Safety

DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS,

TOWERS, AND ANY ATTACHMENTS TO TRIPODS AND TOWERS SUCH AS SENSORS, CROSSARMS, ENCLOSURES, ANTENNAS, ETC. FAILURE

TO PROPERLY AND COMPLETELY ASSEMBLE, INSTALL, OPERATE, USE, AND MAINTAIN TRIPODS, TOWERS, AND ATTACHMENTS, AND

FAILURE TO HEED WARNINGS, INCREASES THE RISK OF DEATH, ACCIDENT, SERIOUS INJURY, PROPERTY DAMAGE, AND PRODUCT FAILURE.

TAKE ALL REASONABLE PRECAUTIONS TO AVOID THESE HAZARDS. CHECK WITH YOUR ORGANIZATION'S SAFETY COORDINATOR (OR

POLICY) FOR PROCEDURES AND REQUIRED PROTECTIVE EQUIPMENT PRIOR TO PERFORMING ANY WORK.

Use tripods, towers, and attachments to tripods and towers only for purposes for which they are designed. Do not exceed design limits. Be

familiar and comply with all instructions provided in product manuals. Manuals are available at www.campbellsci.com. You are responsible

for conformance with governing codes and regulations, including safety regulations, and the integrity and location of structures or land to

which towers, tripods, and any attachments are attached. Installation sites should be evaluated and approved by a qualified engineer. If

questions or concerns arise regarding installation, use, or maintenance of tripods, towers, attachments, or electrical connections, consult

with a licensed and qualified engineer or electrician.

General

l

Protect from over-voltage.

l

Protect electrical equipment from water.

l

Protect from electrostatic discharge (ESD).

l

Protect from lightning.

l

Prior to performing site or installation work, obtain required approvals and permits. Comply with all governing structure-height

regulations.

l

Use only qualified personnel for installation, use, and maintenance of tripods and towers, and any attachments to tripods and

towers. The use of licensed and qualified contractors is highly recommended.

l

Read all applicable instructions carefully and understand procedures thoroughly before beginning work.

l

Wear a hardhat and eye protection, and take other appropriate safety precautions while working on or around tripods and towers.

l

Do not climb tripods or towers at any time, and prohibit climbing by other persons. Take reasonable precautions to secure tripod

and tower sites from trespassers.

l

Use only manufacturer recommended parts, materials, and tools.

Utility and Electrical

l

You can be killed or sustain serious bodily injury if the tripod, tower, or attachments you are installing, constructing, using, or

maintaining, or a tool, stake, or anchor, come in contact with overhead or underground utility lines.

l

Maintain a distance of at least one-and-one-half times structure height, 6 meters (20 feet), or the distance required by applicable

law, whichever is greater, between overhead utility lines and the structure (tripod, tower, attachments, or tools).

l

Prior to performing site or installation work, inform all utility companies and have all underground utilities marked.

l

Comply with all electrical codes. Electrical equipment and related grounding devices should be installed by a licensed and qualified

electrician.

l

Only use power sources approved for use in the country of installation to power Campbell Scientific devices.

Elevated Work and Weather

l

Exercise extreme caution when performing elevated work.

l

Use appropriate equipment and safety practices.

l

During installation and maintenance, keep tower and tripod sites clear of un-trained or non-essential personnel. Take precautions to

prevent elevated tools and objects from dropping.

l

Do not perform any work in inclement weather, including wind, rain, snow, lightning, etc.

Maintenance

l

Periodically (at least yearly) check for wear and damage, including corrosion, stress cracks, frayed cables, loose cable clamps, cable

tightness, etc. and take necessary corrective actions.

l

Periodically (at least yearly) check electrical ground connections.

Internal Battery

l

Be aware of fire, explosion, and severe-burn hazards.

l

Misuse or improper installation of the internal lithium battery can cause severe injury.

l

Do not recharge, disassemble, heat above 100 °C (212 °F), solder directly to the cell, incinerate, or expose contents to water. Dispose

of spent batteries properly.

WHILE EVERY ATTEMPT IS MADE TO EMBODY THE HIGHEST DEGREE OF SAFETY IN ALL CAMPBELL SCIENTIFIC PRODUCTS, THE CUSTOMER

ASSUMES ALL RISK FROM ANY INJURY RESULTING FROM IMPROPER INSTALLATION, USE, OR MAINTENANCE OF TRIPODS, TOWERS, OR

ATTACHMENTS TO TRIPODS AND TOWERS SUCH AS SENSORS, CROSSARMS, ENCLOSURES, ANTENNAS, ETC.

Содержание TX325

Страница 1: ...Revision 10 2020 Copyright 2019 2020 Campbell Scientific Inc...

Страница 2: ...6 1 Read and write settings 16 7 6 2 Read only settings 17 8 Troubleshooting 19 8 1 Troubleshooting over air transmissions 20 Appendix A Eligibility and getting onto the GOES system 23 Appendix B Dat...

Страница 3: ...Campbell Scientific FP2 data 33 B 2 2 Pseudobinary 38 B 2 3 Additional pseudobinary representations 38 B 3 Transmission durations 38 Appendix C Compliance documents and certificates 40 Table of Conten...

Страница 4: ...tion for many systems serving a wide range of applications 2 Precautions l READ AND UNDERSTAND the Safety section at the back of this manual l Although the TX325 is rugged it should be handled as a pr...

Страница 5: ...rectly connect your data logger to the Device Configuration Utility i Use the USB cable to connect the data logger to the computer ii Click your data logger model for the Device Type in the Device Con...

Страница 6: ...Type the Self timed Message Windows in seconds as assigned by the GOES DCS Program 8 Type the Platform ID in HEX as assigned by the GOES DCS Program 9 Select the Random Transmission Baud Rate as assig...

Страница 7: ...17 Click the Com Port Settings sub tab 18 Select 9600 for the Baud Rate 19 Click Apply to save the changes Now the settings are stored in the data logger CRBasic programming is required to push data o...

Страница 8: ...grooves should be placed at the spot on the boom with four dimples and so forth c Aim the Yagi antenna at the spacecraft azimuth and elevation angle positions are included on the bracket label 2 GPS a...

Страница 9: ...ot receive a GPS signal through steel roofs or steel walls Concrete might also be a problem Heavy foliage snow and ice will attenuate the GPS signal 3 Mount the TX325 the power supply and the data log...

Страница 10: ...lar panel cable through the enclosure conduit and connect the red and black wires to the CHG terminals on the CH150 or CH200 5 Overview The TX325 can transmit either self timed or random GOES messages...

Страница 11: ...ility l Embedded GPS receiver for stabilized internal time keeping and transmit frequency for long service intervals l Low standby current consumption for battery powered systems at remote DCP install...

Страница 12: ...only during a predetermined time frame typically 10 seconds every hour Random windows are for applications of a critical nature such as flood reporting and allow transmission immediately after a thres...

Страница 13: ...cm 6 25 x 5 9 x 1 8 in additional clearance required for cables wires and antennas Weight 0 77 kg 1 7 lb Supply voltage range 10 5 to 16 VDC Current drain at 12 VDC While transmitting 2 5 A 1 8 typic...

Страница 14: ...on without GPS fix 6 days Interface connectors RS 232 DB9 F DCE 3 wire RS 232 Satellite RF transmit out Type N jack GPS SMA jack Power 2 pin screw terminal 0 2 in pitch 7 Installation 7 1 Field site r...

Страница 15: ...n complete and ready to receive commands At power up blinks on and off three times Bootloader software is running Ready to load new operating system On continuously Transmitter failed to start up norm...

Страница 16: ...attaching the transmission antenna A properly matched antenna cable and antenna must be connected to the TX325 before transmission occurs WARNING Failure to use a properly matched antenna cable and a...

Страница 17: ...or example the element with four grooves should be placed at the spot on the boom with four dimples and so forth 7 5 GPS antenna The GPS antenna mounts to the end of a crossarm by using a 0 75 inch IP...

Страница 18: ...syntax GOESField NumVals Decimation Precision Width SHEF The NumVals is the number of historical values of the field to output For Decimation enter 1 to output every value enter 2 to output every oth...

Страница 19: ...signed by NESDIS Value is a string GOESRTBaudRate Baud rate for the random transmissions Valid settings are 100 300 or 1200 The baud rate must match the user s NESDIS channel assignment GOESRTChannel...

Страница 20: ...times within the random transmit interval that the TX325 will transmit the message data Valid entries are 1 to 3 7 6 2 Read only settings Table 7 5 Read only TX325 settings FieldName Description GOESi...

Страница 21: ...in view 11 no GPS position fix three usable GPS satellites in view GOESGPSAntennaStatus Status of the GPS antenna 0 GPS antenna is working 16 GPS antenna is not connected 48 GPS antenna is shorted GOE...

Страница 22: ...h is corrupt GOESCurrentTxState Current state of the radio 0 Idle 1 Transmission is in progress 2 Post transmission failsafe wait is in progress 8 Troubleshooting Issue TX325 is not transmitting First...

Страница 23: ...its microprocessor is reset causing the transmitter to reboot While in the fail safe mode the transmitter can communicate normally with the data logger but is unable to transmit again until the fail...

Страница 24: ...ress channels transmission times and window length Make sure your setting in your DCP match this information Failure to do so will result in loss of data and transmitting over the top of other DCP sch...

Страница 25: ...not the GPS time synched Table 8 1 p 22 This character is added to the number of bytes shown as LEN that were in the data transmission Table 8 1 Characters indicating time sync Character Data type Tim...

Страница 26: ...ing onto the GOES system 1 Follow the steps provided at https dcs2 noaa gov to submit an application for GOES DCS SUA Once submitted the approving authorities will review the application and notify yo...

Страница 27: ...can be used for self timed messages Several standard formats are selectable within CRBasic Formats not included can be easily formed using string formatted data fields allowing the content to be tailo...

Страница 28: ...9 9 0 1 120 0 7999 1 1200 NAN1 8190 INF2 8191 INF2 8191 1Not A Number 2Infinity Example output with 10 fields GoesTable Fields_Scan_Order FALSE Newest_First FALSE Format 1 GoesField Decimation 1 CR LF...

Страница 29: ...tabular format Columns are fixed width according to the field format and are space delimited Lines are CR LF delimited You can send either the newest or oldest data first A CR LF is added at the end...

Страница 30: ...ample outputs with 10 fields GoesTable Fields_Scan_Order FALSE Newest_First FALSE Format 2 GoesField Decimation 1 Precision 3 Width 4 CR LF 7 982 7 982 13 1 25 8 CR LF GoesTable Fields_Scan_Order FALS...

Страница 31: ...R LF 8 31 13 14 26 74 CR LF 8 30 13 14 26 74 CR LF 8 29 13 14 26 74 CR LF GoesTable Fields_Scan_Order TRUE Newest_First FALSE Format 2 GoesField Decimation 1 Precision 3 Width 5 SHEF set to HG TA VB C...

Страница 32: ...le if Scan_Order is set to False l Each line has all data from a single sensor if Scan_Order is set to True l SHEF Codes can be added as headers or at the beginning of lines using GOESField option SHE...

Страница 33: ...26 24 CR LF GoesTable Fields_Scan_Order FALSE Newest_First FALSE Format 3 GoesField Decimation 1 Precision 3 Width 5 SHEF set to HG TA VB CR LF HG TA VB CR LF 7 94 13 13 26 72 CR LF GoesTable Fields_S...

Страница 34: ...that is human readable l NANs INFs INFs and missing values show as forward slashes in the output l LABEL is the SHEF code two character parameter Refer to https dcs1 noaa gov documents SHEF 20Codes p...

Страница 35: ...n 15 minutes prior to transmission 13 18 Sensor or measurement reading taken 30 minutes prior to transmission 13 19 Sensor or measurement reading taken 45 minutes prior to transmission TA SHEF Code TA...

Страница 36: ...ncoded unsigned integer 0 to 63 1 byte encoded signed integer 32 to 31 2 byte encoded unsigned integer 0 to 4094 2 byte encoded signed integer 2048 to 2047 3 byte encoded unsigned integer 0 to 262143...

Страница 37: ...the magnitude of the 13 bit mantissa 0 to 8191 Table B 7 Calculation of finished value Sign S Exponent E Mantissa M FP2 value equals 0 00 8191 INF 1 00 8191 INF 1 00 8190 NAN 0 or 1 00 or 01 or 10 0 t...

Страница 38: ...b8 b7 p 1 b6 b5 b4 b3 b2 b1 0 1 0 0 0 1 1 0 0 1 0 1 0 0 1 1 0 1 0 1 0 0 1 0 Table B 10 Encoding of 12 34 Character 1 D Character 2 S Character 3 R Sign Exponent Mantissa Mantissa Mantissa p 1 0 0 b16...

Страница 39: ...b8 b7 p 1 b6 b5 b4 b3 b2 b1 0 1 0 0 1 0 0 0 0 1 0 1 0 0 1 1 0 1 0 1 0 0 1 0 Table B 14 Encoding of 1 234 Character 1 N Character 2 S Character 3 R Sign Exponent Mantissa Mantissa Mantissa p 1 0 0 b16...

Страница 40: ...b10 b9 b8 b7 p 1 b6 b5 b4 b3 b2 b1 0 1 0 0 1 1 1 0 0 1 0 0 0 0 0 1 0 1 1 1 1 0 1 1 Table B 18 Encoding of INF Character 1 A Character 2 Character 3 Sign Exponent Mantissa Mantissa Mantissa p 1 0 0 b1...

Страница 41: ...elevation of 123 45 ft can be multiplied by 100 to get an integer of 12345 This integer is stored for transmission with the encoding shown in Table B 21 p 38 Table B 21 Example encoding of water level...

Страница 42: ...23 N 4 600 Random 1200 bps 223 N 4 600 Table B 23 GOES self timed message maximum data bytes and assigned time slot duration Assigned time slot duration seconds GOES 300 bps maximum data per message b...

Страница 43: ...6370 Lusk Blvd Suite F206 San Diego California 92121 United States has been assessed by NSF ISR and found to be in conformance to the following standard s ISO 9001 2015 Scope of Registration Engineer...

Страница 44: ...ts technical performance as specified in the certification standards for this type of equipment recertification of this model shall be required before placing in operation In accordan ce w ith Ver5ion...

Страница 45: ...ther manufacturer s products that are resold by Campbell Scientific are warranted only to the limits extended by the original manufacturer Refer to www campbellsci com terms warranty for more informat...

Страница 46: ...ion or Repair Reference number contact your CAMPBELL SCIENTIFIC regional office Please write the issued number clearly on the outside of the shipping container and ship as directed For all returns the...

Страница 47: ...rohibit climbing by other persons Take reasonable precautions to secure tripod and tower sites from trespassers l Use only manufacturer recommended parts materials and tools Utility and Electrical l Y...

Страница 48: ...nfo campbellsci fr www campbellsci fr Germany Location Phone Email Website Bremen Germany 49 0 421 460974 0 info campbellsci de www campbellsci de India Location Phone Email Website New Delhi DL India...

Отзывы: