Circulating fan does not shut off
✓
The Fan Override switch is in the ON
position. (Turn it to the OFF position)
✓
Defective 110
º
F fan disc
✓
Defective fan relay
✓
Defective temperature controller
25
Fan 0veride Switch
➢
First, ensure that the ambient temperature at the
110
º
F
fan disc is less than 80
º
F.