T107 Weather Station
FIGURE 2-25. Short-haul modem mounting and connection
2.5.3.1 Internal Installation
If the short haul modem was ordered with the T107, you can skip
this section and go directly to Section 2.5.3.2,
External
Installation
.
For installation inside the ET Enclosure, the following components are
provided in the short-haul modem kit:
(1) Part number 10596 (SC932C) 9-pin to RS-232 DCE Interface
(1) Rad Modem
(1) Rad/SC932C Mounting Bracket
(1) 12 inch 4-wire patch cable
NOTE
Rad Short
Haul Modem
SC932C
12” 4-Wire
Patch Cable
(see Figure
2.5-4 for
wiring)
10588 Ribbon Cable
(see Figure 2.5-4 for
wiring)
34