5
GB
Rate: 9.1 g/h (0.125 kW)
Category: butane direct pressure
Thank you for choosing the Campingaz
®
Ambiance
Lantern
.
A - IMPORTANT: ALWAYS BE CAREFUL
WHEN USING GAS !
The purpose of these instructions is to enable you
to use your Campingaz
®
Ambiance Lantern
cor-
rectly and in complete safety.
Please read them carefully to familiarise yourself
with the equipment prior to assembling the gas
container.
Please observe these instructions and the safety
measures printed on the Campingaz
®
CV 300 PLUS
cartridges. Failure to observe these instructions
may result in the user and people in the immediate
vicinity being put at risk.
Keep these instructions in a safe place so that you
can refer to them if needed.
This equipment must be used exclusively with
Campingaz
®
CV 300 PLUS cartridges. Using other
gas containers may be dangerous.
The Société Application Des Gaz (Gas
Enforcement Company) accepts no responsibility
where cartridges of any other make are used.
This equipment must only be used in adequately
ventilated areas (minimum 2 m
3
/h/kW) and at a
good distance from any flammable material.
Do not use equipment which leaks, functions
incorrectly or is damaged. Return it to your retailer
who will inform you of your nearest after-sales ser-
vice.
Never modify this equipment or use it for purposes
for which it is not intended.
Do not use this product in caravans, cars, tents,
huts, sheds or any small enclosed areas.
The product should not be used while sleeping or
left unattended.
This product consumes fuel through combustion
or consumption of oxygen and gives off certain
substances and gas, which could be dangerous
such as carbon monoxide (CO).
Carbon monoxide is an odorless, clear gas that
can cause flu-like symptoms, sickness, illness,
and possibly death if produced inside aforesaid
enclosed areas through use of the product without
proper ventilation.
B - PUTTING INTO OPERATION
INSTALLING THE CAMPINGAZ
®
CV 300 PLUS
CARTRIDGE
(Where the existing cartridge is empty, read paragraph
D : "Removing the cartridge")
When installing or changing a cartridge, always opera-
te in a very well-ventilated location, preferably outside,
never near a flame, heat source or spark (cigarette,
electric apparatus, etc.) and far away from other peo-
ple and inflammable materials.
AS CAMPINGAZ
®
CV 300 PLUS
CARTRIDGES ARE
VALVE-OPERATED, THEY CAN BE DETACHED
FROM THE EQUIPMENT, EASILY TRANSPORTED
(EVEN WHEN NOT EMPTY) AND FITTED TO OTHER
CAMPINGAZ
®
EQUIPMENT IN THE
300 PLUS
RANGE DESIGNED TO OPERATE EXCLUSIVELY
WITH THESE CARTRIDGES.
a) Check that the gas supply is fully turned off by turning
the control wheel (1) clockwise as far as the handle
("-" direction of the arrow) (fig. 5).
b) Put the textile cover (7) on the cartridge (depending
on the model) (fig. 2).
c) Hold the stove (
caution
- it may be hot!) and gently
screw the cartridge (4) onto the stove clockwise until
you hear a click (about one sixth of a turn) (fig. 2). Do
not tighten the cartridge further, as you may damage
its valve.
d) Place the stabiliser (3) underneath the cartridge (fig. 2).
If there is a leak (smell of gas), put the lamp outside
immediately, in a well ventilated area, without heat sour-
ce, where the leak can be traced and stopped. If you
wish to check that your lamp is not leaking, do so outsi-
de. Never trace leaks using a flame, use a gas leak
solution.
The lamp is now ready to operate.
C - USE
1) Additional instructions:
Do not use your lamp at a distance closer than 20
cm to a wall or flammable object, nor closer than
40 cm to a ceiling (distance from the top of the
glass).
Place the lamp on a horizontal surface.
Avoid making any sudden movements with the
lamp, to prevent large flames appearing, caused by
the combustion of liquid butane instead of vapori-
sed butane. If this occurs, extinguish the lamp by
closing the tap.
If there is a leak (i.e. you can smell gas), close the tap.
When in use (or immediately after it is turned off),
the heat given off by the burner makes some parts
of the lamp extremely hot (including the glass and
the perfume diffuser).
It is dangerous to touch these parts with bare
hands. Doing so can cause serious burns.
2) Lighting the
Ambiance Lantern
(fig. 3)
a) Move the lever (2) to the "-" position (towards the left).
b) Insert a lighted match in the opening near the lever
(2), at the bottom of the glass. Important: never insert
a match via the top of the glass.
c) Gradually open the gas by turning the control knob
(1) anti-clockwise.
3) during operation
Adjust the height of the flame by pivoting the lever (2)
towards the right ("+") for more flame or towards the left
("-") for less flame (Fig. 4).
The flame can also be adjusted by turning wheel (1) in
the "+" of "-" direction of the arrow. The flame should
ideally be between 4 and 5 cm high approximately (Fig.
10).
Important: Turn the wheel (1) or the lever (2) to reduce
the height of the flame if it extends beyond the glass.
4) Switching off
Close the tap by turning the control knob (1) clockwise
as far as it will go (direction "-" of the arrow) (fig. 5). Well
tighten the wheel to ensure that the gas is completely
turned off.
5) Ambiance perfume diffuser
Comply scrupulously with the precautions for use
supplied with the ambiance perfumes.
a - Setting in place
- Check that the gas inlet is closed properly by turning
the wheel (1) fully clockwise (arrow direction "-")
(Fig. 5).
- Wait for the lamp to cool down.
IFU 4010013592 - Ambiance Lantern EMEA.qxp 16/02/2011 09:34 Page 5
Содержание Ambiance Lantern
Страница 2: ...2 IFU 4010013592 Ambiance Lantern EMEA qxp 16 02 2011 09 34 Page 2 ...
Страница 39: ...39 AE IFU 4010013592 Ambiance Lantern EMEA qxp 16 02 2011 09 34 Page 39 ...
Страница 40: ...40 AE IFU 4010013592 Ambiance Lantern EMEA qxp 16 02 2011 09 35 Page 40 ...
Страница 42: ...IFU 4010013592 Ambiance Lantern EMEA qxp 16 02 2011 09 35 Page 42 ...
Страница 43: ...IFU 4010013592 Ambiance Lantern EMEA qxp 16 02 2011 09 35 Page 43 ...
Страница 44: ...IFU 4010013592 Ambiance Lantern EMEA qxp 16 02 2011 09 35 Page 44 ...