona Funkcja Play Pause Stop Decrease recording speed Increase recording speed Save displayed view as image Internet Explorer only Archive the material to a computer disk Internet Explorer only Move to the another vi...

Страница 36: ...l be saved indicate the time range and indicate the location for saving video files The download starts by clicking the start button D Playing downloaded video content The content can be played using any application or software for watching AVI movies The recommended application for playing movies in AVI format is VLC Materials in the I8 format can be played through the interface of the recorder m...

Страница 37: ...ng the QR code or providing the IP address of the recorder module port and user data in the application Goolink P2P connection After starting the application click the button to add a new device You must enter the device serial number in three ways by scanning the QR code rewriting the UID se rial number manually or automatically searching for the device in the LAN Then enter the username and pass...

Страница 38: ... to avoid completely discharging the battery The lithium ion battery should be charged as soon as possible after discharging However if it is not used for a longer period it should be discharged to about 60 75 In this condition the battery has a significantly higher service life If the battery is stored in a completely discharged state it may be damaged The device should be stored in a cold place ...

Страница 39: ...een devices for example devices can not be seen the modules must be reset and the configuration must be carried out from the beginning For a description of resetting the modules to factory settings see section 4 Factory settings and reset B Time on recordings is incorrect If during the playback of the recordings the date or time of the recording does not match the recording the recorder s system t...

Страница 40: ...carried out in the shortest possible amount of time not exceeding 14 days counting from the moment of accepting the device for servicing If parts need to be imported the repair deadline may be extended After the repairs have been carried out the warranty period will be extended by the repair time 6 The warrantor is not responsile for the loss of the device configuration settngs resulting from devi...

Страница 41: ...9 2 Storage of waste and battery Information for users about disposing of electrical and electronic devices and batteries applies to households Page 41 ...

Страница 42: ...9 3 Declaration of Conformity Page 42 ...

Страница 43: ...Page 43 ...

Страница 44: ...e 5 GHz band The frequency range can be adjusted using the settings in accordance with legal regulations in every country It is your responsibility to be adequate settings of the complying with the applicable laws in the country or region Producer CAMSAT Gralak Przemysław Ogrodowa 2a 86 050 Solec Kujawski Poland Offer and information www camsat cctv com Sales camsat camsat com 48 52 387 10 97 ext ...

Отзывы: