Appendix F. Datalogger Program Example
F-2
7: SDI-12 Recorder (P105)
1:
1
SDI-12 Address
2:
0
Start Measurement (aM0!)
3:
1
Port
4:
1
Loc [ BatVolts ]
5:
1.0
Mult
6:
0.0
Offset
8: Extended Parameters 4 Digit (P68)
1:
88
Option
;X
2:
83
Option
;S
3:
0000
Option
;End of command marker
4:
0000
Option
5:
0000
Option
6:
0000
Option
7:
0000
Option
8:
0000
Option
9: End (P95)
;IF THE BATTERY VOLTAGE DROPS BELOW 10.5 VDC THEN...
10: If (X<=>F) (P89)
1:
1
X Loc [ BatVolts ]
2:
4
<
3:
10.5
F
4:
30
Then Do
;EVERY 10 MINUTES...
11: If time is (P92)
1:
0
Minutes (Seconds --) into a
2:
10
Interval (same units as above)
3:
30
Then Do
;IMMEDIATELY BROADCAST "SITE 31, ALARM LOW BATTERY"
12: SDI-12 Recorder (P105)
1:
1
SDI-12 Address
2:
0
Start Measurement (aM0!)
3:
1
Port
4:
1
Loc [ BatVolts ]
5:
1.0
Mult
6:
0.0
Offset
13: Extended Parameters 4 Digit (P68)
1:
88
Option
;X
2:
84
Option
;T
3:
32
Option
;space
4:
83
Option
;S
5:
73
Option
;I
6:
84
Option
;T
7:
69
Option
;E
8:
32
Option
;space
Содержание Vospoder
Страница 4: ...This is a blank page ...
Страница 12: ...Section 1 Hardware 1 4 This is a blank page ...
Страница 36: ...Section 4 Vosponder Configuration and Programming 4 12 This is a blank page ...
Страница 50: ...Appendix D Terminal Commands Menu Tree D 2 This is a blank page ...
Страница 56: ...Appendix F Datalogger Program Example F 4 This is a blank page ...
Страница 57: ...This is a blank page ...